LG Electronics LS-Q096BEL, LS-Q096BBG, LS-Q096ACG, LS-Q076ABL, LS-Q076BBG, LS-Q096ADL 3041AR2415K

Page 81

Parts List(Outdoor)

LOCATION

DESCRIPTION

 

 

PART No.

 

REMARKS

No.

 

 

 

 

 

LS-C096QLA0

LS-C096QNA0

LS-H096QGL1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

430410

BASE ASSY,WELD[OUTDOOR]

3041AR2415K

3041AR2415K

3041A20016A

R

 

 

 

 

 

 

 

435301

GRILLE,DISCHARGE

-

-

3530A10059G

R

 

 

 

 

 

 

 

435511

COVER ASSEMBLY,CONTROL(OUTDOOR)

4994AR3492B

4994AR3492B

3551A30023Q

R

 

 

 

 

 

 

 

437210

GRILLE ASSEMBLY,FRONT(OUTDOOR)

3531AR2512R

3531AR2512R

3720A10171A

R

 

 

 

 

 

 

 

437212

PANEL ASSEMBLY,REAR(OUTDOOR)

3530AR0058B

3530AR0058B

3720A10172A

R

 

 

 

 

 

 

 

546810

MOTOR ASSEMBLY,OUTDOOR

4681A20004F

4681A20004F

4681A20121A

R

 

 

 

 

 

 

 

550140

ISOLATOR,COMP

4H00982E

4H00982E

4H00982E

R

 

 

 

 

 

 

 

552102

TUBE,CAPILLARY BEND

5424AR3582H

5424AR3582H

5210A20595F

R

 

 

 

 

 

 

 

552102-1

TUBE,CAPILLARY BEND

-

-

-

R

 

 

 

 

 

 

 

552102-2

TUBE,CAPILLARY BEND

-

-

-

R

 

 

 

 

 

 

 

552111

TUBE ASSY,CAPILLARY

5211A30275D

5211A30275D

5211A20133Z

R

 

 

 

 

 

 

 

552116

TUBE ASSY,REVERSING

-

-

5211A21027B

R

 

 

 

 

 

 

 

552201

VALVE,CHECK

-

-

-

R

 

 

 

 

 

 

 

552202

VALVE,REVERSING

-

-

5220AR3084E

R

 

 

 

 

 

 

 

552203-1

VALVE,SERVICE

2H02479F

2H02479F

2H02479P

R

 

 

 

 

 

 

 

552203-2

VALVE,SERVICE

2A00393U

2A00393U

5220A20040A

R

 

 

 

 

 

 

 

554031

CONDENSER ASSEMBLY,BENT

5403AR2870M

5403AR2870M

5403A20059F

R

 

 

 

 

 

 

 

554160

COMPRESSOR

5416A20013L

5416A20013L

5416A20013L

R

 

 

 

 

 

 

 

559010

FAN ASSEMBLY,PROPELLER

5900AR1266A

5900AR1266A

5900AR1266A

R

 

 

 

 

 

 

 

561410

COIL ASSY,REVERSING VALVE

-

-

3A02028Y

R

 

 

 

 

 

 

 

567502

O.L.P

6750A30001C

6750A30001C

6750A30001C

R

 

 

 

 

 

 

 

649950

CONTROL BOX ASSEMBLY,OUTDOOR

4995AR2566F

4995AR2566F

4995A10032J

R

 

 

 

 

 

 

 

W0CZZ

CAPACITOR,DRAWING

2H01451P

2H01451P

2H01451P

R

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request. (GCSC WEBSITE http://biz.LGservice.com)

