6863

FLUE DUCT

"Q" plus 82mm

FLUE DUCT

"Q"

 

Diagram 7.2

 

 

 

 

3mm

4079

 

DRILL SIZE

 

 

AIR DUCT/TERMINAL

SEAL WITH

 

AND FLUE DUCT

 

ASSEMBLY

TAPE SUPPLIED

 

FLUE ELBOW

ASSEMBLY

AIR DUCT/

SEALANT TERMINAL AND

FLUE DUCT

ASSEMBLY

Diagram 7.3

6864

LONG FLUE

TERMINAL

STANDARD FLUE

TERMINAL

"N" minus 57mm

BOILER

CENTRE

LINE

"N"

Diagram 7.4

6885

"N" minus 42mm

BOILER

CENTRE

LINE

"N"

Diagram 7.5

221834B

18

Image 18
Contents Guarantee Registration EnergysaverImportant Information CE MarkInstructions for Use Boiler Clearances Boilers Installed in a Compartment or CupboardCleaning Protection Against FreezingTo Turn the Boiler Off Overheat Safety CutoffTo Turn the Boiler On Condensation PlumingBSI Certification GeneralSheet Metal Parts Statutory Requirements Range RatingCondensate Gas SupplyElectrical Supply Heating System ControlsWater System Expansion Vessel Flow Boiler MAXWater Makeup Water SytemPressure Gauge Filling a Sealed Water SystemBoiler Location Flue Rear Flue LengthsTerminal Position Terminal GuardUnpacking diagram PreparationRear and Side Flue Application Flue Hole Cutting Wall Mounting BracketWater and Condensate Connections Water ConnectionsCondensate Connection Flue Installation Flue Duct Wall Liner If a wall liner is used, fit self adhesive seal as followsGas Connection Electrical ConnectionTesting Electrical Pump and External Controls ConnectionCommissioning Initial Lighting, Testing and AdjustmentTesting Gas Preliminaries-All SystemsCondensate Check User InformationHeating System Operational ChecksHeat Exchanger Cleaning ServicingSpark Electrode BurnerInjector Condensate DrainFault Finding ElectricalCondensate Sensor Pump Overrun Operation Is there YES Faulty injector Replace Faulty PCB flame detectionDoes High neon light ? KEY Fault Finding Replacement of Parts Ignition Lead diagramCondensate Sensor diagram Interconnecting PCB ICB diagram 14.3 bottom Printed Circuit Boards PCBs diagramControl PCB diagram 14.3 top Control Thermostat diagram 14.4AHigh/Low Control diagram 14.4 Air Pressure Switch diagramHeat Exchanger Secondary diagram Multifunctional Control diagramHeat Exchanger diagram 14.8 FanHeat Exchanger Primary diagram Burner diagramInsulation Sides diagram Insulation Rear diagramInsulation Combustion Chamber Front Panel diagram Viewing Window Glass diagramSpare Parts Spare PartsDescription GC Part No 6291

40 specifications

Glowworm Lighting 40 is a popular choice for homeowners seeking energy-efficient heating solutions. This compact, wall-mounted boiler is designed with modern technologies that ensure optimal performance and reliability.

One of the standout features of the Glowworm 40 is its impressive efficiency rating. With an energy efficiency of up to 94%, it significantly reduces energy waste, resulting in lower utility bills and a reduced carbon footprint. This is particularly beneficial for environmentally conscious individuals looking to minimize their impact on the planet while maintaining comfort in their homes.

The Glowworm Lighting 40 is equipped with a robust heat exchanger made from high-grade aluminum, which not only enhances heat transfer efficiency but also contributes to the boiler's lightweight design. This feature makes installation easier, allowing for a more flexible placement within the home.

The boiler operates quietly, which is a crucial characteristic for residential areas where noise can be a concern. Its intelligent controls allow users to manage heating temperatures efficiently through programmable timers, ensuring that warmth is delivered only when needed. This not only helps with comfort but also ensures that energy is conserved.

Moreover, the Glowworm Lighting 40 comes with a built-in frost protection feature, which is essential for preventing damage during colder months. This technology ensures that the system remains operational even in extreme conditions, providing peace of mind to homeowners.

Another significant advantage of the Glowworm Lighting 40 is its compatibility with renewable energy technologies. The system can be easily integrated with solar thermal panels, enhancing the overall efficiency of the heating system and aligning with sustainable living principles.

Maintaining the Glowworm Lighting 40 is straightforward, thanks to its accessible design. Regular servicing is uncomplicated, encouraging adherence to maintenance schedules and prolonging the lifespan of the unit. This user-friendly aspect is a crucial consideration for many homeowners.

In summary, the Glowworm Lighting 40 combines efficiency, user-friendly technology, and innovative design. Its high efficiency rating, lightweight structure, quiet operation, and compatibility with renewable energy sources make it a leading contender in the boiler market for those looking for both practicality and environmental consciousness in their heating solutions. Whether upgrading an existing system or installing a new boiler, the Glowworm Lighting 40 delivers on performance and reliability.