Top Vent - Vertical Termination
Venting with 3 elbows (NG)
V1 Minimum | H1 Maximum | V2 | V1 + V2 Minimum | ||
90 Elbow | 0 ft. | 305 mm | * | * | |
|
|
|
|
|
|
1/2 ft. | 152 mm | 2 ft. | 610 mm | * | * |
|
|
|
|
|
|
457 mm | 3 ft. | 914 mm | * | * | |
|
|
|
|
|
|
762 mm | 5 ft. | 1.5 m | * | * | |
|
|
|
|
|
|
1.1 m | 7 ft. | 2.1 m | * | * | |
|
|
|
|
|
|
1.4 m | 15 ft. | 4.6 m | * | * | |
|
|
|
|
|
|
H MAX. =15 ft. (4.6 m)
V1+ V2 + H1 MAX. = 40 ft. (12.2 m)
* No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m)
Top Vent - Vertical Termination
Venting with 3 elbows (Propane)
V1 Minimum | H1 Maximum | V2 | V1 + V2 Minimum | ||
90 Elbow | Not Allowed | * | * | ||
|
|
|
|
|
|
1/2 ft. | 152 mm | 1 ft. | 305 mm | * | * |
|
|
|
|
|
|
457 mm | 3 ft. | 914 mm | * | * | |
|
|
|
|
|
|
762 mm | 5 ft. | 1.5 m | * | * | |
|
|
|
|
|
|
1.1 m | 7 ft. | 2.1 m | * | * | |
1.4 m | 15 ft. | 4.6 m | * | * | |
|
|
|
|
|
|
H MAX. =15 ft. (4.6 m)
V1+ V2 + H1 MAX. = 40 ft. (12.2 m)
* No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m)
Note: Use SLP Series components only.
V2
Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.3).
H1
H2
V1
INSTALLED
HORIZONTALLY
Figure 7.10
29 |