2-way, 3-way Valve

2-way Valve (Liquid Side)

3-way Valve (Gas Side)

 

 

Valve cap

 

Hexagonal wrench (4mm)

 

Open position

Flare nut

Flare nut

Closed position

Open position

 

 

Pin

Closed position

 

 

 

 

 

To

To

 

 

piping

piping

Service

Service

connection

connection

port cap

port

 

 

To outdoor unit

To outdoor unit

 

 

Works

Shaft position

Shaft position

Service port

 

 

 

 

 

 

Shipping

Closed

Closed

Closed

 

(with valve cap)

(with valve cap)

(with cap)

 

 

 

 

 

 

 

 

Air purging

Open

Closed

Open

1.

(Installation)

(counter-clockwise)

(clockwise)

(push-pin or with

 

 

 

 

vacumm pump)

 

 

 

 

 

 

Operation

Open

Open

Closed

 

(with valve cap)

(with valve cap)

(with cap)

 

 

 

 

 

 

 

 

Pumping down

Closed

Open

Open

2.

(clockwise)

(counter-clockwise)

(connected manifold

(Transfering)

 

 

 

gauge)

 

 

 

 

 

 

 

 

 

 

Evacuation

Open

Open

Open

3.

 

 

(with charging

(Servicing)

 

 

 

 

 

 

cylinder)

 

 

 

 

 

 

Gas charging

Open

Open

Open

4.

(Servicing)

 

 

(with charging

 

 

 

 

cylinder)

 

 

 

 

 

 

Pressure check

 

 

Open

5.

(Servicing)

Open

Open

(with charging cylinder)

 

 

 

 

 

6.

Gas releasing

Open

Open

Open

(Servicing)

(with charging cylinder)

 

 

 

 

 

 

 

 

 

-39-

Image 39
Contents Room Air Conditioner Contents Code Type Code of Model Meaning Details of LG Model Name2002Meaning Details of LG Model Name2003~Indoor Unit FunctionsRemote Control Room, Temperature Checking PLASMAOptional Setting the Time or Timer Timer SelectionAirflow Direction Control Air Circulation Product References Model NameUnit 1Ø, 220V, 60Hz All Models DimensionsOutdoor Unit 9k Heat Pump Cooling Only Models Refrigeration Cycle DiagramLS-Q096ABL, LS-Q096AEL LS-H096QNA0, LS-H096QNA0 Wiring DiagramCooling Mode Operation Healthy Dehumidification ModeOperation Details Defrost Control Heating Mode OperationFuzzy Operation C/O Model Fuzzy Operation H/P ModelFuzzy Operation for Cooling Fuzzy Operation for Heating On-Timer OperationAirflow Speed Selection Fuzzy Operation for DehumidificationChaos Swing Mode Off-Timer OperationOff-Timer ↔ On-Timer Operation Sleep Timer OperationForced Operation Jet Cool Mode Operation C/O ModelJet Cool Mode Operation H/P Model Air Cleaner OperationRemote Control Operation Mode Protection of the evaporator pipe from frostingBuzzer Sounding Operation Cooling Model Display FunctionSelf-diagnosis Function Heating ModelInstallation Selection of the best locationPiping length and elevation Drill a hole in the wall How to fix installation plateFlaring work Indoor unit installation Connection of piping IndoorFor right rear piping Tighten the flare nut with a wrench Wrap the insulation material around the connecting portionTape the drain hose and the connecting cable Insert the connecting cable into the indoor unitConnection of the pipes-Outdoor Align the center of the pipings and sufficientlyTighten the flare nut by hand Connect the cable to the Indoor unit Connecting The Cable Between Indoor Unit and Outdoor UnitConnect the cable to the outdoor unit To check the drainage Checking the drainageForm the piping To remove the front panel from the indoor unitEvaluation of the performance Prepare remote controlPump Down Procedure Settlement of outdoor unitOperation Name and Function-Remote ControlON/OFF Timer Buttons To remove the Grille from the Chassis Disassembly of the parts Indoor unitTo remove the Evaporator When repair, do not damage the Caution labelTo remove the Control Box To remove the Discharge GrilleTo remove the Cross-Flow Fan To remove the Motor CoverWay Valve Liquid Side Way, 3-way ValveProcedure Check for gas leakagePurge the air from the system Set the 2-way valve to the closed position Air purging of the charge hoseRe-air purging Gas leakage Balance refrigerant of the 2-way, 3-way valvesAll amount of refrigerant leaked EvacuationAfter Evacuation Connect the charge hose to the charging cylinderPurge the air from the charge hose Trouble analysis Cycle Troubleshooting GuideElectronic Parts Troubleshooting Guide Product is not operate with the remote control Compressor/Outdoor Fan are unable to drive When indoor Fan does not operate When Vertical Louver does not operate Way Relay When Heating does not operatePage Electronic Control Device Main P.W.B Assembly DC Part TOP View Bottom View TOP View 6871A20194 TOP View 6871A30009 TOP View6871A20227 TOP View 6871A20391 TOP View 6871A20390 TOP ViewSchematic Diagram LED Type HVB Typeplasma Heat Pump Model LED Type Heat Pump Model HVB Type Exploded View and Replacement Parts List LS-Q076ABL LS-Q076BBG LS-Q076BEL Parts ListIndoorLS-Q096ABL LS-Q096BBG CABLE, Flat CABLE, Falt Cover ASSEMBLY,MOTOR LS-Q082AAL LS-C082QMA0 LS-C082QNA0 LS-C096QGL0 LS-C096QLA0 LS-C096QNA0 LS-H096QGL1 W0CZZ Parts ListOutdoor 552202 567502 561410 554160 447910 550140 430410 552203-2 TUBE,CAPILLARY Bend Compressor Base ASSEMBLY,OUTDOOR Tube ASSY,CAPILLARY LS-C082QMA0 LS-C082QNAO LS-C096QGL0 3041AR2415K April