Hearth and Home Technologies QV36B-A RF6M RF12M, BEK DVP-BEK2, Dvp-Trapfl, Cool-Add, Dvp-Hsm-B

Page 63

B. Vent Components Diagrams (continued)

 

 

 

 

31 in.

 

 

 

 

 

(787 mm)

 

13-1/4 in.

 

 

 

 

 

(367 mm)

 

 

24-5/8 in.

 

 

 

 

(625 mm)

 

 

24-5/8 in.

27-1/2 in.

 

 

 

 

(625 mm)

(127 mm)

 

 

 

13-1/4 in.

 

 

 

 

 

 

 

 

 

(367 mm)

RF6M

 

 

 

RF12M

 

Roof Flashing Multi-pak

 

 

 

 

Roof Flashing Multi-pak

 

 

 

 

 

13-3/4 in.

5 in.

 

 

11-7/8 in.

5 in.

(349 mm)

(127 mm)

 

 

(302 mm)

(127 mm)

13-3/4 in.

 

 

13-7/8 in.

 

 

 

 

(352 mm)

 

 

(349 mm)

 

 

 

 

 

 

 

 

 

BEK

 

 

 

DVP-BEK2

 

Trap Cap Brick Extension

 

 

DVP-HPC Cap Brick Extension

 

 

11-5/8 in.

 

 

 

 

 

(295 mm)

 

 

 

 

7-1/8 in.

 

12-1/8 in.

 

 

 

(308 mm)

 

 

(181 mm)

 

 

 

 

 

 

 

DVP-TRAPFL

 

5-3/4 in.

 

 

 

 

(146 mm)

COOL-ADD

 

Flashing

 

 

 

 

 

 

 

Cap Shield

 

 

 

 

 

26 in.

 

 

13-7/8 in.

9-1/2 in.

 

 

 

(352 mm)

(241 mm)

 

660 mm

 

 

 

 

 

 

 

14 in.

 

 

 

DVP-HSM-B

 

(356 mm)

 

 

 

Extended Heat Shield

 

 

 

 

 

Figure 16.4 DVP vent components

 

 

DRC-RADIUS

 

 

 

Cap Shield

 

 

 

 

 

 

Quadra-FireQV32B-A, QV36B-A2014-900 Rev. U • 1/12

63

Image 63
Contents Models What to do if you smell gasHOT Surfaces Homeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalLighting Instructions Standing Pilot Final inspection byWhat to do if YOU Smell GAS Frequently Asked Questions Issue SolutionsAfter Fireplace is Lit Maintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase ClearancesModels Mantel and Wall Projections Combustible MantelsCombustible Mantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesOpening Minimum Clearances for Termination Covered Alcove ApplicationsUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyClearance Use of Flex VentMinimum Maximum Top Vent Horizontal Termination Venting with 1 elbow PropaneV1 Minimum H1 + H2 Maximum Venting with 2 elbows NG Venting with 2 elbows PropaneMinimum + H 2 Maximum Top Vent Horizontal Termination Venting with 3 elbows NGExhaust restrictor Instructions Top Vent Vertical Termination No Elbow = 60 ft. Max .3 mV1 Minimum H1 Maximum V1 + V2 Minimum Top Vent Vertical Termination Venting with 2 elbows NGTop Vent Vertical Termination Venting with 2 elbows Propane Minimum Maximum + V 2 MinimumTop Vent Vertical Termination Venting with 3 elbows Propane Top Vent Vertical Termination Venting with 3 elbows NGV1 Min H1 Max V2 Min H2 Max V3 Min Top Vent Vertical Termination Four 90º ElbowsH1 + H2 MAX H1 MAX V1 MIN H2 MAXMIN MAX Rear Vent Horizontal Termination Venting with 3 elbowsRear Vent Vertical Termination Venting with 1 elbow H1 + H2 MAX H1 + H2+ H3 MAXRear Vent Vertical Termination Venting with 2 elbows Rear Vent Vertical Termination Venting with 3 elbows+ H 2 MAX MIN Termination Cap Flue Damper Prior to installing the gas applianceCoaxial to Colinear Venting Clearances to CombustiblesMinimum Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Rear VentCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Top Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear Vent11 Proper Positioning and Securing of an Appliance Securing and Leveling the ApplianceAssemble Pipe Sections Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarFoot minimum in snow regions Install Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination 20 Venting through the wall Install Horizontal Termination Cap DVP and SLP PipeGas Connection Gas InformationFuel Conversion Gas PressureWiring Requirements Optional Accessories RequirementsElectrical Information Wall Switch Installation for Fan Optional Junction Box InstallationFinishing NON-COMBUSTIBLE Board Included Facing MaterialAppliance Setup Install the Log Assembly Log Set Assembly LOGS-2014 Model QV32B-ALOG Air Shutter Setting Install the MeshInstall Trim and/or Surround Install HoodTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingAppliance Dimension Diagram Reference MaterialsInches Millimeters Quadra-Fire QV32B-A, QV36B-A 2014-900 Rev. U 1/12 Vent Components DiagramsDVP vent components DVP-TRAPCOOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFLElbow Effective Height Length 222 mm 165 mm 165 mm9-1/4 235 mm 152 mm 168 mmElbow 251 mmSLP-WT-BK SLP-SNKD SLP-CCS-BKSL-2DVP SLP-DCF-BKLINK-DV30B DV-46DVA-GCL Vent Components Diagrams Coaxial to Colinear VentingDirect Vent Gas Fireplace Service PartsLog Set Assembly At DepotQV36B-A See valve assembly12.13 #12 Burner/Valve AssemblyPart number list on following 12.5 12.7 12.6 12.8 12.15 12.9Stocked Service Parts QV32B-A, QV36B-AQV36B-A Conversion Kits QV32B-A Conversion KitsContact Information