Heat & Glo LifeStyle TIARAP-CES, TIARAP-CTO Intake Damper Operation Positioning the Logs

Page 32

D. Intake Damper Operation

F. Positioning the Logs

The intake damper can be used with or without the flue restrictor to adjust the air flow. Opening the damper makes the flames shorter and more active. Closing the damper makes the flames taller and less active.

Figure 8.6 Loosen the wingnut that secures the damper. The wingnut is located on the underside of the appliance, to the right of the pilot assembly.

To CLOSE the intake damper, pull the wingnut forward.

To OPEN the damper, push the wingnut back. Adust the damper in 1/4 in. increments until the desired flame is achieved. After adjustment, tighten the wingnut.

NOTE: In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor.

E. Intake Air Shutter Adjustment

OPENCLOSE

Figure 8.7 The shutter is located on the underside of the appliance, on the right side. To adjust the shutter, loosen the wingnut.

Moving the shutter bolt to the right closes the shutter. Moving the shutter bolt to the left, will open the shutter. Opening the shutter causes flames to become shorter and blue. Closing the shutter creates taller orange/yellow flames.

NOTE: Do not close so much as to cause a sooty flame. Improper adjustment can cause sooting in the firebox and/ or on the outside of a house with a horizontal termination.

Retighten the wingnut after adjustment.

While still breakable, the logs do not become fragile until after the appliance is burned and they have cured. After curing, any handling must be done with care as breakage can easily occur.

PLEASE NOTE: Logs have been designed to work specifically with the burner of this appliance. Exact placement will ensure proper operation of your gas appliance and reduce sooting.

Figure 8.8 Gently remove the top of the appliance and set aside. Remove the cast face by sliding straight up and set it aside.

Remove the glass by releasing the latch located on the top of the appliance. Lean the glass frame forward and lift it out.

Place the left log on the log shelf along the back of the firebox with thefront resting on the burner.

Figure 8.9 Place the right log on the log shelf along the back of the firebox with the front of the log resting on the burner.

Page 32

Heat & Glo · Tiara Petite B · 7026-101K

August 1, 2008

Image 32
Contents Hot glass will cause burns Installation and OperationWhat to do if you smell gas Congratulations Location Hang tag attached to rear of applianceTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Design & Installation Considerations Getting StartedTools and Supplies Needed Inspect Appliance & ComponentsClearances to Combustibles Appliance Location and ClearancesSelecting Appliance Location 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting GuidelinesHorizontal Termination Step203mm Vinyl Siding Vertical Termination Direct Vent PipeCeiling Joists Framing 2 in mm Long Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Level Cathedral Ceiling Support BoxClass a Metal Chimney Type C Up & Out Installation Type a & B Co-Axial to Co-LinearExisting Masonry Chimney Type D Hearth MountCut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Installing Slim Line Trim Ring and Heat Shield Slim Line Wall ThimbleAssembling Slim Line Trim Ring and Heat Shield NextFIG. C Minimum Clearance Wire clip Gas InformationFuel Conversions Converting to LP GasValve Regulator Replacement Screws Rubber Gasket Identification Label FGas Pressures Gas ConnectionHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthIgnition Module Access and Battery Replacement To access the moduleLeg Leveling System Appliance SetupRemove Shipping Materials Flue Restrictor Installation Intake Air Shutter Adjustment Intake Damper Operation Positioning the LogsAccessories Mineral WoolBlower Installation KIT ContentsAugust 1 Heat & Glo · Tiara Petite B · 7026-101K 19 Complete Assembly Warming Shelves Installation Glass ReplacementControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram SL-D Series Vent ComponentsVent Components List HHT SL-PTermination Caps & Kits Tiara Petite B DescriptionService Parts List cont’d. Tiara Petite B Tiara Petite B Cast Parts Individual Pieces Accessories Service and Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsDealer Telephone Tiara Petite BContact Information