One pound of gas pressure is equal to 27.7 inches water column pressure

Inches of Water Column X .036091 = PSI

Inches of Water Column X .073483 = Inches of Mercury (Hg.)

Centimeters = Inches X 2.54

MM (millimeters) =Inches X 25.4

Meters = Inches X .0254

Doubling the diameter of a pipe will increase its flow capacity (approximately) 5.3 times.

Construction: Tank is constructed of steel.

The inside of the tank is constructed of a glass lining bonded to the steel. This prevents water to metal contact and rusting of the tank.

An anode rod will be installed within the tank. The hex-head plug end of the anode is visible on the top of the water heater. This metal rod offers secondary protection of the tank against corrosion where the application of glass is not possible (threaded tank openings). These areas will have small areas of water to metal contact.

All water heaters will contain at least one thermostat (to operate the heater) and one high limit (to prevent water temperatures approaching the “steam” level).

40

Image 40 Contents
Models GPX, GS6, GSX Series 200/201 06/09 316876-000Page Service Handbook Tools Required for servicing gas modelsFire or Explosion Harzard Insufficient HOT Water No HOT WaterWater Leakage Problem Possible Cause Test / Corrective Action Table of Contents Basic Installation & Operation See Labels and Installation InstructionsWater Supply- Cold Use & Care Guide for clearances To Fixtures HotTemperature-Pressure Anode RodHot Water Cold WaterNormal Operation Thermal Cut Off Switch TCO The water heater Basic Installation & Operation Combustion Air Requirements Carbon Monoxide WarningReference Vent Connectors PER FT Draining and Filling the Water Heater Draining the Water Heater Filling the Water HeaterChecking the GAS Supply Pressure Checking for Sufficient Combustion AIR or Venting IssuesThen Draft Test Testing the Thermocouple and GAS Control VALVE/THERMOSTAT Thermal Switch ModelsRemoving the Burner from the Manifold/ Burner Assembly Removing the Manifold/Burner AssemblyReplacing the Thermocouple Replacing the Thermocouple and GAS Control VALVE/THERMOSTAT Replacing the Manifold/Burner AssemblyExplosion Hazard Removing the Gas Valve Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Water Time to Produce 2nd & 3rd GAS Water Heater Sizing Guide Leakage CheckpointsTechnical Bulletins 35-36Water Hammer GeneralEffects FIXMineral BUILD-UP SymptomsCause If tank is new with no lime build-up to any degree Aluminum HydroxideIf tank is new with lime build-up to any degree Causes CondensationDiagnosis Discolored Water TreatmentSmelly Water Procedure Chlorination ProcedureStep Test Not Enough HOT Water GASResults Thermal Expansion Outlet Inlet Cold Water Inlet Valve SHUT-OFF Valve Leaking Temperature and Pressure Relief Valve Insulation Blankets General Information Formulas and ConversionsMM millimeters =Inches X Page Page