Thermopile
Ignition Module
Black
ON/OFF
Switch
BlackTH
IgniterPilot | Thermocouple |
Gas |
|
PILOT ASSEMBLY
|
| TPTH |
|
| TP |
| |
TPTH |
| A | E |
|
|
| |
TP |
|
|
|
TH | HI | LO |
|
| N | O | |
|
| O | F |
|
|
| F |
|
|
| TOLIP |
| P |
|
|
| TOLI |
|
|
VALVE
Figure 7.1
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
CAUTION
Shock hazard.
•Replace damaged wire with type 105O C rated wire.
•Wire must have high temperature insulation.
D.Ignition Module Access and Battery Replacement
The Ignition Module is located under the appliance attached to the decorative cover.
To access the module:
1.Lift off the appliance top and place it on a flat surface, with the porcelain side up to prevent damage.
2.Remove the appliance front by sliding it upwards in the grooves, being careful not to chip the porcelain. Lay the front face up on a flat surface.
3.With the cast iron front removed, remove the decorative cover located under the apliance. To remove the cover, remove the two screws on the front of the appliance that hold the cover in place. Pull the cover forward, down and out. The module will then be accessible for service and battery replacement.
The single "AA" 1.5V battery that powers the ignitor is located in the module. To replace the battery, open the battery compartment and remove the old battery. Replace the battery making sure the polarity is correct.
Figure 7.2
CAUTION
Battery polarity must be correct or module damage will occur.
Page 30 | Heat & Glo · Tiara Petite B · | August 1, 2008 |