Glowworm Lighting 40 manual Water and Condensate Connections, Water Connections

Page 16

 

 

 

5 Preparation

 

 

TEMPLATE

BOILER TOP

0170

 

AIR

4043S

 

FIXING POINTS

 

 

 

 

 

 

PRESSURE

CLEAR

 

7dia.

 

 

 

TUBES

 

 

 

RED TUBE

TUBES

 

 

 

NO.

 

 

 

 

3/16dia. PLUG

 

12x2in.

 

 

 

 

7dia.

 

 

 

 

 

 

3/16dia. PLUG

 

NO.

 

 

 

 

 

12x2in.

 

 

 

 

 

 

 

 

 

 

5mm

MOUNTING

 

ELECTRICAL

 

 

 

BRACKET

SECURING

 

 

 

FIXING

CONNECTIONS

 

 

 

SCREWS (3)

Diagram 5.7

 

 

POINT(S)

 

 

 

 

 

 

 

 

 

 

BOILER MOUNTING

5.5 Boiler Preparation

BRACKET

 

Lift the boiler into position above the boiler mounting bracket, lowering the boiler into position at the same time locating the key hole slots of the boiler on to the securing screws, when located secure the screws, see diagram 5.6.

Diagram 5.6

6 Water and Condensate Connections

6 Water Connections

Make the water connection to the heating system, see diagram 6.1.

The boiler has compression connections with nuts and olives supplied loose in the fittings pack, to accept 28mm outside diameter copper tubing to BS2871.

The 28mm connections can be reduced to 22mm for the Energysaver 40, provided the system resistance does not exceed the chosen pump duty.

The right hand connection is the flow from the boiler.

6.1 Condensate Connection

The condensate drain connection is at the bottom right of the boiler.

The drain ends in a spigot which is suitable for push fit 22mm (3/4in) plastic overflow pipe, for example, Hepworth Polypipe, Uponor, Osma, Orcaster. If using Marley, Terain or Hunter tubing, which is slightly larger, use the silicone sealant provided in the fittings pack to make a leak proof joint to the drain connection on the boiler.

The condensate discharge pipe should have a fall of 21/2o.

It is not necessary to provide air breaks, or traps in the discharge pipe since the boiler has an integral 50mm trap and siphon.

The boiler is fitted with a safety device to prevent the boiler from working if the condensate pipe gets blocked by either ice or debris.

It is, therefore, recommended that any external condensate drain pipe is insulated to prevent it freezing up.

Alternatively, a larger diameter pipe can be used and insulated.

The condensate drain pipe should be checked during any servicing and any debris found removed.

Refer to the British Gas publication “Guidance Notes for the Installation of Domestic Condensing Boiler” for advice on the disposal of boiler condensate.

 

UNION NUT

4037

 

 

 

28mm O.D.

 

OLIVE

 

COPPER

 

 

 

 

 

TUBING

 

 

 

RETURN

FLUE GAS

FLOW

SAMPLE

 

 

 

 

 

 

POINT

 

 

 

WATER CONNECTIONS

 

 

 

Diagram 6.1

221834B

16

Image 16
Contents Guarantee Registration EnergysaverImportant Information CE MarkInstructions for Use Boilers Installed in a Compartment or Cupboard CleaningBoiler Clearances Protection Against FreezingOverheat Safety Cutoff To Turn the Boiler OnTo Turn the Boiler Off Condensation PlumingGeneral Sheet Metal Parts Statutory RequirementsBSI Certification Range RatingGas Supply Electrical SupplyCondensate Heating System ControlsWater System Expansion Vessel Flow Boiler MAXWater Sytem Pressure GaugeWater Makeup Filling a Sealed Water SystemBoiler Location Flue Rear Flue LengthsTerminal Position Terminal GuardPreparation Unpacking diagramRear and Side Flue Application Flue Hole Cutting Wall Mounting BracketWater Connections Water and Condensate ConnectionsCondensate Connection Flue Installation Flue Duct Wall Liner If a wall liner is used, fit self adhesive seal as followsGas Connection Electrical ConnectionTesting Electrical Pump and External Controls ConnectionInitial Lighting, Testing and Adjustment Testing GasCommissioning Preliminaries-All SystemsUser Information Heating SystemCondensate Check Operational ChecksHeat Exchanger Cleaning ServicingBurner InjectorSpark Electrode Condensate DrainElectrical Fault FindingCondensate Sensor Pump Overrun Operation Is there YES Faulty PCB flame detection Faulty injector ReplaceDoes High neon light ? KEY Fault Finding Ignition Lead diagram Replacement of PartsCondensate Sensor diagram Printed Circuit Boards PCBs diagram Control PCB diagram 14.3 topInterconnecting PCB ICB diagram 14.3 bottom Control Thermostat diagram 14.4AHigh/Low Control diagram 14.4 Air Pressure Switch diagramMultifunctional Control diagram Heat Exchanger diagramHeat Exchanger Secondary diagram 14.8 FanHeat Exchanger Primary diagram Burner diagramInsulation Rear diagram Insulation Combustion Chamber Front Panel diagramInsulation Sides diagram Viewing Window Glass diagramSpare Parts Spare PartsDescription GC Part No 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.