Trane Building Automation System Tracker controller specifications, Specification Description

Page 17

®

Tracker controller specifications

Tracker controller specifications

Table 1 shows the specifications for the Tracker controller.

Table 1. Tracker Controller specifications

Specification

 

 

 

Description

 

 

Power

24 Vac nominal (19 Vac to 30 Vac),

 

50/60 Hz, 1 phase 40 VA minimum,

 

UL Class 2 transformer required

 

 

Operating environ-

From 32°F to 122°F (0°C to 50°C)

ment

10% to 90% relative humidity, non-condensing

 

 

Storage environment

From –40°F to 185°F (–40°C to 85°C)

 

5% to 95% relative humidity, non-condensing

 

 

Cabinet

NEMA 1 resin enclosure—plenum rated

 

 

Mounting

Flat wall surface with one of the following recessed

 

conduit boxes:

 

 

2 in. × 4 in.

(5.08 cm × 10.15 cm)

 

4 in. × 4 in.

(10.15 cm × 10.15 cm)

 

 

 

 

Dimensions

Height:

8.75 in.

(22.38 cm)

 

Width:

10.25 in.

(26.04 cm)

 

Depth:

2.75 in.

(6.99 cm)

 

 

 

 

Weight

2.5 lb

(1.13 kg)

 

 

 

 

Analog input

10 kat 77°F (25°C)

 

Thermistor

From –50°F to 200°F (–46°C to 93°C)

 

 

 

 

 

 

Binary inputs

User-supplied dry contacts only. Tracker-supplied

Utility pulse meter

voltage of 12 Vdc nominal (10 Vdc to 14 Vdc) at

12 mA nominal (10 mA to 14 mA).

Priority shutdown

 

 

 

 

 

 

Binary output

Tracker-supplied single-pole single-throw (SPST) dry

Alarm relay

contact rated at 24 Vac, 0.5 A maximum

 

 

 

 

 

 

Memory backup

At power loss, the system backs up memory and

 

stores all data for seven days. After seven days,

 

trends and alarms are not retained.

 

 

Approvals

See Appendix B, Declaration of Conformity.

 

 

 

 

 

BMTK-SVN01D-EN

9

Image 17
Contents Building Automation System Page BMTK-SVN01D-EN February Page BMTK-SVN01D-EN BMTK-SVN01D-EN Contents Appendix B Appendix aTracker controller OverviewOverview Overview Tracker controller components Controller componentsTermination module Termination module Main module Main moduleDisplay module Display moduleModel number definition Model numbersSpecification Description Tracker controller specificationsTracker Controller specifications Tracker model UCM type Maximum UCMs UCM maximum capacities for Tracker models 12Tracker controller models 12 and 24 UCM capacities 105 UCM maximum capacities for Tracker model WshpTracker controller model Wshp UCM capacities Verify the shipment Before installationInspect for shipping damage Store unused components until needed Avoid Equipment DamageTracker controller post-installation checklist After installationFCC compliance Select a location for the controller Verify location conformance to controller specificationsTermination module mounting Termination module mounting Minimum clearances Optimal touch screen viewing angles Mount the termination module Termination module conduit access and mounting holesSecuring the termination module to a conduit box Securing the termination module to a wallElectrical conduit installation Installing electrical conduitTermination module mounting Termination board wiring Termination board wiring Vac power Description Wire specifications Terminals Wire 24 Vac powerPower wiring specifications Input and output Description Wire specifications Terminals Wire optional inputs and outputsInput and output wire specifications Wire the priority shutdown device Wire the alarm relayWire the thermistor Wire the utility pulse meterWire specifications Wire the UCMsSupplier Cable type Number Details Catalog Pairs Trane-approved wire suppliersSpecification Value Specifications for Echelon Level 4 compliant cablesFigure Note UCM wiring configurationsWire the UCMs Tolerance Color sequence Termination resistor placement for Comm5 linksResistor color band table Daisy-chain termination resistor placement Tracker Requirements for repeaters on Comm5 communication links Wire supported UCMsConnecting communication link shield wiring to repeater Comm5 daisy-chain repeater connection Termination board wiring Main module mounting Main module mounting Display module mounting Display module mounting Display module engagement Display module mounting Verify PC workstation specifications PC workstation wiringCable and adapter specifications for direct connection Direct connection to PC workstationPC workstation wiring Tracker direct connection to a PC workstation Modem connection to PC workstation Tracker modem connection to a PC workstation Ethernet connection to PC workstation Connecting over an existing LANTracker Controller PC Workstation Connecting through a hubConnecting with one cable Troubleshooting components TroubleshootingService pin buttons and jumper LEDsTroubleshooting Tracker main logic board LEDs Alarm LEDLED name Color Description NumberService pin buttons/jumper Function Main logic board service pin buttons and jumperSymptom Action Symptom/action troubleshootingSymptom/action troubleshooting Present of the proper severity to actuate the alarm output Symptom/action troubleshooting Troubleshooting Calibrating the touch screen MaintenanceCleaning the touch screen Maintenance Required supplies checklist Installation checklistsOptional supplies checklist Required suppliesSpace Comfort Controllers 24 maximum Comm5 UCM identification and locationComm5 UCM identification and location Space Comfort Controllers Modules 4 maximum VariTrac central control panels 10 maximumPre-installation wiring notes Circuit Mandatory Test Actual value Wiring Termination module post-installation checklistTermination module post-installation checklist Temperature ºF Temperature ºC Sensor resistance Ohms x Thermistor sensor electrical characteristicsAppendix a Installation checklists Declaration of Conformity Product Number BMTK000AA0A110 When and where issuedElectromagnetic Emission Mark of Compliance European ContactNumerics IndexIndex Index Index Page Trane