Trane BMTK-SVN01D-EN, Building Automation System manual Overview

Page 10

®

Chapter 1 Overview

Figure 2. Example Tracker building automation system (models 12 and 24) on a network

VariTrac or VariTrane zone dampers

 

Voyager constant

 

Precedent rooftop

 

volume rooftop

Voyager rooftop

with ReliaTel controls

Interconnecting wiring

 

TCI-V

 

 

 

 

(Comm5 link): single, twisted

 

VariTrac central

 

pair, shielded wire for two-

Tracer

control panel

Tracer

way communication.

 

 

LCI-V

 

LCI-R

Utility pulse meter input

Outdoor air

temperature sensor input

Priority shutdown contact input

Universal inputs

Binary outputs

Tracer MP503

I/O module

Analog inputs

Binary inputs

Tracer ZN517

Binary outputs

 

 

 

 

 

Generic rooftop

unitary controller

 

 

 

 

 

 

Alarm relay output

Tracker controller

Direct, dial-in (modem), or Ethernet connection

2

BMTK-SVN01D-EN

Image 10
Contents Building Automation System Page BMTK-SVN01D-EN February Page BMTK-SVN01D-EN BMTK-SVN01D-EN Contents Appendix a Appendix BOverview Tracker controllerOverview Overview Controller components Tracker controller componentsTermination module Termination moduleMain module Main moduleDisplay module Display moduleModel numbers Model number definitionTracker Controller specifications Tracker controller specificationsSpecification Description Tracker controller models 12 and 24 UCM capacities UCM maximum capacities for Tracker models 12Tracker model UCM type Maximum UCMs Tracker controller model Wshp UCM capacities UCM maximum capacities for Tracker model Wshp105 Inspect for shipping damage Before installationVerify the shipment Store unused components until needed Avoid Equipment DamageAfter installation Tracker controller post-installation checklistFCC compliance Termination module mounting Verify location conformance to controller specificationsSelect a location for the controller Termination module mounting Minimum clearances Optimal touch screen viewing angles Termination module conduit access and mounting holes Mount the termination moduleSecuring the termination module to a wall Securing the termination module to a conduit boxInstalling electrical conduit Electrical conduit installationTermination module mounting Termination board wiring Termination board wiring Power wiring specifications Wire 24 Vac powerVac power Description Wire specifications Terminals Input and output wire specifications Wire optional inputs and outputsInput and output Description Wire specifications Terminals Wire the alarm relay Wire the priority shutdown deviceWire the utility pulse meter Wire the thermistorWire the UCMs Wire specificationsTrane-approved wire suppliers Supplier Cable type Number Details Catalog PairsSpecifications for Echelon Level 4 compliant cables Specification ValueUCM wiring configurations Figure NoteWire the UCMs Resistor color band table Termination resistor placement for Comm5 linksTolerance Color sequence Daisy-chain termination resistor placement Tracker Wire supported UCMs Requirements for repeaters on Comm5 communication linksConnecting communication link shield wiring to repeater Comm5 daisy-chain repeater connection Termination board wiring Main module mounting Main module mounting Display module mounting Display module mounting Display module engagement Display module mounting Cable and adapter specifications for direct connection PC workstation wiringVerify PC workstation specifications Direct connection to PC workstationPC workstation wiring Tracker direct connection to a PC workstation Modem connection to PC workstation Tracker modem connection to a PC workstation Connecting over an existing LAN Ethernet connection to PC workstationConnecting through a hub Tracker Controller PC WorkstationConnecting with one cable Service pin buttons and jumper TroubleshootingTroubleshooting components LEDsTroubleshooting LED name Alarm LEDTracker main logic board LEDs Color Description NumberMain logic board service pin buttons and jumper Service pin buttons/jumper FunctionSymptom/action troubleshooting Symptom/action troubleshootingSymptom Action Present of the proper severity to actuate the alarm output Symptom/action troubleshooting Troubleshooting Cleaning the touch screen MaintenanceCalibrating the touch screen Maintenance Optional supplies checklist Installation checklistsRequired supplies checklist Required suppliesComm5 UCM identification and location Comm5 UCM identification and locationSpace Comfort Controllers 24 maximum Space Comfort Controllers VariTrac central control panels 10 maximum Modules 4 maximumPre-installation wiring notes Termination module post-installation checklist Termination module post-installation checklistCircuit Mandatory Test Actual value Wiring Thermistor sensor electrical characteristics Temperature ºF Temperature ºC Sensor resistance Ohms xAppendix a Installation checklists Declaration of Conformity Electromagnetic Emission When and where issuedProduct Number BMTK000AA0A110 Mark of Compliance European ContactIndex NumericsIndex Index Index Page Trane