B. Vent Components Diagrams

 

Pipe

Effective Length

10-1/2 in.

 

Effective

Inches

Millimeters

(267 mm)

45°

 

Height/Length

DVP4

4

102

 

 

 

DVP6

6

152

 

 

 

DVP12

12

305

4-7/8 in.

 

 

DVP24

24

610

( 276 mm)

 

 

 

10-7/8 in.

 

DVP36

36

914

 

DVP Pipe (see chart)

 

(276 mm)

DVP48

48

1219

DVP45 (45 Elbow)°

 

 

DVP6A

3 to 6

76 to 152

 

 

 

 

DVP12A

3 to 12

76 to 305

 

 

 

DVP12MI

3 to 12

76 to 305

 

 

 

DVP24MI

3 to 24

76 to 610

 

 

 

 

 

 

 

11-3/8 in.

 

 

 

 

 

(289 mm)

10 in.

 

 

 

 

 

(254 mm)

10 in.

1 in.

 

 

 

(254 mm)

 

 

 

(25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

7-3/8 in.

24 in.

 

 

 

 

(187 mm)

 

 

 

 

 

(610 mm)

 

 

 

 

1-1/4 in. (32 mm)

 

 

 

 

 

 

 

 

 

9-1/4 in.

 

 

 

 

 

(235 mm)

1/2 in. TYP

 

 

 

 

13-1/4 in.

(13 mm)

 

 

 

 

 

 

 

 

 

(337 mm)

 

DVP-AS (Attic Shield)

DVP-FS (Ceiling Firestop)

DVP90ST (90° Elbow)

 

 

 

 

 

 

 

 

12 in.

1 in.

 

 

 

 

(305 mm)

(25 mm)

10 in.

1- 1/2 in.

 

 

 

8 in.

 

 

 

(203 mm)

(254 mm)

(38 mm)

 

14 in.

 

 

 

 

 

 

 

UP

 

 

(356 mm)

 

 

 

 

 

 

5 in.

12 in.

 

 

 

 

(127 mm)

(305 mm)

 

 

 

 

 

 

 

 

6 in.

 

 

 

 

 

(152 mm)

 

DVP-HVS (Vent Support)

 

 

DVP-WS (Wall Shield Firestop)

Figure 16.2 DVP vent components

 

 

 

 

 

 

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. H • 11/08

53

Image 53
Contents What to do if you smell gas ModelsModel Number Serial Number Homeowner Reference InformationTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Read all of the instructions before starting the instaInspect Firebox Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance Chase724 425 406 279 Mantel ProjectionsHearth Extension Hearth Extension DimensionsVent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Alcove ApplicationsContinue Adding Vent Components Install Support BracketsTo Install the Heat Shield Vent Table Key Vent Information and DiagramsMeasuring Standards Use of ElbowsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow Top Vent Vertical Termination Straight up Vertical Venting Top Vent Horizontal Termination Three ElbowsV1 = 50 ft. Max .2 m 152 mm 914 mm 305 mm 610 mm 10 ft305 mm 610 mm 914 mm 10 ft Top Vent Horizontal Termination Two ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Appliance Preparation Removing Non-combustible Facing Mate- rial AssemblySecuring and Leveling the Appliance Installing Non-combustible Facing MaterialComplete Installation of Non-combustible Facing Material Installing Flue RestrictorsAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Disassembly of Vent SectionsVertical Sections Horizontal SectionsInstalling the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Heat shield DVP-HSM-B must be usedflue of the pipe see Figure Installing Roof Flashing and Vertical Ter- mination Cap18 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarGas Pressures Gas InformationFuel Conversions Gas Connection High Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Electrical InformationFor units Without factory installed Rocker Switch Junction Box InstallationStep Finishing Non-combustible Facing Material Facing MaterialFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material OptionsFinishing Material Thickness greater than 1-1/4 inch Mounting stone eye brow ATRIMSTONE-36, ATRIMSTONE-4210 Fireplace sitting on combustible surface Clean the Appliance Appliance SetupAccessories Ember PlacementPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36Heat & Glo Cerona-36, Cerona-42 2106-900 Rev. H 11/08 Model Cerona-42 Step Grilles and Trim Glass AssemblyAir Shutter Setting This appliance has an Intellifire ignition system Operating InstructionsBefore Lighting Appliance Final inspection by Lighting Appliance IPI IgnitionAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksModel Cerona-36 Model Cerona-42 Appliance Dimension DiagramReference Materials DVP vent components Vent Components DiagramsDVP-TRAP COOL-ADD Not for use with these models Part number list on following Log Set AssemblyService Parts At Depot Service Parts ListStocked IPI Valve Assembly CERONA-42 Touch UP Paint -Fiber box LOGS-CERONA42IPI Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information