Glowworm Lighting 40 manual Fault Finding, Electrical, Condensate Sensor

Page 26

12 Servicing

INJECTOR

4059

MANIFOLD

 

 

SECURING

 

 

SCREW (3)

SECURING

SCREW (2)

Diagram 12.7

GASKET

4060

 

SECURING

SCREW (3)

CONDENSE

DRAIN TRAP

 

WASTE

CAP

OUTLET

Diagram 12.8

 

SECURING

 

SCREW (2)

4061

SILICONE

 

SLEEVING

IGNITION

AND

SENSING LEAD

SPARK

ELECTRODE

SPARK GAP 3mm to 4mm

Diagram 12.9

13 Fault Finding

13.1 Electrical

Important. On completion of the Service/Fault Finding task which has required the breaking and remaking of the electrical connections the earth continuity, polarity, short circuit and resistance to earth checks must be repeated using a suitable multimeter.

Refer to Fault Finding, Wiring, diagram 13.2 and Functional Flow diagram 13.3.

Note. Failure of an indicator light does not warrant the replacement of an otherwise satisfactory part.

13.2 Electrical Supply Failure

Failure of the electrical supply will cause the burner to go out.

Operation will normally resume on restoration of the electrical supply. If the boiler does not relight after an electrical supply failure the overheat device may need resetting.

To reset, press the reset button on the underside of the boiler, see diagram 13.4.

If the cutoff operates at any other time press the reset button and the burner should relight. If the fault persists refer to Fault Finding Chart.

There is a further cutoff mounted on the flue hood, see diagram 13.5 which also may need resetting.

13.3 Condensate Sensor

Refer to fault finding chart.

The boiler is fitted with a safety device to prevent the boiler from working if the condensate pipe gets blocked.

Remove the condensate drain cap, diagram 14.2.

If condensate is backing up to the sensor, the drain is blocked and it must be cleared before the boiler will work. Inspect external condensate pipe and clear away any debris or ice.

Release ice blockage by using warm cloths on the pipe.

221834B

26

Image 26
Contents Guarantee Registration EnergysaverImportant Information CE MarkInstructions for Use Boiler Clearances Boilers Installed in a Compartment or CupboardCleaning Protection Against FreezingTo Turn the Boiler Off Overheat Safety CutoffTo Turn the Boiler On Condensation PlumingBSI Certification GeneralSheet Metal Parts Statutory Requirements Range RatingCondensate Gas SupplyElectrical Supply Heating System ControlsWater System Expansion Vessel Flow Boiler MAXWater Makeup Water SytemPressure Gauge Filling a Sealed Water SystemBoiler Location Flue Rear Flue LengthsTerminal Position Terminal GuardRear and Side Flue Application Unpacking diagramPreparation Flue Hole Cutting Wall Mounting BracketCondensate Connection Water and Condensate ConnectionsWater Connections Flue Installation Flue Duct Wall Liner If a wall liner is used, fit self adhesive seal as followsGas Connection Electrical ConnectionTesting Electrical Pump and External Controls ConnectionCommissioning Initial Lighting, Testing and AdjustmentTesting Gas Preliminaries-All SystemsCondensate Check User InformationHeating System Operational ChecksHeat Exchanger Cleaning ServicingSpark Electrode BurnerInjector Condensate DrainCondensate Sensor Fault FindingElectrical Pump Overrun Operation Is there YES Does High neon light ? Faulty injector ReplaceFaulty PCB flame detection KEY Fault Finding Condensate Sensor diagram Replacement of PartsIgnition Lead diagram Interconnecting PCB ICB diagram 14.3 bottom Printed Circuit Boards PCBs diagramControl PCB diagram 14.3 top Control Thermostat diagram 14.4AHigh/Low Control diagram 14.4 Air Pressure Switch diagramHeat Exchanger Secondary diagram Multifunctional Control diagramHeat Exchanger diagram 14.8 FanHeat Exchanger Primary diagram Burner diagramInsulation Sides diagram Insulation Rear diagramInsulation Combustion Chamber Front Panel diagram Viewing Window Glass diagramDescription GC Part No Spare PartsSpare Parts 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.