Care and cleaning.

GEAppliances.com

Routine Preventive Maintenance

DANGER: Risk of Scald - Before manually operating the relief valve, make certain no one will be exposed to the danger of coming in contact with the hot water released by the valve. The water may be hot enough to create a scald hazard. The water should be released into a suitable drain to prevent injury or property damage.

NOTE: If the temperature and pressure-relief valve on the hot water heater discharges periodically, this may be due to thermal expansion in a closed water system. Contact the water supplier or your plumbing contractor on how to correct this. Do not plug the relief valve outlet.

3URSHUO\PDLQWDLQHG\RXUZDWHUKHDWHUZLOOSURYLGH\HDUVRI

GHSHQGDEOHWURXEOHIUHHVHUYLFH

,WLVVXJJHVWHGWKDWDURXWLQHSUHYHQWLYHPDLQWHQDQFHSURJUDPEH HVWDEOLVKHGDQGIROORZHGE\WKHXVHU

Temperature and Pressure-Relief Valve:

$WOHDVWRQFHD\HDUOLIWDQGUHOHDVHWKHOHYHUKDQGOHRQWKH

WHPSHUDWXUHDQGSUHVVXUHUHOLHIYDOYHORFDWHG

RQWKHIURQWULJKWVLGHRIWKHZDWHUKHDWHUWRPDNHFHUWDLQWKH YDOYHRSHUDWHVIUHHO\$OORZVHYHUDOJDOORQVWRIOXVKWKURXJKWKH

GLVFKDUJHOLQHWRDQRSHQGUDLQ

Periodic Inspection (once a year):

,WLVIXUWKHUUHFRPPHQGHGWKDWDSHULRGLFLQVSHFWLRQRIWKH RSHUDWLQJFRQWUROVKHDWLQJHOHPHQWVDQGZLULQJVKRXOGEHPDGH E\VHUYLFHSHUVRQQHO

TXDOLILHGLQHOHFWULFDSSOLDQFHUHSDLU

0RVWHOHFWULFDODSSOLDQFHVHYHQZKHQQHZPDNHVRPHVRXQG ZKHQLQRSHUDWLRQ,IWKHKLVVLQJRUVLQJLQJVRXQGOHYHOLQFUHDVHV H[FHVVLYHO\WKHHOHFWULFKHDWLQJHOHPHQWPD\UHTXLUHFOHDQLQJ

&RQWDFWDTXDOLILHGLQVWDOOHURUSOXPEHUIRULQVSHFWLRQ

Flushing Tank

$ZDWHUKHDWHU·VWDQNFDQDFWDVDVHWWOLQJEDVLQ

IRUVROLGVVXVSHQGHGLQWKHZDWHU,WLVWKHUHIRUHQRWXQFRPPRQ IRUKDUGZDWHUGHSRVLWVWRDFFXPXODWHLQWKHERWWRPRIWKHWDQN 7RFOHDQWKHWDQNRIWKHVHGHSRVLWVIROORZWKHVHVWHSV $WWDFKDJDUGHQKRVHWRWKHGUDLQYDOYHORFDWHGDWWKHERWWRP

RIWKHXQLWDQGGLUHFWWKDWKRVHWRDGUDLQ

2SHQWKHGUDLQYDOYHZLWKDIODWVFUHZGULYHU

2QFHDIHZTXDUWVRIZDWHUKDYHEHHQGUDLQHGFORVHWKHGUDLQ

YDOYH

7KLVVKRXOGEHGRQHZLWKWKHFROGZDWHUVXSSO\RSHQVXFKWKDW

ZDWHUUHPRYHGWKURXJKGUDLQYDOYHLVUHSODFHGDQGZDWHUVXSSO\ IORZKHOSVWRUHPRYHVHGLPHQW

Draining the Water Heater

CAUTION: Risk of Shock - Shut off power to the water heater before draining water.

DANGER: Risk of Scald - Before manually operating the relief valve, make certain no one will be exposed to the hot water released by the valve. The water drained from the tank may be hot enough to present a scald hazard and should be directed to a suitable drain to prevent injury or damage.

