LG Electronics LS-Q096ADG, LS-Q096BBG, LS-Q096ACG, LS-Q076ABL, LS-Q096BEL TUBE,CAPILLARY Bend

Page 76

Parts List(Outdoor)

LOCATION

DESCRIPTION

 

 

PART No.

 

 

REMARKS

No.

 

 

 

 

 

 

LS-Q096ACG

LS-Q096BAG

LS-Q096ACL

LS-Q082BAG

LS-Q096ABM

LS-H096QNA0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

430410

BASE ASSEMBLY, WELD[OUTDOOR]

3041AR2415K

3041AR2415K

3041AR2415K

3041AR2415E

3041A20008K

3041A20016A

R

 

 

 

 

 

 

 

 

 

435301

GRILLE, DISCHARGE

3530A20006B

3530A20006B

3530A20006B

3530A20006B

3530A20006B

3530A10059D

R

 

 

 

 

 

 

 

 

 

435511

COVER ASSEMBLY, CONTROL(OUTDOOR)

4994AR3492B

4994AR3492B

4994AR3492B

4994AR3492B

3551A30023E

3551A30023Q

R

 

 

 

 

 

 

 

 

 

437210

PANEL ASSEMBLY, FRONT(OUTDOOR)

3531AR2512R

3531AR2512R

3531AR2512R

3531AR2512R

3721A20027A

3721A20060B

R

 

 

 

 

 

 

 

 

 

437212

PANEL ASSEMBLY, REAR(OUTDOOR)

3530AR0058B

3530AR0058B

3530AR0058B

3530AR0058B

3721A20026B

3721A20059A

R

 

 

 

 

 

 

 

 

 

447910

BARRIER ASSEMBLY, OUTDOOR

-

-

-

-

-

4971A30002B

R

 

 

 

 

 

 

 

 

 

546810

MOTOR ASSEMBLY, OUTDOOR

4681A20004F

4681A20004F

4681A20004F

4681A20068A

4681A20004J

4791A20011A

R

 

 

 

 

 

 

 

 

 

550140

ISOLATOR, COMP

4H00982E

4H00982E

4H00982E

4H00982E

4H00982E

4681A20004F

R

 

 

 

 

 

 

 

 

 

552102-1

TUBE, CAPILLARY BEND

5424AR3582H

5424AR3582H

5424AR3582H

5424AR3582C

5210A21341A

4H00982E

R

5424AR7208M

 

 

 

 

 

 

 

 

 

552102-2

TUBE,CAPILLARY BEND

-

-

-

-

-

5210A20595F

R

 

 

 

 

 

 

 

 

 

552111

TUBE ASSEMBLY, CAPILLARY

5211A30275D

5211A30275D

5211A30275D

5211A30337A

5211A20117E

5211A20133Z

R

 

 

 

 

 

 

 

 

 

552116

TUBE ASSEMBLY, REVERSING

-

-

-

-

5211A20116C

5211A21027B

R

 

 

 

 

 

 

 

 

 

552201

VALVE, CHECK

-

-

-

-

3H01552F

-

R

 

 

 

 

 

 

 

 

 

552202

VALVE, REVERSING

-

-

-

-

5220AR3084A

5220AR3084E

R

 

 

 

 

 

 

 

 

 

552203-1

VALVE, SERVICE

2H02479F

2H02479F

2H02479F

2H02479F

2H02479H

2H02479N

R

 

 

 

 

 

 

 

 

 

552203-2

VALVE, SERVICE

2A00393U

2A00393U

2A00393U

2A00393U

2A00393U

2A00393Z

R

 

 

 

 

 

 

 

 

 

554031

CONDENSER ASSEMBLY, BENT

5403AR2870F

5403AR2870M

5403AR2870F

5403AR2870P

5403A20028H

5403A20059B

R

 

 

 

 

 

 

 

 

 

554160

COMPRESSOR SET

5416A20013L

5416A20013L

5416A20013L

5416A20013J

5416A20013C

5417A20012H

R

 

 

 

 

 

 

 

 

 

559010

FAN ASSEMBLY, PROPELLER

5900AR1266A

5900AR1266A

5900AR1266A

5900AR1266A

5901A10004A

5900AR1266A

R

 

 

 

 

 

 

 

 

 

561410

COIL ASSEMBLY, REVERSING VALVE

-

-

-

-

3A02028Y

3A02028Y

R

 

 

 

 

 

 

 

 

 

567502

O.L.P

6750A30001C

6750A30001C

6750A30001C

6750A30001C

6750A30001C

6750A30001C

R

 

 

 

 

 

 

 

 

 

