Initial Installation

QUALIFIED INSTALLERS ONLY

VENTING FIREPLACE INSERTS:

The ENVIRO Sonnet may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. Before starting, refer to INITIAL INSTALLATION - PREPARING YOUR SONNET FOR

INSTALLATION and INITIAL INSTALLATION - CONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE. Please

reference the information in Table 5 and Figures 37, 38,and 41.

An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s instructions that accompany the chimney liner kit. Use listed B-Vent or Flexmaster double walled aluminum flex vent.

If necessary, remove the vent collar plate from the top of the insert and connect it securely to the liner with sheet metal screws and/or hose clamps. Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed.

Provide for proper and adequate venting and air supply for this appliance in accordance with the tables in the current National Fuel Gas Code, Z223.1/NFPA 54 or the CSA B149.1.

 

Table 5: Vent termination clearances

 

 

Minimum Clearance

Description

 

 

3 ft (0.9 m)

Clearance above the highest point where it passes through a roof surface, refer

to Figure 37.

 

24 in (0.6 m)

Clearance above a roof ridge, any other portion of a building, or any other ob-

struction within a horizontal distance of 10 feet (3 m), refer to Figure 37.

 

5 ft (1.5 m)

Clearance for a vent or chimney above either the highest connected appliance

drafthood outlet, or flue collar.

 

 

 

6 ft (1.83 m)

Clearance to mechanical air supply inlet.

 

 

3ft (0.9m)

Clearance to each side of center line extended above meter/regulator assembly.

 

 

6 ft (1.83 m)

Radial clearance around service regulator vent outlet.

 

 

12 in (30 cm)

Clearance above grade, verandah, porch, deck, or balcony.

 

 

 

Clearance to a building opening or combustion air inlet of another appliance,

3 ft (0.9 m)

except with the approval of the authority having jurisdiction for the following

 

reduced clearances.

9 in (0.23 m)

Exception for inputs up to and including 50,000 Btuh (15kW)

 

 

12 in (0.3 m)

Exception for inputs exceeding 50,000 Btuh (15kW) but not exceeding 100,000

Btuh (30kW)

 

 

 

NOTE: If the Sonnet unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant or silicone and reconnected with three

(3) sheet metal screws evenly spaced.

2ft (0.6m)

Roof ridge or

Minimum

3ft (0.9m)

any other portion

of a building

Minimum

Within

 

10ft (3m)

Figure 37: Roof Clearances.

20

Image 20
Contents Consumer InstallerFor Your Safety Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sonnet BV/DV NG/LPGSpecifications DimensionsTrimmable Operating Instructions Lighting and Turning OFF InstructionsSetting the Time Setting C/24 hour or F/12 hour ClockAutomatic Pilot Mode Adjustment of Flame HeightChanging the Mode of Operation MAN Mode Manual Flame Height AdjustmentSetting the Temperature Setting the TimerAdjusting the venturi air setting Component Sound & ReasonMaintenance And Service Pilot FlameRemote Handset ReceiverChanging Remote Handset Code Out of the firebox Kit Parts ListConversion Kit Installation Each end that fit in to the brass nut but Initial Installation Mantle width and heightCan be started Kit Contents Quantity Description Vent Kit InstallationUnit Sheet metal screws evenly spaced Installation Instructions KIT ComponentsProper flame appearance. The amount of air Wall Bracket Top & Bottom Fan wiring diagram Tools RequiredFan Kit Installation Installing Power CordGrounding Power Cord Gas Line ConnectionTo Test Valve Pressures Opening Inlet Pressure Tap onKit Contents Secondary InstallationInstallation Assembly Screw Hook Bracket To the TrimMinimum size of Large Installation RemovalHook Placements Ensure the Sonnet is turned off and allow the unit to coolEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Log Set and Ember Installation Never operate the fireplace with the glass door removedTrouble Shooting Problem Possible Cause SolutionPossible Cause Solution Valve’s SafetyParts List Components BV onlyPart Description NumberReference Part Description Part Number ComponentsDiagramParts Reference Option Description Part Number Parts List OptionsParts Diagram Options Warranty To the DealerWarranty Installation Data Sheet