7RGUDLQWKHZDWHUKHDWHUIROORZWKHVHVWHSV

$WWDFKDJDUGHQKRVHWRWKHGUDLQYDOYHORFDWHGDWWKH ERWWRPRIWKHXQLWDQGGLUHFWWKDWKRVHWRDGUDLQ

7XUQRȺWKHFROGZDWHUVXSSO\

$GPLWDLUWRWKHWDQNE\RSHQLQJDKRWZDWHUIDXFHWRU

OLIWLQJWKHKDQGOHRQWKHUHOLHIYDOYH 2SHQWKHGUDLQYDOYHZLWKDÀDWVFUHZGULYHU

1RWH6HHSDJHIRUSURGXFWVFKHPDWLF

Use a flat slot screwdriver to turn valve.

Extended Shutdown Periods or Vacations Exceeding Vacation Mode Options

,IWKHZDWHUKHDWHULVWRUHPDLQLGOHIRUDQH[WHQGHGSHULRGRI WLPHWKHSRZHUDQGZDWHUWRWKHDSSOLDQFHVKRXOGEHWXUQHG

RIIWRFRQVHUYHHQHUJ\DQGSUHYHQWDEXLOGXSRIGDQJHURXV K\GURJHQJDV7KLVXQLWKDVQRSRZHUEXWWRQSRZHUFDQRQO\

EHVKXWRIIDWWKHFLUFXLWEUHDNHURUGLVFRQQHFWVZLWFK

7KHZDWHUKHDWHUDQGSLSLQJVKRXOGEHGUDLQHGLIWKH\PLJKW

EHVXEMHFWHGWRIUHH]LQJWHPSHUDWXUHV

$IWHUDORQJVKXWGRZQSHULRGWKHZDWHUKHDWHU·VRSHUDWLRQ

DQGFRQWUROVVKRXOGEHFKHFNHGE\TXDOLILHGVHUYLFH

SHUVRQQHO0DNHFHUWDLQWKHZDWHUKHDWHULVFRPSOHWHO\ILOOHG

DJDLQEHIRUHSODFLQJLWLQRSHUDWLRQ

NOTE: Refer to the Hydrogen Gas Caution in the Operating Instructions (see page 3).

