14 Replacement of Parts

4078

CONTROL THERMOSTAT

SECURING SCREW (2)

 

 

RETAINING

 

 

PIN

 

 

OVERHEAT CUT

 

 

OFF PHIAL

 

ELECTRICAL

 

 

CONNECTION (5)

CONTROL

OVERHEAT

 

 

THERMOSTAT

CUT OFF

 

 

PHIAL

LOCKNUT

 

 

 

Diagram 14.4

CONTROLS

HIGH/LOW

CONTROL

4066

 

CONTROL

THERMOSTAT

FASCIA

KNOB

KNOB

 

 

 

SECURING

CONTROLS

SCREW (3)

FASCIA

 

Diagram 14.4A

 

4067S

ELECTRICAL

 

CONNECTIONS

 

RESET

FLUE HOOD

BUTTON

OVERHEAT

 

SECURING

THERMOSTAT

 

SCREW (2)

Diagram 14.5

14.5“High/Low” Control: diagram 14.4 and

Remove the fascia as described in Section 14.4. Remove the four screws securing the lights bracket. Remove the locknut to release the “High/Low” control. Disconnect the three in-line electrical connectors. When refitting refer to wiring diagram 13.2

14.6 Air Pressure Switch: diagram 14.7.

Remove the air pressure tubes and electrical connections.

Remove the two securing screws to release the air pressure switch.

When fitting the replacement make sure that all the air pressure tubes and electrical connections are made as shown.

35

221834B

Image 35
Contents Energysaver Guarantee RegistrationCE Mark Important InformationInstructions for Use Protection Against Freezing Boilers Installed in a Compartment or CupboardCleaning Boiler ClearancesCondensation Pluming Overheat Safety CutoffTo Turn the Boiler On To Turn the Boiler OffRange Rating GeneralSheet Metal Parts Statutory Requirements BSI CertificationHeating System Controls Gas SupplyElectrical Supply CondensateWater System Flow Boiler MAX Expansion VesselFilling a Sealed Water System Water SytemPressure Gauge Water MakeupBoiler Location Rear Flue Lengths FlueTerminal Guard Terminal PositionRear and Side Flue Application Unpacking diagramPreparation Wall Mounting Bracket Flue Hole CuttingCondensate Connection Water and Condensate ConnectionsWater Connections Flue Installation Flue Duct If a wall liner is used, fit self adhesive seal as follows Wall LinerElectrical Connection Gas ConnectionPump and External Controls Connection Testing ElectricalPreliminaries-All Systems Initial Lighting, Testing and AdjustmentTesting Gas CommissioningOperational Checks User InformationHeating System Condensate CheckServicing Heat Exchanger CleaningCondensate Drain BurnerInjector Spark ElectrodeCondensate Sensor Fault FindingElectrical Pump Overrun Operation Is there YES Does High neon light ? Faulty injector ReplaceFaulty PCB flame detection KEY Fault Finding Condensate Sensor diagram Replacement of PartsIgnition Lead diagram Control Thermostat diagram 14.4A Printed Circuit Boards PCBs diagramControl PCB diagram 14.3 top Interconnecting PCB ICB diagram 14.3 bottomAir Pressure Switch diagram High/Low Control diagram 14.414.8 Fan Multifunctional Control diagramHeat Exchanger diagram Heat Exchanger Secondary diagramBurner diagram Heat Exchanger Primary diagramViewing Window Glass diagram Insulation Rear diagramInsulation Combustion Chamber Front Panel diagram Insulation Sides diagramDescription GC Part No Spare PartsSpare Parts 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.