Instructions for Use

Boiler Clearances

If fixtures are positioned close to the boiler, space must be left as shown in diagram 3. Enough space must also be left in front of the boiler to allow for servicing.

Boilers Installed in a Compartment or Cupboard

If the boiler is installed in a cupboard or compartment do not obstruct any ventilation openings.

Do not use the cupboard or compartment for storage.

Regularly make sure that the air vent openings are clear of obstructions.

Cleaning

WARNING. This appliance contains metal parts (components) and care should be taken when handling and cleaning, with particular regard to edges.

Clean the casing occasionally by wiping it over with a damp soapy cloth or dry polishing duster.

Do not use an abrasive cleaner.

Protection Against Freezing

If the boiler is to be out of use for any long period of time during severe weather conditions we recommend that the whole of the system, including the boiler, be drained off to avoid the risk of freezing up. Make sure that, if fitted, the immersion heater in the cylinder is switched off.

If you have a sealed water system contact your installation/ servicing company as draining, refilling and pressurising must be carried out by a competent person.

Boiler Electrical Supply

WARNING. The boiler must be earthed.

The boiler must only be connected to a 240V~50Hz supply, protected by a 3A fuse.

All wiring must be in accordance with the current issue of BS7671.

The colours of three core flexible cable are:

Brown - live, Blue - neutral, green and yellow - earth.

As the markings on your plug may not correspond with these colours, continue as follows:

The wire coloured blue must be connected to the terminal marked “N” or “Black”.

The wire coloured brown must be connected to the terminal marked “R” or “Red”.

The wire coloured green and yellow must be connected to the

terminal marked “E”, “Green” or the earth symbol .

Electrical Supply Failure

Failure of the electrical supply will cause the burner to go out.

Should this happen, operation of the boiler will normally resume after the electrical supply is restored.

If the burner does not relight after an electrical supply failure the overheat device may need resetting, press the reset button on the underside of the boiler, see diagram 2.

150

*5

5

5 5

100

*INCREASE THIS DIMENSION TO 25mm FROM COMBUSTIBLE MATERIAL

*5

*5

500

PERMANENT SURFACE

CLEARANCE OPPOSITE TO FLUE EXIT MUST BE ADEQUATE FOR THE INTERNAL INSTALLATION

Diagram 3

221834B

4

Image 4
Contents Guarantee Registration EnergysaverImportant Information CE MarkInstructions for Use Boilers Installed in a Compartment or Cupboard CleaningBoiler Clearances Protection Against FreezingOverheat Safety Cutoff To Turn the Boiler OnTo Turn the Boiler Off Condensation PlumingGeneral Sheet Metal Parts Statutory RequirementsBSI Certification Range RatingGas Supply Electrical SupplyCondensate Heating System ControlsWater System Expansion Vessel Flow Boiler MAXWater Sytem Pressure GaugeWater Makeup Filling a Sealed Water SystemBoiler Location Flue Rear Flue LengthsTerminal Position Terminal GuardPreparation Unpacking diagramRear and Side Flue Application Flue Hole Cutting Wall Mounting BracketWater Connections Water and Condensate ConnectionsCondensate Connection Flue Installation Flue Duct Wall Liner If a wall liner is used, fit self adhesive seal as followsGas Connection Electrical ConnectionTesting Electrical Pump and External Controls ConnectionInitial Lighting, Testing and Adjustment Testing GasCommissioning Preliminaries-All SystemsUser Information Heating SystemCondensate Check Operational ChecksHeat Exchanger Cleaning ServicingBurner InjectorSpark Electrode Condensate DrainElectrical Fault FindingCondensate Sensor Pump Overrun Operation Is there YES Faulty PCB flame detection Faulty injector ReplaceDoes High neon light ? KEY Fault Finding Ignition Lead diagram Replacement of PartsCondensate Sensor diagram Printed Circuit Boards PCBs diagram Control PCB diagram 14.3 topInterconnecting PCB ICB diagram 14.3 bottom Control Thermostat diagram 14.4AHigh/Low Control diagram 14.4 Air Pressure Switch diagramMultifunctional Control diagram Heat Exchanger diagramHeat Exchanger Secondary diagram 14.8 FanHeat Exchanger Primary diagram Burner diagramInsulation Rear diagram Insulation Combustion Chamber Front Panel diagramInsulation Sides diagram Viewing Window Glass diagramSpare Parts Spare PartsDescription GC Part No 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.