649950

CONTROL BOX ASSEMBLY, OUTDOOR

4995AR2566B

4995AR2566B

4995AR2566B

4995AR2566E

4995A20083F

4995A10032J

R

 

 

 

 

 

 

 

 

 

W0CZZ

CAPACITOR, DRAWING

2H01451P

2H01451P

2H01451P

2H01451P

2H01451P

2H01451P

R

 

 

 

 

 

 

 

 

 

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request. (GCSC WEBSITE http://biz.LGservice.com)

-76-

Image 76
Contents Room Air Conditioner Contents Details of LG Model Name2002 Code Type Code of Model MeaningDetails of LG Model Name2003~ MeaningFunctions Indoor UnitRemote Control PLASMAOptional Setting the Time or Timer Timer Selection Room, Temperature CheckingAirflow Direction Control Air Circulation Model Name Product ReferencesUnit 1Ø, 220V, 60Hz Dimensions All ModelsOutdoor Unit 9k Heat Pump Refrigeration Cycle Diagram Cooling Only ModelsWiring Diagram LS-Q096ABL, LS-Q096AEL LS-H096QNA0, LS-H096QNA0Healthy Dehumidification Mode Cooling Mode OperationOperation Details Heating Mode Operation Defrost ControlFuzzy Operation H/P Model Fuzzy Operation C/O ModelFuzzy Operation for Cooling On-Timer Operation Airflow Speed SelectionFuzzy Operation for Dehumidification Fuzzy Operation for HeatingOff-Timer Operation Off-Timer ↔ On-Timer OperationSleep Timer Operation Chaos Swing ModeJet Cool Mode Operation C/O Model Jet Cool Mode Operation H/P ModelAir Cleaner Operation Forced OperationProtection of the evaporator pipe from frosting Remote Control Operation ModeBuzzer Sounding Operation Display Function Self-diagnosis FunctionHeating Model Cooling ModelSelection of the best location InstallationPiping length and elevation How to fix installation plate Drill a hole in the wallFlaring work Connection of piping Indoor Indoor unit installationFor right rear piping Wrap the insulation material around the connecting portion Tighten the flare nut with a wrenchInsert the connecting cable into the indoor unit Tape the drain hose and the connecting cableAlign the center of the pipings and sufficiently Connection of the pipes-OutdoorTighten the flare nut by hand Connecting The Cable Between Indoor Unit and Outdoor Unit Connect the cable to the Indoor unitConnect the cable to the outdoor unit Checking the drainage Form the pipingTo remove the front panel from the indoor unit To check the drainagePrepare remote control Pump Down ProcedureSettlement of outdoor unit Evaluation of the performanceName and Function-Remote Control OperationON/OFF Timer Buttons Disassembly of the parts Indoor unit To remove the Grille from the ChassisWhen repair, do not damage the Caution label To remove the Control BoxTo remove the Discharge Grille To remove the EvaporatorTo remove the Motor Cover To remove the Cross-Flow FanWay, 3-way Valve Way Valve Liquid SideCheck for gas leakage ProcedurePurge the air from the system Air purging of the charge hose Set the 2-way valve to the closed positionRe-air purging Balance refrigerant of the 2-way, 3-way valves Gas leakageEvacuation All amount of refrigerant leakedConnect the charge hose to the charging cylinder After EvacuationPurge the air from the charge hose Cycle Troubleshooting Guide Trouble analysisElectronic Parts Troubleshooting Guide Product is not operate with the remote control Compressor/Outdoor Fan are unable to drive When indoor Fan does not operate When Vertical Louver does not operate When Heating does not operate Way RelayPage Electronic Control Device Main P.W.B Assembly DC Part TOP View Bottom View TOP View 6871A30009 TOP View 6871A20194 TOP View6871A20227 TOP View 6871A20390 TOP View 6871A20391 TOP ViewSchematic Diagram LED Type HVB Typeplasma Heat Pump Model LED Type Heat Pump Model HVB Type Exploded View and Replacement Parts List Parts ListIndoor LS-Q076ABL LS-Q076BBG LS-Q076BELLS-Q096ABL LS-Q096BBG CABLE, Flat CABLE, Falt Cover ASSEMBLY,MOTOR LS-Q082AAL LS-C082QMA0 LS-C082QNA0 LS-C096QGL0 LS-C096QLA0 LS-C096QNA0 LS-H096QGL1 W0CZZ Parts ListOutdoor 552202 567502 561410 554160 447910 550140 430410 552203-2 TUBE,CAPILLARY Bend Compressor Base ASSEMBLY,OUTDOOR Tube ASSY,CAPILLARY LS-C082QMA0 LS-C082QNAO LS-C096QGL0 3041AR2415K April