Glowworm Lighting 40 manual Preparation, Unpacking diagram, Rear and Side Flue Application

Page 14

5 Preparation

5.1 Unpacking: diagram 5.1

Open top carton, remove top fitting, wall template, loose items fittings pack and boiler mounting bracket.

Remove carton wrap and spacing pieces

Lift off white outer case front. Remove protective packing piece.

Remove the cover of the inner case, see diagram 5.3.

For a side flue, extend the centre line horizontally (taking into account the required fall towards the boiler) left or right to the corner of the adjacent surface where the flue is required to exit to the outside. Alternatively, the increase in the centre height over a distance “X” is given by H = 0.35X. Mark the position of the centre of the flue as in diagram 5.4.

5.2 Rear and Side Flue Application

Having selected the location and flue application, with due regard to the terminal position:

Take the template and temporarily position it on the wall see diagram 5.4, making sure that the minimum clearances are maintained.

For a rear flue, mark the position of the flue as diagram 5.4.

INSTRUCTIONS

 

6289

 

 

 

TOP FITTING

WALL

 

 

TEMPLATE

 

 

 

 

TOP

 

 

CARTON

 

 

WRAP

 

BASE TRAY

Diagram 5.1

 

 

221834B

 

14

LOOSE ITEMS PACK

BOILER MOUNTING

 

No.10 x 3/

BRACKET

4

6288

SELF TAPPER

M5x10mm

 

INNER

FITTING

CONTROLS

FITTING

Note: Casing securing screws

 

supplied in loose items pack.

Diagram 5.2

Fit in order of numerical sequence.

 

 

 

 

SECURING

6290

SCREW(4)

 

INNER

CASE

Diagram 5.3

Image 14
Contents Guarantee Registration EnergysaverImportant Information CE MarkInstructions for Use Boiler Clearances Boilers Installed in a Compartment or CupboardCleaning Protection Against FreezingTo Turn the Boiler Off Overheat Safety CutoffTo Turn the Boiler On Condensation PlumingBSI Certification GeneralSheet Metal Parts Statutory Requirements Range RatingCondensate Gas SupplyElectrical Supply Heating System ControlsWater System Expansion Vessel Flow Boiler MAXWater Makeup Water SytemPressure Gauge Filling a Sealed Water SystemBoiler Location Flue Rear Flue LengthsTerminal Position Terminal GuardRear and Side Flue Application Unpacking diagramPreparation Flue Hole Cutting Wall Mounting BracketCondensate Connection Water and Condensate ConnectionsWater Connections Flue Installation Flue Duct Wall Liner If a wall liner is used, fit self adhesive seal as followsGas Connection Electrical ConnectionTesting Electrical Pump and External Controls ConnectionCommissioning Initial Lighting, Testing and AdjustmentTesting Gas Preliminaries-All SystemsCondensate Check User InformationHeating System Operational ChecksHeat Exchanger Cleaning ServicingSpark Electrode BurnerInjector Condensate DrainCondensate Sensor Fault FindingElectrical Pump Overrun Operation Is there YES Does High neon light ? Faulty injector ReplaceFaulty PCB flame detection KEY Fault Finding Condensate Sensor diagram Replacement of PartsIgnition Lead diagram Interconnecting PCB ICB diagram 14.3 bottom Printed Circuit Boards PCBs diagramControl PCB diagram 14.3 top Control Thermostat diagram 14.4AHigh/Low Control diagram 14.4 Air Pressure Switch diagramHeat Exchanger Secondary diagram Multifunctional Control diagramHeat Exchanger diagram 14.8 FanHeat Exchanger Primary diagram Burner diagramInsulation Sides diagram Insulation Rear diagramInsulation Combustion Chamber Front Panel diagram Viewing Window Glass diagramDescription GC Part No Spare PartsSpare Parts 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.