3.Connecting The Cable Between Indoor Unit and Outdoor Unit
1)Connect the cable to the Indoor unit.
•Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No. are the same as those of the indoor unit.)
The earth wire should be longer than the common wires.
CAUTION
•When installing, refer to the circuit diagram on the Control Box of Indoor Unit.
•When installing, refer to the wiring diagram on the Control Cover Inside Outdoor Unit.
CAUTION
•The above circuit diagram is subject to change with- out notice.
•Be sure to connect wires according to the wiring dia- gram.
•Connect the wires firmly, so that not to be pulled out easily.
•Connect the wires according to color codes by refer- ring the wiring diagram.
CAUTION
If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.
The power cord connected to the "A" unit should be complied with the following specifications
(Type "B" approved by HAR or SAA).
|
|
|
|
|
| (mm2) | |
NORMAL |
|
| Grade |
|
| ||
CROSS |
|
|
|
|
|
| |
5k~9K | 12k~14k | 18k | 24k~28k | 30k, 32k | 36k, 38k | ||
0.75 | 1.0 | 1.5 | 2.5 | 2.5 | 5.5 | ||
AREA | |||||||
Unit(A) | Indoor | Indoor | Indoor | Indoor | Outdoor | Outdoor |
Cable Type(B)
The power connecting cable connected to the indoor and outdoor unit should be complied with the following specifications
(Type "B" approved by HAR or SAA).
Main power source
Air |
| Circuit Breaker |
Conditioner |
| Use a circuit |
|
| breaker or time |
|
| |
|
| delay fuse. |
|
|
|
| (mm2) | |
NORMAL |
| Grade |
| ||
CROSS |
|
|
|
| |
5k~9k | 12k~14k | 18k | 24k~28k | ||
0.75 | 1.0 | 1.5 | 2.5 | ||
AREA |
Cable Type(B)
(mm2)
NORMAL CROSS | Grade | ||
|
| ||
30k, 32k | 36k, 38k | ||
0.75 | 0.75 | ||
| |||
|
|
| |
Cable Type(B) | |||
|
|
|
NORMAL