Top Vent - Vertical Termination
No Elbow
Note: Use SLP Series components only.
Note: If installing a vertical vent/termination off the top of the appliance, the optional vertical termination baffle may be needed.
V1 = 60 ft. Max. (18.3 m) |
V1 |
Figure 7.7 |
Exhaust restrictors are recommended for these verti- cally terminated products which have excessive draft. Exhaust restrictors will compensate for high draft, and restore visual flame height. If the vent configuration has a total vertical of
Exhaust restrictor Instructions
1.Install the exhaust restrictor over the center of the ex- haust outlet in the firebox (see Figure 7.8).
2.Center the exhaust restrictor in the open end of the exhaust outlet and secure through the slots on the ex- haust restrictor with the
INNER HEAT SHIELD
To access the exhaust openings, remove the inner heat shield. To remove inner heat shield, remove the two screws.
Top Vent Application
Exhaust restrictor
Rear Vent Application
Exhaust restrictor
Note: Be sure to re- install the inner heat shield after exhaust restrictor installation.
Figure 7.8