Enviro C-11089, Sonnet owner manual To Test Valve Pressures, Opening Inlet Pressure Tap on

Page 27

Initial Installation

QUALIFIED INSTALLERS ONLY

 

 

 

 

 

Figure 55: Opening Inlet Pressure Tap on

Figure 54: Labeled Gas Valve.

 

Valve.

TO TEST VALVE PRESSURES:

The pressure taps are located on the front side of the valve (see Figure 54 & 55).

1.Remove the door (refer to MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL), log set and ember material, brick panels, burner tray, and the valve cover to access the valve (refer to MAINTENANCE AND

SERVICE - REMOVING VALVE COVER).

2.Turn set screw one (1) turn counter-clockwise to loosen.

3.Place 5/16 in (8 mm) I.D. hose over the pressure taps.

4.Check pressures using a manometer.

5.When finished, release pressure, remove hose and tighten set screw.

6.Re-install the valve cover, burner tray, brick panels (refer to SECONDARY INSTALLATION - INSTALLING

THE BRICK PANELS), log set and ember material (refer to SECONDARY INSTALLATION - LOG SET AND EMBER

INSTALLATION) and the glass door.

Always check for gas leaks with a soap and water solution after completing the required pressure test.

Table 6: Orifice and Pressure Information.

Main Burner

Natural Gas

Propane Gas

 

 

 

Orifice:

#42 DMS

#54 DMS

 

 

 

Manifold Press:

4.0 W.C. (0.99 KPa)

10.0 W.C. (2.47 KPa)

 

 

 

Min. Manifold Press:

0.2 W.C. (0.05 KPa)

2.3 W.C. (0.57 KPa)

 

 

 

Max. Supply Press:

7.0 W.C. (1.74 KPa)

13.0 W.C. (3.28 KPa)

 

 

 

Min. Supply Press:

5.0 W.C. (1.24 KPa)

12.0 W.C. (2.96 KPa)

Max. Input:

26,600 BTU/hr

21,300 BTU/hr

 

(7.79 KW)

(6.24 KW)

 

 

 

Min. Input:

6,500 BTU/hr

11,400 BTU/hr

 

(1.9 KW)

(3.34 KW)

 

 

 

NEVER USE AN OPEN FLAME FOR LEAK TESTING.

27

Image 27
Contents Installer For Your SafetyConsumer General Safety PrecautionsTable of Contents Vented GAS Fireplace Heater Sonnet BV/DV NG/LPG Codes And ApprovalsDimensions SpecificationsTrimmable Lighting and Turning OFF Instructions Operating InstructionsAdjustment of Flame Height Setting the TimeSetting C/24 hour or F/12 hour Clock Automatic Pilot ModeSetting the Timer Changing the Mode of OperationMAN Mode Manual Flame Height Adjustment Setting the TemperatureComponent Sound & Reason Adjusting the venturi air settingPilot Flame Maintenance And ServiceReceiver Remote HandsetChanging Remote Handset Code Kit Parts List Conversion Kit InstallationOut of the firebox Each end that fit in to the brass nut but Mantle width and height Initial InstallationCan be started Vent Kit Installation Kit Contents Quantity DescriptionUnit Sheet metal screws evenly spaced KIT Components Installation InstructionsProper flame appearance. The amount of air Wall Bracket Top & Bottom Tools Required Fan wiring diagramInstalling Power Cord Fan Kit InstallationGas Line Connection Grounding Power CordOpening Inlet Pressure Tap on To Test Valve PressuresSecondary Installation InstallationKit Contents Screw Hook Bracket To the Trim AssemblyMinimum size of Large Removal InstallationEnsure the Sonnet is turned off and allow the unit to cool Hook PlacementsEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Never operate the fireplace with the glass door removed Log Set and Ember InstallationProblem Possible Cause Solution Trouble ShootingValve’s Safety Possible Cause SolutionNumber Parts List ComponentsBV only Part DescriptionReference Part Description Part Number ComponentsDiagramParts Parts List Options Parts Diagram OptionsReference Option Description Part Number To the Dealer WarrantyWarranty Installation Data Sheet