Glowworm Lighting 40 manual Important Information, CE Mark

Page 2

Important Information

TESTING AND CERTIFICATION

This boiler is tested and certificated for safety and performance. It is therefore important that no alteration is made to the boiler, without permission, in writing, from Hepworth Heating Ltd.

Any alteration not approved by Hepworth Heating Ltd., could invalidate the certification, boiler warranty and may also infringe the current issue of the Statutory Requirements, see Section 1.2.

CERAMIC FIBRE/INSULATION PADS, GLASSYARN.

These can cause irritation to skin, eyes and the respiratory tract. If you have a history of skin complaint you may be susceptible to irritation. High dust levels are usual only if the material is broken. Normal handling should not cause discomfort, but follow normal good hygiene and wash your hands before eating, drinking or going to the lavatory. If you do suffer irritation of the eyes or severe irritation to the skin seek medical attention.

CE MARK

This boiler meets the requirements of Statutory Instrument No. 3083 The boiler (Efficiency) Regulations, and therefore is deemed to meet the requirements of Directive 92/42/EEC on the efficiency requirements for new hot water boilers fired with liquid or gaseous fuels.

Type test for purposes of Regulation 5 certified by: Notified body 0086.

Product/productioncertifiedby: Notified body 0086.

The CE mark on this appliance shows compliance with:

1.Directive 90/396/EEC on the approximation of the laws of the Member States relating to appliances burning gaseous fuels.

2.Directive 73/23/EEC on the harmonization of the Laws of the Member States relating to the electrical equipment designed for use within certain voltage limits.

3.Directive 89/336/EEC on the approximation of the Laws of the Member States relating to electromagnetic compatibility.

INFORMATION FOR THE INSTALLER AND SERVICE ENGINEER.

Under Section 6 of The Health and Safety at Work Act 1974, we are required to provide information on substances hazardous to health.

THERMOSTATS

These contain very small amounts of xylene in the sealed phial and capillary. If broken, under normal circumstances the fluid does not cause a problem, but in case of skin contact, wash with cold water. If swallowed drink plenty of water and seek medical attention.

CUT OFF DEVICES

Cut off devices with copper phial/bulb only.

Bulb contains activated charcoal and very small amounts of chloroddifludromethane in the sealed phial and capillary. If broken under normal circumstances the fluid does not cause a problem. If there is irritation to the eyes or skin then seek medical attention.

FLUE SEALANT

This contains cyclohexylaminosilane.

It may cause irritation of skin of sensitive persons. Wash contact area with soap and water, if irritation occurs, seek medical advice.

It will cause irritation on contact with eyes. If so, wash eye with large amounts of fresh water for at least 15 minutes. If irritation occurs, seek medical advice.

If swallowed drink plenty of milk and seek medical advice.

CONTENTS

DESCRIPTION

SECTION

PAGE No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTRUCTIONS

 

Introduction

 

 

 

3

 

 

 

 

 

FOR USE

 

Lighting the Boiler

 

 

 

5

 

 

General Data

 

1

 

6

 

 

Water System

 

2

 

8

INSTALLATION

 

Boiler Location

 

3

 

11

 

Flue

 

4

 

12

INSTRUCTIONS

 

 

 

 

Preparation

 

5

 

14

 

 

Water and Condensate Connections

 

6

 

16

 

 

Flue Installation

 

7

 

17

 

 

Gas Connection

 

8

 

20

 

 

Electrical Connection

 

9

 

20

 

 

Commissioning

 

10

 

22

 

 

User Information

 

11

 

23

SERVICING

 

Servicing

 

12

 

24

 

Fault Finding

 

13

 

26

INSTRUCTIONS

 

Replacement Parts

 

14

 

33

 

Spare Parts

 

15

 

39

 

 

 

 

 

 

 

 

 

 

 

221834B

2

Image 2
Contents Guarantee Registration EnergysaverImportant Information CE MarkInstructions for Use Boiler Clearances Boilers Installed in a Compartment or CupboardCleaning Protection Against FreezingTo Turn the Boiler Off Overheat Safety CutoffTo Turn the Boiler On Condensation PlumingBSI Certification GeneralSheet Metal Parts Statutory Requirements Range RatingCondensate Gas SupplyElectrical Supply Heating System ControlsWater System Expansion Vessel Flow Boiler MAXWater Makeup Water SytemPressure Gauge Filling a Sealed Water SystemBoiler Location Flue Rear Flue LengthsTerminal Position Terminal GuardRear and Side Flue Application Unpacking diagramPreparation Flue Hole Cutting Wall Mounting BracketCondensate Connection Water and Condensate ConnectionsWater Connections Flue Installation Flue Duct Wall Liner If a wall liner is used, fit self adhesive seal as followsGas Connection Electrical ConnectionTesting Electrical Pump and External Controls ConnectionCommissioning Initial Lighting, Testing and AdjustmentTesting Gas Preliminaries-All SystemsCondensate Check User InformationHeating System Operational ChecksHeat Exchanger Cleaning ServicingSpark Electrode BurnerInjector Condensate DrainCondensate Sensor Fault FindingElectrical Pump Overrun Operation Is there YES Does High neon light ? Faulty injector ReplaceFaulty PCB flame detection KEY Fault Finding Condensate Sensor diagram Replacement of PartsIgnition Lead diagram Interconnecting PCB ICB diagram 14.3 bottom Printed Circuit Boards PCBs diagramControl PCB diagram 14.3 top Control Thermostat diagram 14.4AHigh/Low Control diagram 14.4 Air Pressure Switch diagramHeat Exchanger Secondary diagram Multifunctional Control diagramHeat Exchanger diagram 14.8 FanHeat Exchanger Primary diagram Burner diagramInsulation Sides diagram Insulation Rear diagramInsulation Combustion Chamber Front Panel diagram Viewing Window Glass diagramDescription GC Part No Spare PartsSpare Parts 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.