STEP 7.
LOG #6 (SRV2107-706):
Place notch of log #6 over the left grate tine. Log should rest on the flat of log #5 and the flat on log #3. You may need to reposition log #5 to get log #6 to sit in the flats. See Figure 12.18.
6
Figure 12.18
F. Glass Assembly
WARNING
Handle glass doors with care.
•Inspect the gasket to ensure it is undamaged.
•Inspect the glass for cracks, chips or scratches.
•Do NOT strike, slam or scratch glass.
•Do NOT operate appliance with glass door removed, cracked, broken or scratched.
•Replace glass door assembly as a complete appliance.
Removing Glass Assembly
Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 12.19).
Replacing Glass Assembly
Replace the glass door on the appliance. Pull out and latch the four glass assembly latches into the groove on the glass frame.
LATCHES |
(BOTH BOTTOM |
AND TOP) |
GLASS |
ASSEMBLY |
Figure 12.19 Glass Assembly |
G. Grilles and Trim
Install optional marble and brass trim surround kits as de- sired. Marble, brass, brick, tile, or other noncombustible materials can be used to cover up the gap between the sheet rock and the appliance.
Do not obstruct or modify the air inlet/outlet grilles. When overlapping on both sides, leave enough space so that the bottom grille can be lowered and the trim door removed.
H. Air Shutter Setting
This appliance has an adjustable air shutter (which con- trols the primary air) factory set for the minimum vertical vent run. If your installation has more than the minimum required vertical vent length, adjustment of the air shutter may be necessary to obtain optimal flame appearance.
This should be adjusted by a qualified installer at in- stallation.
To adjust air shutter, loosen the wing nut. Close air shutter by pushing the air shutter forward. Care should be taken when adjusting the air shutter so as not to cause the ap- pliance to soot. If sooting occurs the air shutter will need to be opened by pulling the air shutter forward.
Shutter Settings
Burner | NG | LP |
| Full Open | Full Open |
| Full Open | Full Open |
| AIR SHUTTER |
TOP OF | WING NUT |
FIREPLACE |
|
| FIREBOX SUPPORT |
| BASE |
| BOTTOM OF FIREPLACE |
Figure 12.20 | WITH BOTTOM TRAY REMOVED |
|
44 | Heat & Glo • |