A. Maintenance Tasks

Inspect

 

Maintenance Tasks

Doors

1.

Inspect for scratches, dents or other damage and repair as necessary.

 

2.

Verify no obstructions to air flow.

 

3.

Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

2.

Inspect glass for scratches and nicks that can lead to breakage when exposed to heat.

 

3.

Confirm there is no damage to glass or glass frame, Replace as necessary.

 

4.

Verify that latches engage properly and glass attachment components are intact and operat-

 

ing properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be

 

removed.

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these

and Firebox Top

areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

3.

Verify unobstructed air circulation.

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as neces-

 

sary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as neces-

 

sary.

 

2.

Replace appliance if firebox has been perforated.

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

 

necessary. USE CAUTION WHEN CLEANING/HANDLING CERAMIC BURNER.

 

3.

Replace ember material with new dime-size and shape pieces. Do not block ports or obstruct

 

lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

5.

Inspect for lifting and other flame problems.

 

6.

Inspect orifice for soot, dirt or corrosion.

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

9.

Inspect thermocouple/thermopile sensor rod for soot, corrosion and deterioration. Clean with

 

emery cloth or replace as required.

 

10. Verify millivolt output. Replace as necessary.

Venting

1.

Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks,

 

fences or sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

 

5.

Verify weather stripping, sealing and flashing remains intact.

Remote Controls

1.

Verify operation of remote.

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

 

 

Page 40

Quadra-Fire • Hudson Bay • 7003-121 Rev. i

10/08

Image 40
Contents Do not Discard this Manual What to do if you smell gasDo Discardnot Welcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Design & Installation Considerations Tools will apply to every installationGetting Started Inspect Appliance & ComponentsSelecting Appliance Location Appliance Location and ClearancesClearances 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Vertical Distance from Appliance to to the 90 ElbowHorizontal Termination StepCenter Hole Line Wallcenter Thimbleline Fold Strap Here Sheet Metal Screw Direct Vent Pipe Vertical TerminationStep Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Retro Connector Fuel Conversions Gas InformationConverting to LP Gas Valve Regulator Replacement Remove pilot hood and set asideGas Pressures PressureGas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthRED 28 711 MM ValveAppliance Setup AccessoriesDoor Crown Installation Remove Shipping MaterialsGrille Installation Brick Set InstallationPositioning the Logs 13 Log SetMineral Wool Blower Installation 23 Blower Wiring DiagramDamper Adjustment Shutter AdjustmentGlass Replacement Door Frame with Glass Assembly ReplacementBefore Lighting Appliance Operating InstructionsControls For Your Safety Read Before Lighting Lighting ApplianceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram SLP Series Vent ComponentsVent Components List MiscellaneousRD. Service Parts List Stocked At DepotValve Components Pedestal Components DepotDescription Serial # Part Number CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Serial Number Date Purchased Date Installed Dealer Telephone Hudson Bay Direct Vent Gas Appliance