LG Electronics LS-Q076ABL, LS-Q096BBG, LS-Q096ACG, LS-Q096BEL LS-C082QMA0 LS-C082QNAO LS-C096QGL0

Page 80

Parts List(Outdoor)

LOCATION

DESCRIPTION

 

 

PART No.

 

REMARKS

No.

 

 

 

 

 

LS-C082QMA0

LS-C082QNAO

LS-C096QGL0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

430410

BASE ASSY,WELD[OUTDOOR]

3041AR2415E

3041AR2415E

3041AR2415K

R

 

 

 

 

 

 

 

435301

GRILLE,DISCHARGE

-

-

-

R

 

 

 

 

 

 

 

435511

COVER ASSEMBLY,CONTROL(OUTDOOR)

4994AR3492B

4994AR3492B

4994AR3492B

R

 

 

 

 

 

 

 

437210

GRILLE ASSEMBLY,FRONT(OUTDOOR)

3531AR2512R

3531AR2512R

3531AR2512R

R

 

 

 

 

 

 

 

437212

PANEL ASSEMBLY,REAR(OUTDOOR)

3530AR0058B

3530AR0058B

3530AR0058B

R

 

 

 

 

 

 

 

546810

MOTOR ASSEMBLY,OUTDOOR

4681A20068K

4681A20068K

4681A20004F

R

 

 

 

 

 

 

 

550140

ISOLATOR,COMP

4H00982E

4H00982E

4H00982E

R

 

 

 

 

 

 

 

552102

TUBE,CAPILLARY BEND

5424AR3582C

5424AR3582C

5424AR3582H

R

 

 

 

 

 

 

 

552102-1

TUBE,CAPILLARY BEND

-

-

-

R

 

 

 

 

 

 

 

552102-2

TUBE,CAPILLARY BEND

-

-

-

R

 

 

 

 

 

 

 

552111

TUBE ASSY,CAPILLARY

5211A30337A

5211A30337A

5211A30275D

R

 

 

 

 

 

 

 

552116

TUBE ASSY,REVERSING

-

-

-

R

 

 

 

 

 

 

 

552201

VALVE,CHECK

-

-

-

R

 

 

 

 

 

 

 

552202

VALVE,REVERSING

-

-

-

R

 

 

 

 

 

 

 

552203-1

VALVE,SERVICE

2H02479F

2H02479F

2H02479F

R

 

 

 

 

 

 

 

552203-2

VALVE,SERVICE

2A00393U

2A00393U

2A00393U

R

 

 

 

 

 

 

 

554031

CONDENSER ASSEMBLY,BENT

5403AR2870H

5403AR2870H

5403AR2870M

R

 

 

 

 

 

 

 

554160

COMPRESSOR

5416A20013J

5416A20013J

5416A20013L

R

 

 

 

 

 

 

 

559010

FAN ASSEMBLY,PROPELLER

5900AR1266A

5900AR1266A

5900AR1266A

R

 

 

 

 

 

 

 

561410

COIL ASSY,REVERSING VALVE

-

-

-

R

 

 

 

 

 

 

 

567502

O.L.P

6750A30001D

6750A30001D

6750A30001C

R

 

 

 

 

 

 

 

649950

CONTROL BOX ASSEMBLY,OUTDOOR

4995AR2566N

4995AR2566N

4995AR2566F

R

 

 

 

 

 

 

 

W0CZZ

CAPACITOR,DRAWING

6120AR2194G

6120AR2194G

2H01451P

R

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request. (GCSC WEBSITE http://biz.LGservice.com)

