Hearth and Home Technologies QV36B-A, QV32B-A owner manual Listing and Code Approvals

Page 7

1 Listing and Code Approvals

A. Appliance Certification

MODELS: QV32B-A, QV36B-A

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Direct Vent Gas Fireplace Heater

STANDARD: ANSI Z21.88-2005CSA2.33-2005

This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.

NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

B. Tempered Glass Specifications

Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as defined by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectur- al Testing, Inc. Reports 02-31919.01and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Sec- tion 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.

C. BTU Specifications

Models

 

Maximum

Minimum

Orifice

 

Input

Input

U.S. (0-2000 ft.) or Canada (2000-4500 ft.)

BTU/h

BTU/h

Size (DMS)

QV32B-A (NG)

US

28,000

17,000

38

CANADA

25,200

15,300

39

 

QV32B-A (LP)

US

26,300

15,000

1.55 mm

CANADA

23,670

13,500

53

 

QV36B-A (NG)

US

30,000

20,500

36

CANADA

27,000

18,450

37

 

QV36B-A (LP)

US

28,000

15,800

52

CANADA

25,200

14,220

53

 

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Check with your local gas utility to determine proper orifice size.

E. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763 shall be considered non-combustible materials.

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Quadra-FireQV32B-A, QV36B-A2014-900 Rev. U • 1/12

7

Image 7
Contents What to do if you smell gas ModelsHOT Surfaces Homeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalFinal inspection by Lighting Instructions Standing PilotWhat to do if YOU Smell GAS Issue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseModels Combustible Mantels Mantel and Wall ProjectionsCombustible Mantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsOpening Minimum Clearances for Termination Covered Alcove ApplicationsUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyClearance Use of Flex VentMinimum Maximum Top Vent Horizontal Termination Venting with 1 elbow PropaneV1 Minimum H1 + H2 Maximum Venting with 2 elbows NG Venting with 2 elbows PropaneMinimum + H 2 Maximum Top Vent Horizontal Termination Venting with 3 elbows NGExhaust restrictor Instructions Top Vent Vertical Termination No Elbow = 60 ft. Max .3 mV1 Minimum H1 Maximum V1 + V2 Minimum Top Vent Vertical Termination Venting with 2 elbows NGTop Vent Vertical Termination Venting with 2 elbows Propane Minimum Maximum + V 2 MinimumTop Vent Vertical Termination Venting with 3 elbows Propane Top Vent Vertical Termination Venting with 3 elbows NGV1 Min H1 Max V2 Min H2 Max V3 Min Top Vent Vertical Termination Four 90º ElbowsH1 + H2 MAX H1 MAX V1 MIN H2 MAXMIN MAX Rear Vent Horizontal Termination Venting with 3 elbowsRear Vent Vertical Termination Venting with 1 elbow H1 + H2 MAX H1 + H2+ H3 MAXRear Vent Vertical Termination Venting with 3 elbows Rear Vent Vertical Termination Venting with 2 elbows+ H 2 MAX MIN Termination Cap Flue Damper Prior to installing the gas applianceCoaxial to Colinear Venting Clearances to CombustiblesMinimum Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Rear VentCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Top Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear Vent11 Proper Positioning and Securing of an Appliance Securing and Leveling the ApplianceAssemble Pipe Sections Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingFoot minimum in snow regions Install Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination 20 Venting through the wall Install Horizontal Termination Cap DVP and SLP PipeGas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsElectrical Information Wall Switch Installation for Fan Optional Junction Box InstallationFinishing NON-COMBUSTIBLE Board Included Facing MaterialAppliance Setup Install the Log Assembly Log Set Assembly LOGS-2014 Model QV32B-ALOG Air Shutter Setting Install the MeshInstall Trim and/or Surround Install HoodSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingReference Materials Appliance Dimension DiagramInches Millimeters Quadra-Fire QV32B-A, QV36B-A 2014-900 Rev. U 1/12 Vent Components DiagramsDVP vent components DVP-TRAPCOOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFLElbow Effective Height Length 222 mm 165 mm 165 mm9-1/4 235 mm 152 mm 168 mmElbow 251 mmSLP-WT-BK SLP-SNKD SLP-CCS-BKSL-2DVP SLP-DCF-BKLINK-DV30B DV-46DVA-GCL Vent Components Diagrams Coaxial to Colinear VentingDirect Vent Gas Fireplace Service PartsLog Set Assembly At DepotQV36B-A See valve assembly12.13 #12 Burner/Valve AssemblyPart number list on following 12.5 12.7 12.6 12.8 12.15 12.9Stocked Service Parts QV32B-A, QV36B-AQV36B-A Conversion Kits QV32B-A Conversion KitsContact Information