Service Parts List

CERONA-42

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

Stocked

parts for your appliance please provide model number and serial number. All parts listed

 

in this manual may be ordered from an authorized dealer.

 

 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

 

Log Set Assembly

 

LOGS-CERONA42

Y

1

Log 1

 

SRV2107-701

 

2

Log 2

 

SRV2107-702

 

3

Log 3

 

SRV2107-703

 

4

Log 4

 

SRV2107-704

 

5

Log 5

 

SRV2107-705

 

6

Log 6

 

SRV2107-706

 

7

Top Header Heat Shield

 

2107-144

 

8

Bottom Header Heat Shield

 

2107-145

 

9

Non-Combustible Board

 

2107-030

 

10

Burner NG, LP

 

2107-003

Y

11

Grate Assembly

 

2106-006

 

12

Glass Door Assembly

 

GLA-CERONA42

Y

13

Fan Kit

 

GFK-160A

 

14

Junction Box

 

4021-013

Y

 

Control Box

Pre SN #0021358908

2106-025

Y

 

Post Sn #0021359354

WSK-MLT

 

 

 

 

 

Fiber Patch Kit

 

SRV-PACK

 

 

Fiberglass Rope

 

060-455

 

 

Glass Latch Assembly

 

386-122A

Y

 

Mineral Wool

 

050-721

 

 

On/Off Rocker Switch

 

060-521A

Y

 

Screw Bag (23 ea)

 

2062-110-23

Y

 

Solenoid - 110 Volt Hi/Lo

 

2101-029

Y

 

Touch Up Paint

 

TUP-GBK-12

 

 

Touch UP Paint -Fiber box

 

CERONA-PAINT

 

 

Vermiculite Embers

 

MYSTIC-EMBERS

 

 

Vertical Restrictor

 

2106-141

 

 

Wall Control Assembly

 

2106-072

Y

 

Wires, 2 in Male to Male

 

2012-206

 

 

Wire, Wall Switch

 

2095-550

Y

 

 

 

 

 

 

Conversion Kit NG

 

N/A

 

 

Conversion Kit LP

 

LPK-CERONA42

Y

 

Pilot Orifice NG

 

593-528

Y

 

Pilot Orifice LP

 

593-527

Y

 

Regulator NG

 

NGK-DXV

Y

 

Regulator LP

 

LPK-DXV

Y

Additional service part numbers appear on following page.

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. H • 11/08

61

Image 61
Contents What to do if you smell gas ModelsModel Number Serial Number Homeowner Reference InformationTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Read all of the instructions before starting the instaInspect Firebox Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance Chase724 425 406 279 Mantel ProjectionsHearth Extension Hearth Extension DimensionsVent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Alcove ApplicationsTo Install the Heat Shield Install Support BracketsContinue Adding Vent Components Vent Table Key Vent Information and DiagramsMeasuring Standards Use of ElbowsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows Top Vent Vertical Termination Straight up Vertical Venting Top Vent Horizontal Termination Three ElbowsV1 = 50 ft. Max .2 m 152 mm 914 mm 305 mm 610 mm 10 ft305 mm 610 mm 914 mm 10 ft Top Vent Horizontal Termination Two ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Mate- rial AssemblySecuring and Leveling the Appliance Installing Non-combustible Facing MaterialComplete Installation of Non-combustible Facing Material Installing Flue RestrictorsAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Disassembly of Vent SectionsVertical Sections Horizontal SectionsInstalling the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Heat shield DVP-HSM-B must be usedflue of the pipe see Figure Installing Roof Flashing and Vertical Ter- mination Cap18 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures High Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Electrical InformationFor units Without factory installed Rocker Switch Junction Box InstallationStep Finishing Non-combustible Facing Material Facing MaterialFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material OptionsFinishing Material Thickness greater than 1-1/4 inch Mounting stone eye brow ATRIMSTONE-36, ATRIMSTONE-4210 Fireplace sitting on combustible surface Clean the Appliance Appliance SetupAccessories Ember PlacementPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36Heat & Glo Cerona-36, Cerona-42 2106-900 Rev. H 11/08 Model Cerona-42 Step Air Shutter Setting Glass AssemblyGrilles and Trim Before Lighting Appliance Operating InstructionsThis appliance has an Intellifire ignition system Final inspection by Lighting Appliance IPI IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramModel Cerona-36 Model Cerona-42 DVP vent components Vent Components DiagramsDVP-TRAP COOL-ADD Not for use with these models Service Parts Log Set AssemblyPart number list on following Stocked Service Parts ListAt Depot IPI Valve Assembly CERONA-42 Touch UP Paint -Fiber box LOGS-CERONA42IPI Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information