Heat & Glo LifeStyle TIARAP-BK Operating Instructions, Before Lighting Appliance, Controls

Page 38

9 Operating Instructions

A. Before Lighting Appliance

Read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, bodily injury, or even death.

Remove all shipping materials from inside and/or underneath the firebox.

Review proper placement of logs, mineral wool.

Check the wiring.

Check the baffle adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper posi- tion.

Ensure that the flow of combustion and ventilation air is not obstructed (front grilles and vent caps).

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

WARNING

Glass door must be in place when appliance is operating.

Risk of:

Combustion Fumes

Fire

Do NOT operate appliance with glass door removed.

Open viewing glass for servicing only.

Glass door MUST be in place and sealed before operating appliance.

Only use glass door certified for use with appliance.

Glass replacement should be done by qualified technician.

WARNING

HOT! DO NOT TOUCH.

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

Glass and other surfaces are hot during operation and cool down.

Keep children away.

CAREFULLY SUPERVISE children in same room as appliance.

Alert children and adults to hazards of high temperatures.

Do NOT operate with protective barriers open or removed.

Keep clothing, furniture, draperies and other combustibles away.

B. Controls

FAN SPEED: The blower is optional installed on the appliance and this knob controls the speed of the blower that pushes the heated air into the room.

MAIN BURNER: This control is used to turn the appliance on and off.

PILOT IGNITOR: The pilot ignitor is used only to start the pilot. When the valve control knob is turned to the pilot position and fully depressed, it sends an electrical charge to the pilot assembly. The appliance is equipped with an electric igniter and should begin sparking right away.

VALVE CONTROL: This knob is used to control gas to the appliance and for starting the pilot. There are three positions, ON, OFF, & PILOT. The indicator on the valve indicates the position of the knob.

COMFORT CONTROL: This knob controls the flame height from low (“LO”) to high (“HI”).

NOTE: If using a remote control wall switch, or thermostat, the On/Off Switch must be left “OFF”. Turning the On/Off Switch to “ON” will keep the appliance on continually.

Page 38

Heat & Glo · Tiara Petite B · 7026-101K

August 1, 2008

Image 38
Contents Hot glass will cause burns Installation and OperationWhat to do if you smell gas Congratulations Location Hang tag attached to rear of applianceTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Tools and Supplies Needed Design & Installation ConsiderationsGetting Started Inspect Appliance & ComponentsClearances to Combustibles Appliance Location and ClearancesSelecting Appliance Location 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsHow to Use the Vent Graph Venting GuidelinesHorizontal Termination Step203mm Vinyl Siding Vertical Termination Direct Vent PipeCeiling Joists Framing 2 in mm Long Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Level Cathedral Ceiling Support BoxClass a Metal Chimney Existing Masonry Chimney Type C Up & Out InstallationType a & B Co-Axial to Co-Linear Type D Hearth MountCut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble NextFIG. C Minimum Clearance Fuel Conversions Wire clipGas Information Converting to LP GasValve Regulator Replacement Screws Rubber Gasket Identification Label FGas Pressures Gas ConnectionHigh Altitude Installations Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthIgnition Module Access and Battery Replacement To access the moduleLeg Leveling System Appliance SetupRemove Shipping Materials Flue Restrictor Installation Intake Air Shutter Adjustment Intake Damper Operation Positioning the LogsAccessories Mineral WoolBlower Installation KIT ContentsAugust 1 Heat & Glo · Tiara Petite B · 7026-101K 19 Complete Assembly Warming Shelves Installation Glass ReplacementControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram SL-D Series Vent ComponentsVent Components List HHT SL-PTermination Caps & Kits Tiara Petite B DescriptionService Parts List cont’d. Tiara Petite B Tiara Petite B Cast Parts Individual Pieces Accessories Service and Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsDealer Telephone Tiara Petite BContact Information