Enviro C-11089 Codes And Approvals, Vented GAS Fireplace Heater Sonnet BV/DV NG/LPG

Page 4

Codes And Approvals

DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.

This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimney liner kit.

This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (SONNET BV/DV; NG/LPG)

TESTED TO: ANSI Z21.88-2005/CSA 2.33-2005 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO Sonnet Fireplace:

Has been certified for use with either natural or propane gases. (See rating label.)

Is not for use with solid fuels.

Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a permanent wall thermostat for bedroom installations is required. The remote handset included with this unit has a thermostat in its control

system and a design feature that will turn the main burner off if there is a ‘no communicate’ condition caused by the handset being removed from the normal range of operation (up to 20-25ft (6.1-

7.6m)) or a low battery condition in either the receiver or the hand set. Consult the authority having local jurisdiction in your area. IN USA: see current ANSI Z223.1 for installation instructions.)

Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

Is not approved for closet or recessed installations.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the first burn, turn the unit off, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer. See “DOOR REMOVAL” and “CLEANING THE GLASS” sections.

4

Image 4
Contents For Your Safety InstallerConsumer Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sonnet BV/DV NG/LPGSpecifications DimensionsTrimmable Operating Instructions Lighting and Turning OFF InstructionsSetting the Time Setting C/24 hour or F/12 hour ClockAutomatic Pilot Mode Adjustment of Flame HeightChanging the Mode of Operation MAN Mode Manual Flame Height AdjustmentSetting the Temperature Setting the TimerAdjusting the venturi air setting Component Sound & ReasonMaintenance And Service Pilot FlameRemote Handset ReceiverChanging Remote Handset Code Conversion Kit Installation Kit Parts ListOut of the firebox Each end that fit in to the brass nut but Initial Installation Mantle width and heightCan be started Kit Contents Quantity Description Vent Kit InstallationUnit Sheet metal screws evenly spaced Installation Instructions KIT ComponentsProper flame appearance. The amount of air Wall Bracket Top & Bottom Fan wiring diagram Tools RequiredFan Kit Installation Installing Power CordGrounding Power Cord Gas Line ConnectionTo Test Valve Pressures Opening Inlet Pressure Tap onInstallation Secondary InstallationKit Contents Assembly Screw Hook Bracket To the TrimMinimum size of Large Installation RemovalHook Placements Ensure the Sonnet is turned off and allow the unit to coolEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Log Set and Ember Installation Never operate the fireplace with the glass door removedTrouble Shooting Problem Possible Cause SolutionPossible Cause Solution Valve’s SafetyParts List Components BV onlyPart Description NumberReference Part Description Part Number ComponentsDiagramParts Parts Diagram Options Parts List OptionsReference Option Description Part Number Warranty To the DealerWarranty Installation Data Sheet