Enviro Sonnet, C-11089 owner manual Remote Handset, Receiver

Page 12

Maintenance And Service

GLASS DOOR REMOVAL:

Remove the glass door by placing the hooked end of the door release tool in the hole on the door latch mechanism (see Figure 9) and pulling the latch

out then up over the lip on the door. When the two (2) latches have been released, tilt the door forward and then lift up to unhook the bottom door tabs (see Figure 10).

Figure 9: Door Release.

Warning: Do not touch or attempt to remove the glass if the fireplace is not completely cold. Never operate the fireplace with the glass removed.

Figure 10: Door Removal.

CAUTION GLASS MAY SEPARATE FROM DOOR.

CLEANING THE PAINTED SURFACES:

Painted faces should be wiped with a damp cloth periodically.

REPLACING THE BATTERIES:

It is recommended that the batteries are replaced at the beginning of each heating season. Batteries must be changed when an acoustic error message is heard. Do not use metallic tooling to remove the batteries as it could cause a short that may render

the receiver inoperable.

Table 3: Batteries Required for Sonnet.

Figure 11: Control Panel Removal.

 

Quantity

Type of Battery

 

 

 

Receiver

4

1.5V “AA” (quality

alkaline recommended)

 

 

 

 

 

Remote

1

9V (quality alkaline

Handset

recommended)

 

Remote Handset:

Remove handset backing, replace the 9V battery, and re-install handset backing (see Figure 13).

Receiver:

1.Unplug the power or turn off the electrical breaker for the unit.

2.Pull the control panel straight out (see Figure 11). There are two (2) tabs on the bottom of the panel that fit in two (2) slots in the Sonnet cabinet bottom.

3.Pull the battery bracket to the left and forward; it will pivot out (see Figure 11 & 12).

4.Replace the four (4) 1.5V “AA” batteries and reverse steps 2 and 3.

5.Plug the unit in or turn on the electrical breaker for the unit.

Figure 12: Battery Clip on

Bracket.

12

Image 12
Contents Installer For Your SafetyConsumer Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sonnet BV/DV NG/LPGSpecifications DimensionsTrimmable Operating Instructions Lighting and Turning OFF InstructionsSetting the Time Setting C/24 hour or F/12 hour ClockAutomatic Pilot Mode Adjustment of Flame HeightChanging the Mode of Operation MAN Mode Manual Flame Height AdjustmentSetting the Temperature Setting the TimerAdjusting the venturi air setting Component Sound & ReasonMaintenance And Service Pilot FlameRemote Handset ReceiverChanging Remote Handset Code Kit Parts List Conversion Kit InstallationOut of the firebox Each end that fit in to the brass nut but Initial Installation Mantle width and heightCan be started Kit Contents Quantity Description Vent Kit InstallationUnit Sheet metal screws evenly spaced Installation Instructions KIT ComponentsProper flame appearance. The amount of air Wall Bracket Top & Bottom Fan wiring diagram Tools RequiredFan Kit Installation Installing Power CordGrounding Power Cord Gas Line ConnectionTo Test Valve Pressures Opening Inlet Pressure Tap onSecondary Installation InstallationKit Contents Assembly Screw Hook Bracket To the TrimMinimum size of Large Installation RemovalHook Placements Ensure the Sonnet is turned off and allow the unit to coolEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Log Set and Ember Installation Never operate the fireplace with the glass door removedTrouble Shooting Problem Possible Cause SolutionPossible Cause Solution Valve’s SafetyParts List Components BV onlyPart Description NumberReference Part Description Part Number ComponentsDiagramParts Parts List Options Parts Diagram OptionsReference Option Description Part Number Warranty To the DealerWarranty Installation Data Sheet