Operating Instructions
BLOWER SPEED:
The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). Pressing the fan’s three (3) position rocker switch on the unit’s control panel will change the speed of the fan; it is Low/Off/High (refer to Figure 4). The fan can not be controlled with the handset.
NORMAL SOUNDS DURING OPERATION:
| Table 2: Normal Sounds. |
|
|
Component | Sound & Reason |
Sonnet & Surrounds | Creaking when heating up or cooling down. |
Burner | Light pop or poof when turned off; this is more common with LP units. |
|
|
Temperature Sensor | Clicking when it senses to turn the blower on or off. |
|
|
Blower / Fan | Air movement that increase and decreases with the speed of the blower. |
| The blower is pushing the heat from the fireplace into the room. |
|
|
Gas Control Valve | Dull click when turning on or off, this is the valve opening and closing. |
ADJUSTING VENTURI AIR SETTINGS:
There is one venturi adjustment. Use this venturi adjustment lever, shown in Figure 7, to achieve a proper and efficient flame. Pull the rod forward for more air or push it in for less air. Adjust lever until the flame pattern is similar to Figure 77.
Figure 7: Adjusting the venturi air setting.
10