LG Electronics LS-Q076BEL, LS-Q096BBG, LS-Q096ACG Operation, Name and Function-Remote Control

Page 34
Used to set the desired horizontal airflow direction.
TON (NOT ON ALL MODELS)
HORIZONTAL AIRFLOW DIRECTION CONTROL BUT-
Used to adjust the time.
TIME SETTING BUTTONS
PLASMA(OPTION)
13 Used to start or stop the plasma-purification function.
14 RESET BUTTON
Used prior to resetting time or after replacing batteries.
15
TIMER SET/CANCEL BUTTONS
9 Used to set the timer when the desired time is obtained and to cancel the Timer operation.
SLEEP MODE AUTO BUTTON
10 Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
11 Used to circulate the room air without cooling or heat- ing.
12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature.
ON/OFF TIMER BUTTONS
7 Used to set the time of starting and stopping operation.
8
INDOOR FAN SPEED SELECTOR
4 Used to select fan speed in four steps low, medium, high and CHAOS.
JET COOL
5 Used to start or stop the speed cooling. (Speed cooling operates super high fan speed in cooling mode.)
6 CHAOS SWING BUTTON
Used to stop or start louver movement and set the desired up/down airflow direction.

Operation

Name and Function-Remote Control

The remote control transmits the signals to the system.

1

Remote Control

2

Signal transmitter

3

5

6

4

1

 

3

ON

OFF

7

10

8

11

SET

CANCEL

9

12

2

PLASMA

13

15

14

Flip-up door (opened)

START/STOP BUTTON

Operation starts when this button is pressed and stops when the button is pressed again.

OPERATION MODE SELECTION BUTTON

Used to select the operation mode.

ROOM TEMPERATURE SETTING BUTTONS

Used to select the room temperature.

Operation Mode

Cooling Operation

Auto Operation

Healthy Dehumidification Operation

Heating Operation

• Cooling Model( ), Heat Pump Model( )

-34-

Image 34
Contents Room Air Conditioner Contents Details of LG Model Name2002 Code Type Code of Model MeaningDetails of LG Model Name2003~ MeaningFunctions Indoor UnitRemote Control PLASMAOptional Setting the Time or Timer Timer Selection Room, Temperature CheckingAirflow Direction Control Air Circulation Model Name Product ReferencesUnit 1Ø, 220V, 60Hz Dimensions All ModelsOutdoor Unit 9k Heat Pump Refrigeration Cycle Diagram Cooling Only ModelsWiring Diagram LS-Q096ABL, LS-Q096AEL LS-H096QNA0, LS-H096QNA0Healthy Dehumidification Mode Cooling Mode OperationOperation Details Heating Mode Operation Defrost ControlFuzzy Operation H/P Model Fuzzy Operation C/O ModelFuzzy Operation for Cooling Fuzzy Operation for Dehumidification On-Timer OperationAirflow Speed Selection Fuzzy Operation for HeatingSleep Timer Operation Off-Timer OperationOff-Timer ↔ On-Timer Operation Chaos Swing ModeAir Cleaner Operation Jet Cool Mode Operation C/O ModelJet Cool Mode Operation H/P Model Forced OperationProtection of the evaporator pipe from frosting Remote Control Operation ModeBuzzer Sounding Operation Heating Model Display FunctionSelf-diagnosis Function Cooling ModelSelection of the best location InstallationPiping length and elevation How to fix installation plate Drill a hole in the wallFlaring work Connection of piping Indoor Indoor unit installationFor right rear piping Wrap the insulation material around the connecting portion Tighten the flare nut with a wrenchInsert the connecting cable into the indoor unit Tape the drain hose and the connecting cableAlign the center of the pipings and sufficiently Connection of the pipes-OutdoorTighten the flare nut by hand Connecting The Cable Between Indoor Unit and Outdoor Unit Connect the cable to the Indoor unitConnect the cable to the outdoor unit To remove the front panel from the indoor unit Checking the drainageForm the piping To check the drainageSettlement of outdoor unit Prepare remote controlPump Down Procedure Evaluation of the performanceName and Function-Remote Control OperationON/OFF Timer Buttons Disassembly of the parts Indoor unit To remove the Grille from the ChassisTo remove the Discharge Grille When repair, do not damage the Caution labelTo remove the Control Box To remove the EvaporatorTo remove the Motor Cover To remove the Cross-Flow FanWay, 3-way Valve Way Valve Liquid SideCheck for gas leakage ProcedurePurge the air from the system Air purging of the charge hose Set the 2-way valve to the closed positionRe-air purging Balance refrigerant of the 2-way, 3-way valves Gas leakageEvacuation All amount of refrigerant leakedConnect the charge hose to the charging cylinder After EvacuationPurge the air from the charge hose Cycle Troubleshooting Guide Trouble analysisElectronic Parts Troubleshooting Guide Product is not operate with the remote control Compressor/Outdoor Fan are unable to drive When indoor Fan does not operate When Vertical Louver does not operate When Heating does not operate Way RelayPage Electronic Control Device Main P.W.B Assembly DC Part TOP View Bottom View TOP View 6871A30009 TOP View 6871A20194 TOP View6871A20227 TOP View 6871A20390 TOP View 6871A20391 TOP ViewSchematic Diagram LED Type HVB Typeplasma Heat Pump Model LED Type Heat Pump Model HVB Type Exploded View and Replacement Parts List Parts ListIndoor LS-Q076ABL LS-Q076BBG LS-Q076BELLS-Q096ABL LS-Q096BBG CABLE, Flat CABLE, Falt Cover ASSEMBLY,MOTOR LS-Q082AAL LS-C082QMA0 LS-C082QNA0 LS-C096QGL0 LS-C096QLA0 LS-C096QNA0 LS-H096QGL1 W0CZZ Parts ListOutdoor 552202 567502 561410 554160 447910 550140 430410 552203-2 TUBE,CAPILLARY Bend Compressor Base ASSEMBLY,OUTDOOR Tube ASSY,CAPILLARY LS-C082QMA0 LS-C082QNAO LS-C096QGL0 3041AR2415K April