Hearth and Home Technologies CERONA-42 owner manual Not for use with these models

Page 56

B. Vent Components Diagrams (continued)

 

 

7-1/4 in.

 

 

 

 

(184 mm)

 

12-1/2 in.

 

 

 

 

 

 

 

 

(318 mm)

 

 

5-1/4 in.

 

 

 

 

(133 mm)

 

 

 

PVK-80

 

DVP-TVHW

 

(For use with IPI and DSI appliances only.)

 

 

 

 

VerticalTermination Cap (Highwind)

 

 

 

 

7-1/4 in.

 

16-7/8 in.

14 in.

1 in.

(184 mm)

 

(25 mm)

 

 

(429 mm)

(356 mm)

 

 

12 in.

 

 

14 in.

 

(305 mm)

 

 

(356 mm)

 

12-1/8 in.

7-1/8 in.

 

 

 

(181 mm)

 

 

 

(314 mm)

 

 

3/8 in. (10 mm)

 

 

 

 

8-3/4 in.

 

1 in. (25 mm)

 

 

 

 

 

(222 mm)

 

 

7-3/4 to 10-3/8 in.

 

 

 

 

 

 

 

 

(197 to 264 mm)

 

1-5/8 in.

 

 

 

 

(41 mm)

 

 

DVP-FBHT

 

 

 

 

FireBrickTermination Cap

 

DVP-HPC

 

 

 

 

High Performance Cap

 

 

 

 

 

 

 

3-7/8 in.

 

 

 

 

(98 mm)

 

 

 

 

10-1/2 in.

 

 

 

 

(267 mm)

 

 

 

 

DVP-TV

 

 

 

VerticalTermination Cap

 

 

 

Not for use with these models

Figure 16.5 DVP vent components

 

 

 

56

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. H • 11/08

 

Image 56
Contents Models What to do if you smell gasHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Read all of the instructions before starting the instaInspect Firebox Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections 724 425 406 279Hearth Extension Dimensions Hearth ExtensionTermination Locations Vent Termination Minimum ClearancesAlcove Applications Minimum Clearances for TerminationContinue Adding Vent Components Install Support BracketsTo Install the Heat Shield Vent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow Top Vent Horizontal Termination Three Elbows Top Vent Vertical Termination Straight up Vertical VentingV1 = 50 ft. Max .2 m 152 mm 914 mm 305 mm 610 mm 10 ftTop Vent Horizontal Termination Two Elbows 305 mm 610 mm 914 mm 10 ftVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Removing Non-combustible Facing Mate- rial Assembly Appliance PreparationInstalling Non-combustible Facing Material Securing and Leveling the ApplianceInstalling Flue Restrictors Complete Installation of Non-combustible Facing MaterialInstalling Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections Securing the Vent SectionsVertical Sections Horizontal SectionsInstalling Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Heat shield DVP-HSM-B must be usedInstalling Roof Flashing and Vertical Ter- mination Cap flue of the pipe see FigureAssembling and Installing Storm Collar 18 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection High Altitude Installations Recommendation for Wire Intellifire Ignition System WiringConnecting to the Appliance Electrical InformationJunction Box Installation For units Without factory installed Rocker SwitchStep Finishing Facing Material Non-combustible Facing MaterialFinishing Material Options Finishing Material Thickness from 3/4 in. to 1-1/4Finishing Material Thickness greater than 1-1/4 inch Mounting stone eye brow ATRIMSTONE-36, ATRIMSTONE-4210 Fireplace sitting on combustible surface Appliance Setup Clean the ApplianceAccessories Ember PlacementLog Assembly LOGS-Cerona36 Positioning the Logs Model Cerona-36Heat & Glo Cerona-36, Cerona-42 2106-900 Rev. H 11/08 Model Cerona-42 Step Grilles and Trim Glass AssemblyAir Shutter Setting This appliance has an Intellifire ignition system Operating InstructionsBefore Lighting Appliance Lighting Appliance IPI Ignition Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsModel Cerona-36 Model Cerona-42 Appliance Dimension DiagramReference Materials Vent Components Diagrams DVP vent componentsDVP-TRAP COOL-ADD Not for use with these models Part number list on following Log Set AssemblyService Parts At Depot Service Parts ListStocked IPI Valve Assembly CERONA-42 LOGS-CERONA42 Touch UP Paint -Fiber boxIPI Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information