Glowworm Lighting 40 manual Flue Hole Cutting, Wall Mounting Bracket

Page 15

5 Preparation

5.3 Flue Hole Cutting

Having marked out the flue centre cut a hole for the flue see diagram 5.5 for minimum core drill size for various wall thicknesses.

This will allow for the 35mm per metre (2o) fall towards the boiler.

Note: If required, an optional Wall Liner Kit, part No.900862, is available, complete with fixing instructions.

5.4 Wall Mounting Bracket

Reposition the template, making sure of dimensional alignment with the flue centre lines

Mark the boiler securing screws and mounting plate position, see diagram 5.6.

Drill holes and plug, fit the securing screws allowing sufficient clearance to accept the keyhole fixing brackets and secure the boiler mounting bracket to the wall.

115 Minimum hole

0248M

 

125 up to 300mm wall

 

135 up to 680mm wall

 

 

56.5mm MIN

124mm

 

 

'H'=

 

 

0.035x

 

 

REAR FLUE

"x"

 

 

SIDE FLUE

 

 

 

 

Diagram 5.4

 

 

 

0249M

 

115

125

135

DIAMETER

DIAMETER

DIAMETER

 

See template for centre line positions

 

75

 

 

 

300

 

 

 

680

 

 

 

WALL THICKNESS

 

 

Diagram 5.5

 

 

 

15

221834B

Image 15
Contents Energysaver Guarantee RegistrationCE Mark Important InformationInstructions for Use Protection Against Freezing Boilers Installed in a Compartment or CupboardCleaning Boiler ClearancesCondensation Pluming Overheat Safety CutoffTo Turn the Boiler On To Turn the Boiler OffRange Rating GeneralSheet Metal Parts Statutory Requirements BSI CertificationHeating System Controls Gas SupplyElectrical Supply CondensateWater System Flow Boiler MAX Expansion VesselFilling a Sealed Water System Water SytemPressure Gauge Water MakeupBoiler Location Rear Flue Lengths FlueTerminal Guard Terminal PositionUnpacking diagram PreparationRear and Side Flue Application Wall Mounting Bracket Flue Hole CuttingWater and Condensate Connections Water ConnectionsCondensate Connection Flue Installation Flue Duct If a wall liner is used, fit self adhesive seal as follows Wall LinerElectrical Connection Gas ConnectionPump and External Controls Connection Testing ElectricalPreliminaries-All Systems Initial Lighting, Testing and AdjustmentTesting Gas CommissioningOperational Checks User InformationHeating System Condensate CheckServicing Heat Exchanger CleaningCondensate Drain BurnerInjector Spark ElectrodeFault Finding ElectricalCondensate Sensor Pump Overrun Operation Is there YES Faulty injector Replace Faulty PCB flame detectionDoes High neon light ? KEY Fault Finding Replacement of Parts Ignition Lead diagramCondensate Sensor diagram Control Thermostat diagram 14.4A Printed Circuit Boards PCBs diagramControl PCB diagram 14.3 top Interconnecting PCB ICB diagram 14.3 bottomAir Pressure Switch diagram High/Low Control diagram 14.414.8 Fan Multifunctional Control diagramHeat Exchanger diagram Heat Exchanger Secondary diagramBurner diagram Heat Exchanger Primary diagramViewing Window Glass diagram Insulation Rear diagramInsulation Combustion Chamber Front Panel diagram Insulation Sides diagramSpare Parts Spare PartsDescription GC Part No 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.