Glowworm Lighting 40 manual Rear Flue Lengths

Page 12

4 Flue

NOTE:

The flue must be installed in accordance with the current issue of BS5440 Part 1.

Important. The flue must be installed with a fall of 35mm per metre (2o) towards the boiler, see diagram 4.1.

It is of no advantage to exceed this angle (2o) indeed sealing of the fan to flue elbow may become more difficult as the angle is increased.

The air and flue duct connect to the top of the boiler using an elbow which can be positioned to the side or rear.

The rear and side flue assemblies are designed for internal installation, but if necessary, due to insufficient clearances (boiler/flue terminal location) they can be installed from the outside.

For a wall thickness up to 300mm the flue can be fully installed from the inside.

For a wall thickness over 300mm the external cut hole will need to be made good from the outside.

The standard flue is able to provide the duct lengths as shown in diagram 4.2 for a rear flue and diagram 4.3 for a side flue.

If a longer flue duct is required, do not extend the ductings. A 1, 2 or 3metre long flue system and terminal can be supplied.

 

 

6860

 

'R'

 

REAR FLUE LENGTHS

 

 

R = Wall Thickness

 

STD Flue pack

75mm to 442mm

 

1m Flue pack

75mm to 953mm

 

2m Flue pack

75mm to 1953mm

 

3m Flue pack

75mm to 2933mm

 

 

Diagram 4.2

 

'S'

6861

 

 

Make sure flue slopes

 

 

 

 

 

2˚ down towards

 

 

 

 

 

 

 

 

 

 

the boiler

 

 

300mm

 

that is 35mm fall

 

 

 

 

 

 

 

 

 

 

 

per metre

 

 

 

 

 

 

of flue

 

 

 

 

 

 

 

 

 

 

 

 

 

length (2˚)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2˚

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REAR FLUE

SIDE VIEW

35mm

Make sure flue slopes 2˚ down

towards the boiler

that is 35mm fall per metre of flue length (2˚)

2˚

1metre

SIDE FLUE

FRONT VIEW

0158M

10.5mm

Diagram 4.1

SIDE FLUE LENGTHS

S = "External wall face" to "boiler casing"

STD Flue pack

80mm to 331mm

 

 

1m Flue pack

80mm to 841mm

 

 

2m Flue pack

80mm to 1841mm

 

 

3m Flue pack

80mm to 2821mm

 

 

Diagram 4.3

221834B

12

Image 12
Contents Guarantee Registration EnergysaverImportant Information CE MarkInstructions for Use Boilers Installed in a Compartment or Cupboard CleaningBoiler Clearances Protection Against FreezingOverheat Safety Cutoff To Turn the Boiler OnTo Turn the Boiler Off Condensation PlumingGeneral Sheet Metal Parts Statutory RequirementsBSI Certification Range RatingGas Supply Electrical SupplyCondensate Heating System ControlsWater System Expansion Vessel Flow Boiler MAXWater Sytem Pressure GaugeWater Makeup Filling a Sealed Water SystemBoiler Location Flue Rear Flue LengthsTerminal Position Terminal GuardUnpacking diagram PreparationRear and Side Flue Application Flue Hole Cutting Wall Mounting BracketWater and Condensate Connections Water ConnectionsCondensate Connection Flue Installation Flue Duct Wall Liner If a wall liner is used, fit self adhesive seal as followsGas Connection Electrical ConnectionTesting Electrical Pump and External Controls ConnectionInitial Lighting, Testing and Adjustment Testing GasCommissioning Preliminaries-All SystemsUser Information Heating SystemCondensate Check Operational ChecksHeat Exchanger Cleaning ServicingBurner InjectorSpark Electrode Condensate DrainFault Finding ElectricalCondensate Sensor Pump Overrun Operation Is there YES Faulty injector Replace Faulty PCB flame detectionDoes High neon light ? KEY Fault Finding Replacement of Parts Ignition Lead diagramCondensate Sensor diagram Printed Circuit Boards PCBs diagram Control PCB diagram 14.3 topInterconnecting PCB ICB diagram 14.3 bottom Control Thermostat diagram 14.4AHigh/Low Control diagram 14.4 Air Pressure Switch diagramMultifunctional Control diagram Heat Exchanger diagramHeat Exchanger Secondary diagram 14.8 FanHeat Exchanger Primary diagram Burner diagramInsulation Rear diagram Insulation Combustion Chamber Front Panel diagramInsulation Sides diagram Viewing Window Glass diagramSpare Parts Spare PartsDescription GC Part No 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.