LG Electronics LS-Q096ABG Off-Timer Operation, Off-Timer ↔ On-Timer Operation, Chaos Swing Mode

Page 19

Off-Timer Operation

When the set time is reached after the time is input by the remote control, the appliance stops operating.

The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached.

If the appliance is on pause at the time set by the timer, the pause continues.

Off-Timer On-Timer Operation

When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation is carried out according to the set time.

Sleep Timer Operation

When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote control while in appli- ance operation, the operation of the appliance stops.

While the appliance is on pause, the sleep timer mode cannot be input.

While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature increases by 1°C. After another 30 min elapse, it increases by 1°C again.

When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to the low.

When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to the medium.

Chaos Swing Mode

By the Chaos Swing key input, the upper/lower vane automatically operates with the Chaos Swing or they are fixed to the desired direction.

While in Chaos Swing mode, the angles of cooling and heating cycle operations are different.

< Cooling Mode >

CLOSED

7°

OPEN

Chaos Natural Wind Mode

< Heating Mode >

CLOSED

7°

OPEN

When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the air- flow mode is operated for 2~15 sec. randomly by the Chaos Simulation.

-19-

Image 19
Contents Room Air Conditioner Contents Code Type Code of Model Meaning Details of LG Model Name2002Meaning Details of LG Model Name2003~Indoor Unit FunctionsRemote Control PLASMAOptional Setting the Time or Timer Timer Selection Room, Temperature CheckingAirflow Direction Control Air Circulation Model Name Product ReferencesUnit 1Ø, 220V, 60Hz All Models DimensionsOutdoor Unit 9k Heat Pump Cooling Only Models Refrigeration Cycle DiagramLS-Q096ABL, LS-Q096AEL LS-H096QNA0, LS-H096QNA0 Wiring DiagramHealthy Dehumidification Mode Cooling Mode OperationOperation Details Defrost Control Heating Mode OperationFuzzy Operation H/P Model Fuzzy Operation C/O ModelFuzzy Operation for Cooling Fuzzy Operation for Heating On-Timer OperationAirflow Speed Selection Fuzzy Operation for DehumidificationChaos Swing Mode Off-Timer OperationOff-Timer ↔ On-Timer Operation Sleep Timer OperationForced Operation Jet Cool Mode Operation C/O ModelJet Cool Mode Operation H/P Model Air Cleaner OperationProtection of the evaporator pipe from frosting Remote Control Operation ModeBuzzer Sounding Operation Cooling Model Display FunctionSelf-diagnosis Function Heating ModelSelection of the best location InstallationPiping length and elevation Drill a hole in the wall How to fix installation plateFlaring work Connection of piping Indoor Indoor unit installationFor right rear piping Tighten the flare nut with a wrench Wrap the insulation material around the connecting portionTape the drain hose and the connecting cable Insert the connecting cable into the indoor unitAlign the center of the pipings and sufficiently Connection of the pipes-OutdoorTighten the flare nut by hand Connect the cable to the Indoor unit Connecting The Cable Between Indoor Unit and Outdoor UnitConnect the cable to the outdoor unit To check the drainage Checking the drainageForm the piping To remove the front panel from the indoor unitEvaluation of the performance Prepare remote controlPump Down Procedure Settlement of outdoor unitOperation Name and Function-Remote ControlON/OFF Timer Buttons To remove the Grille from the Chassis Disassembly of the parts Indoor unitTo remove the Evaporator When repair, do not damage the Caution labelTo remove the Control Box To remove the Discharge GrilleTo remove the Cross-Flow Fan To remove the Motor CoverWay Valve Liquid Side Way, 3-way ValveCheck for gas leakage ProcedurePurge the air from the system Set the 2-way valve to the closed position Air purging of the charge hoseRe-air purging Gas leakage Balance refrigerant of the 2-way, 3-way valvesAll amount of refrigerant leaked EvacuationConnect the charge hose to the charging cylinder After EvacuationPurge the air from the charge hose Trouble analysis Cycle Troubleshooting GuideElectronic Parts Troubleshooting Guide Product is not operate with the remote control Compressor/Outdoor Fan are unable to drive When indoor Fan does not operate When Vertical Louver does not operate Way Relay When Heating does not operatePage Electronic Control Device Main P.W.B Assembly DC Part TOP View Bottom View TOP View 6871A30009 TOP View 6871A20194 TOP View6871A20227 TOP View 6871A20391 TOP View 6871A20390 TOP ViewSchematic Diagram LED Type HVB Typeplasma Heat Pump Model LED Type Heat Pump Model HVB Type Exploded View and Replacement Parts List LS-Q076ABL LS-Q076BBG LS-Q076BEL Parts ListIndoorLS-Q096ABL LS-Q096BBG CABLE, Flat CABLE, Falt Cover ASSEMBLY,MOTOR LS-Q082AAL LS-C082QMA0 LS-C082QNA0 LS-C096QGL0 LS-C096QLA0 LS-C096QNA0 LS-H096QGL1 W0CZZ Parts ListOutdoor 552202 567502 561410 554160 447910 550140 430410 552203-2 TUBE,CAPILLARY Bend Compressor Base ASSEMBLY,OUTDOOR Tube ASSY,CAPILLARY LS-C082QMA0 LS-C082QNAO LS-C096QGL0 3041AR2415K April