-81-

Image 81
Contents Room Air Conditioner Contents Code Type Code of Model Meaning Details of LG Model Name2002Meaning Details of LG Model Name2003~Indoor Unit FunctionsRemote Control Room, Temperature Checking PLASMAOptional Setting the Time or Timer Timer SelectionAirflow Direction Control Air Circulation Product References Model NameUnit 1Ø, 220V, 60Hz All Models DimensionsOutdoor Unit 9k Heat Pump Cooling Only Models Refrigeration Cycle DiagramLS-Q096ABL, LS-Q096AEL LS-H096QNA0, LS-H096QNA0 Wiring DiagramCooling Mode Operation Healthy Dehumidification ModeOperation Details Defrost Control Heating Mode OperationFuzzy Operation C/O Model Fuzzy Operation H/P ModelFuzzy Operation for Cooling Airflow Speed Selection On-Timer OperationFuzzy Operation for Dehumidification Fuzzy Operation for HeatingOff-Timer ↔ On-Timer Operation Off-Timer OperationSleep Timer Operation Chaos Swing ModeJet Cool Mode Operation H/P Model Jet Cool Mode Operation C/O ModelAir Cleaner Operation Forced OperationRemote Control Operation Mode Protection of the evaporator pipe from frostingBuzzer Sounding Operation Self-diagnosis Function Display FunctionHeating Model Cooling ModelInstallation Selection of the best locationPiping length and elevation Drill a hole in the wall How to fix installation plateFlaring work Indoor unit installation Connection of piping IndoorFor right rear piping Tighten the flare nut with a wrench Wrap the insulation material around the connecting portionTape the drain hose and the connecting cable Insert the connecting cable into the indoor unitConnection of the pipes-Outdoor Align the center of the pipings and sufficientlyTighten the flare nut by hand Connect the cable to the Indoor unit Connecting The Cable Between Indoor Unit and Outdoor UnitConnect the cable to the outdoor unit Form the piping Checking the drainageTo remove the front panel from the indoor unit To check the drainagePump Down Procedure Prepare remote controlSettlement of outdoor unit Evaluation of the performanceOperation Name and Function-Remote ControlON/OFF Timer Buttons To remove the Grille from the Chassis Disassembly of the parts Indoor unitTo remove the Control Box When repair, do not damage the Caution labelTo remove the Discharge Grille To remove the EvaporatorTo remove the Cross-Flow Fan To remove the Motor CoverWay Valve Liquid Side Way, 3-way ValveProcedure Check for gas leakagePurge the air from the system Set the 2-way valve to the closed position Air purging of the charge hoseRe-air purging Gas leakage Balance refrigerant of the 2-way, 3-way valvesAll amount of refrigerant leaked EvacuationAfter Evacuation Connect the charge hose to the charging cylinderPurge the air from the charge hose Trouble analysis Cycle Troubleshooting GuideElectronic Parts Troubleshooting Guide Product is not operate with the remote control Compressor/Outdoor Fan are unable to drive When indoor Fan does not operate When Vertical Louver does not operate Way Relay When Heating does not operatePage Electronic Control Device Main P.W.B Assembly DC Part TOP View Bottom View TOP View 6871A20194 TOP View 6871A30009 TOP View6871A20227 TOP View 6871A20391 TOP View 6871A20390 TOP ViewSchematic Diagram LED Type HVB Typeplasma Heat Pump Model LED Type Heat Pump Model HVB Type Exploded View and Replacement Parts List LS-Q076ABL LS-Q076BBG LS-Q076BEL Parts ListIndoorLS-Q096ABL LS-Q096BBG CABLE, Flat CABLE, Falt Cover ASSEMBLY,MOTOR LS-Q082AAL LS-C082QMA0 LS-C082QNA0 LS-C096QGL0 LS-C096QLA0 LS-C096QNA0 LS-H096QGL1 W0CZZ Parts ListOutdoor 552202 567502 561410 554160 447910 550140 430410 552203-2 TUBE,CAPILLARY Bend Compressor Base ASSEMBLY,OUTDOOR Tube ASSY,CAPILLARY LS-C082QMA0 LS-C082QNAO LS-C096QGL0 3041AR2415K April