-80-

Image 80
Contents Room Air Conditioner Contents Details of LG Model Name2002 Code Type Code of Model MeaningDetails of LG Model Name2003~ MeaningFunctions Indoor UnitRemote Control Airflow Direction Control Air Circulation Room, Temperature CheckingPLASMAOptional Setting the Time or Timer Timer Selection Unit Product ReferencesModel Name 1Ø, 220V, 60Hz Dimensions All ModelsOutdoor Unit 9k Heat Pump Refrigeration Cycle Diagram Cooling Only ModelsWiring Diagram LS-Q096ABL, LS-Q096AEL LS-H096QNA0, LS-H096QNA0Operation Details Cooling Mode OperationHealthy Dehumidification Mode Heating Mode Operation Defrost ControlFuzzy Operation for Cooling Fuzzy Operation C/O ModelFuzzy Operation H/P Model On-Timer Operation Airflow Speed SelectionFuzzy Operation for Dehumidification Fuzzy Operation for HeatingOff-Timer Operation Off-Timer ↔ On-Timer OperationSleep Timer Operation Chaos Swing ModeJet Cool Mode Operation C/O Model Jet Cool Mode Operation H/P ModelAir Cleaner Operation Forced OperationBuzzer Sounding Operation Remote Control Operation ModeProtection of the evaporator pipe from frosting Display Function Self-diagnosis FunctionHeating Model Cooling ModelPiping length and elevation InstallationSelection of the best location How to fix installation plate Drill a hole in the wallFlaring work For right rear piping Indoor unit installationConnection of piping Indoor Wrap the insulation material around the connecting portion Tighten the flare nut with a wrenchInsert the connecting cable into the indoor unit Tape the drain hose and the connecting cableTighten the flare nut by hand Connection of the pipes-OutdoorAlign the center of the pipings and sufficiently Connecting The Cable Between Indoor Unit and Outdoor Unit Connect the cable to the Indoor unitConnect the cable to the outdoor unit Checking the drainage Form the pipingTo remove the front panel from the indoor unit To check the drainagePrepare remote control Pump Down ProcedureSettlement of outdoor unit Evaluation of the performanceName and Function-Remote Control OperationON/OFF Timer Buttons Disassembly of the parts Indoor unit To remove the Grille from the ChassisWhen repair, do not damage the Caution label To remove the Control BoxTo remove the Discharge Grille To remove the EvaporatorTo remove the Motor Cover To remove the Cross-Flow FanWay, 3-way Valve Way Valve Liquid SidePurge the air from the system ProcedureCheck for gas leakage Air purging of the charge hose Set the 2-way valve to the closed positionRe-air purging Balance refrigerant of the 2-way, 3-way valves Gas leakageEvacuation All amount of refrigerant leakedPurge the air from the charge hose After EvacuationConnect the charge hose to the charging cylinder Cycle Troubleshooting Guide Trouble analysisElectronic Parts Troubleshooting Guide Product is not operate with the remote control Compressor/Outdoor Fan are unable to drive When indoor Fan does not operate When Vertical Louver does not operate When Heating does not operate Way RelayPage Electronic Control Device Main P.W.B Assembly DC Part TOP View Bottom View TOP View 6871A20227 TOP View 6871A20194 TOP View6871A30009 TOP View 6871A20390 TOP View 6871A20391 TOP ViewSchematic Diagram LED Type HVB Typeplasma Heat Pump Model LED Type Heat Pump Model HVB Type Exploded View and Replacement Parts List Parts ListIndoor LS-Q076ABL LS-Q076BBG LS-Q076BELLS-Q096ABL LS-Q096BBG CABLE, Flat CABLE, Falt Cover ASSEMBLY,MOTOR LS-Q082AAL LS-C082QMA0 LS-C082QNA0 LS-C096QGL0 LS-C096QLA0 LS-C096QNA0 LS-H096QGL1 W0CZZ Parts ListOutdoor 552202 567502 561410 554160 447910 550140 430410 552203-2 TUBE,CAPILLARY Bend Compressor Base ASSEMBLY,OUTDOOR Tube ASSY,CAPILLARY LS-C082QMA0 LS-C082QNAO LS-C096QGL0 3041AR2415K April