Enviro Sonnet, C-11089 owner manual Minimum size of Large

Page 30

Secondary Installation

 

Required Width

Adjustable

Adjustable

Surround Corner

Surround Corner

 

B/2

 

B

Required

 

Height

 

 

Trim (Classic or Colonial)

 

A

 

Note: Mounting brackets

 

removed for clarity

Figure 61: Marking offsets on Trim, Relates to Table 7.

b)Subtract the minimum size of the surround (2313/16” (555mm) x 317⁄8” (809mm) for the small and 241/16” (612mm) x 361⁄4” (921mm) for the large) from the size needed. Write down the difference. In the

Table 7: Adjustable Surround Example, Relates to Figure 61.

 

Height

Width

 

 

 

Area Needed to Cover

251/16” (637mm)

391⁄4” (997mm)

Minimum size of Large

241/16” (612mm)

361⁄4” (921mm)

Adjustable Surround

 

 

Difference

1” (25mm) = A

3” (76mm) = B

 

 

 

Figure 62: Installing Mounting Bracket.

Table 7 example, the differences are 1” (25mm) and 3” (76mm).

c)Mark the height difference on the left and right trim sides. Using the example, they would be marked 1” (25mm) from the bottom of each side, see dimension “A” in Figure 61.

d)Mark the center of the top trim, 155⁄8” (397mm) from either side. From the center line mark half the width distance on either side. Using the example of 3” (76mm), there would be marks 11⁄2” (38mm) on either side of the center line, see dimension “B/2” in Figure 61.

9.Fasten a mounting bracket to each of the four (4) mounting bracket backs using two (2) #8 T-20 screws (see Figure 62). They should be tight enough that they hold together but loose enough to slide them in the slots.

10.Line the ends of the surround corners with the marks from step 8. Move the mounting brackets until the holes on the surround line up with the slots on the mounting brackets. When everything is lined up, secure the surround to the mounting brackets with eight (8) #8 T-20 screws (see Figure 63). Also tighten the eight (8) screws from step 9.

30

Image 30
Contents Installer For Your SafetyConsumer Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sonnet BV/DV NG/LPGSpecifications DimensionsTrimmable Operating Instructions Lighting and Turning OFF InstructionsAutomatic Pilot Mode Setting the TimeSetting C/24 hour or F/12 hour Clock Adjustment of Flame HeightSetting the Temperature Changing the Mode of OperationMAN Mode Manual Flame Height Adjustment Setting the TimerAdjusting the venturi air setting Component Sound & ReasonMaintenance And Service Pilot FlameRemote Handset ReceiverChanging Remote Handset Code Kit Parts List Conversion Kit InstallationOut of the firebox Each end that fit in to the brass nut but Initial Installation Mantle width and heightCan be started Kit Contents Quantity Description Vent Kit InstallationUnit Sheet metal screws evenly spaced Installation Instructions KIT ComponentsProper flame appearance. The amount of air Wall Bracket Top & Bottom Fan wiring diagram Tools RequiredFan Kit Installation Installing Power CordGrounding Power Cord Gas Line ConnectionTo Test Valve Pressures Opening Inlet Pressure Tap onSecondary Installation InstallationKit Contents Assembly Screw Hook Bracket To the TrimMinimum size of Large Installation RemovalHook Placements Ensure the Sonnet is turned off and allow the unit to coolEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Log Set and Ember Installation Never operate the fireplace with the glass door removedTrouble Shooting Problem Possible Cause SolutionPossible Cause Solution Valve’s SafetyPart Description Parts List ComponentsBV only NumberReference Part Description Part Number ComponentsDiagramParts Parts List Options Parts Diagram OptionsReference Option Description Part Number Warranty To the DealerWarranty Installation Data Sheet