Top Vent - Horizontal Termination | - (continued) |
|
| |||||
Three Elbows |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
V1 Minimum | H1 Maximum |
| H1 + H2 Maximum | V2 | V1 + V2 Minimum | |||
|
|
|
|
|
|
|
|
|
Elbow only | 1 ft. | 305 mm |
| 2 ft. | 610 mm | * | * | |
|
|
|
|
|
|
|
|
|
1/2 ft.** | 152 mm | 2 ft. | 610 mm |
| 4 ft. | 1.2 m | * | * |
457 mm | 3 ft. | 914 mm |
| 6 ft. | 1.8 m | * | * |
Note: Use SLP Series components only.
Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.3).
H2
V2
H1V1
WARNING **
Fire Risk.
•When using
a one foot minimum vertical vent section is required before installing first elbow.
•When using
Figure 7.6
Heat & Glo • | 27 |