11

Image 11
Contents 49-50292-1 08-13 GE Important Safety InformationGEAppliances.com Operating InstructionsIXUWKHULQIRUPDWLRQ Time/Temperature Relationship in ScaldsTemperature Time to Produce a Serious Burn TXDOL¿HGVHUYLFHWHFKQLFLDQRUWKHORFDOHOHFWULFXWLOLW\GEAppliances.com GHIHFWVRURWKHUUHSURGXFWLYHKDUP7XUQRIIWKHSRZHUWRWKHZDWHUKHDWHU Safety PrecautionsSafety Controls To reset the temperature-limiting controlAbout the control panel.  Control FeaturesSURYLGHHYHQJUHDWHUHQHUJ\VDYLQJV Turning on the water heater.Time/Temperature Relationship in Scalds About the water temperature settingTo Adjust the Temperature High Demand/Boost Hybrid ModeTo access any of these modes Operational Modes. Operation Frequently Asked Questions.Filter ModesLQWKHLQVWUXFWLRQVWKDWFRPHZLWKWKHPRGXOH Appliance Communication Module where installed. KHQWKH ‡´+LJKµ UHSUHVHQWVLQFUHDVHGHQHUJ\FRVWUDWH Draining the Water Heater Care and cleaningRoutine Preventive Maintenance Exterior Surfaces Care and cleaning of the water heaterCleaning the Filter Clearing the Condensation Drain TubeOOXVWUDWLRQ$ Anode Rod Maintenance and Service7RROVQHHGHG 7RVHUYLFHWKH$QRGH5RG5HVLGHQWDODWHU+HDWHU6LLQJ*XLGH $87,21Risk of Property Damage$75+$756,=,1*,1250$7,215$ %25,167$//,1* FRQVLGHUDWLRQWKHIROORZLQJDWFK3DQ,QVWDOODWLRQ ,IUHTXLUHG 5HTXLUHGFOHDUDQFHVEliminate potential water damage GLVFRQQHFWHGIRUVHUYLFLQJLIQHFHVVDU\73,&$/,167$//$7,21 Condensate drain pump not240V Junction box cover L1 Black LQGLFDWHVDIXOOZDWHUKHDWHUSURYLGHGIRUILHOGZLULQJFRQQHFWLRQV ZDWHUKHDWHUWKHHWHULRURIWKHLQVXODWLRQEODQNHW XQDXWKRULHGGHYLFHVFRQQHFWLRQV 7KHPDQXIDFWXUHU·VZDUUDQW\GRHVQRWFRYHUDQ\&RQGHQVDWHOLQHVDUHLQSODFH ++$FWLRQV DQNORFDWLRQ Troubleshooting… For Service, please call 1.888.4GE.HEWH Troubleshooting…Rqglwlrq $FWLRQ Fault codesFor The Period Of We Will Replace GE Hybrid Water Heater WarrantyWhat Is Not Covered Entretien et nettoyage Instructions d’InstallationImportantes consignes Consignes d’utilisationTemps pour produire une brûlure grave Relation température/temps pour les brûluresTempérature Pour Installations Dans L’ÉTAT DE Californie Précautions de sécurité Commandes de sécuritéPour réinitialiser la commande de limitation de température Mise EN Garde La cause de laCommandes Fonctions Au sujet des commandes panneau0LVHHQPDUFKHGXFKDXȺHHDX Pour régler la température de l’eau Au sujet du réglage de la température de l’eauRelation température/temps pour les brûlures Vacances Mode HybrideModes opérationnels Demande élevée/Demande optimaleFonctionnement Foire aux questionsFiltre ACM Module de communication de l’appareil si installéInspection périodique une fois par an Entretien et nettoyageEntretien préventif Soupape de sécurité température et pressionLaver à la main avec de l’eau tiède seulement Débouchage du tuyau de vidange de la condensationSurfaces Extérierures Tige d’anodePour réparer la tige d’anode Entretien et réparation de la tige d’anodeOutils requis ‡/HFKDXȺHHDXK\EULGH*HR6SULQJŒSHXWUHPSODFHUXQ EmplacementEmplacement Suite Point de réglage de la températureTuyau de vidange du condensat Pièces NON Standard RequisesExpansion Thermique Dégagements nécessaires%WXK  Water Supply ConnectionsSoupape DE Securite Tuyau DE Vidange DU CondensatFKDXȺHHDXSOHLQ Remplissage DU CHAUFFE-EAURaccordements Électriques Le câblage du circuit de dérivation doit inclure000 500 10,000 11,000 12,000 FKDXȺDQWV‡1HFRXYUHSDVOHVSDQQHDXG·DFFqVDXpOpPHQWV 000Tuyaux pour les condensats sont en place Liste DE Vérification D’INSTALLATIONEmplacement du réservoir Temps écoulé Actions Hewh RemarquesProblème Causes Possibles Solution Dépannage… Pour obtenir un service, appelez le 1.888.4GE.HEWHCertains modèles Condition Action6XUFKDXȺHWURSIDLEOH ¿OWUHHVWVDOHDe la Deuxième à Pour la période d’ Nous remplaceronsCe qui n’est pas compris Un AnProlongation de garantie Soutien au consommateur Service de réparations67-69 Instrucciones de InstalaciónInformación Importante de Consejos para SolucionarGHUHGXFLUHOULHVJRGHOHVLRQHVSRUTXHPDGXUDV Relación de Tiempo/ Temperatura en QuemadurasNota Los hogares donde haya niños pequeños, personas ¡PRECAUCIÓN 3UHVLRQHHOERWyQURMRGH5,1,&,2 Precauciones de SeguridadControles de Seguridad Para reiniciar el control de límite de temperaturaControles Funciones Acerca de los controlesLOXPLQDGR Encendido del calentador de aguaRelación de Tiempo/ Temperatura en Quemaduras Para Ajustar la TemperaturaModo Eléctrico/ Estándar Ventilador apagado Modos de FuncionamientoModo Híbrido Alta Demanda/ IncrementoFRQGLFLRQHVORSHUPLWDQ Preguntas FrecuentesFiltro Funcionamiento ¢3RUTXpKD\XQ¿OWUR Modos $KRUURGHQHUJtD  SDQWDOODVHYLVXDOLDUiHQFXHQWUDQHQODVLQVWUXFFLRQHVLQFOXLGDVFRQHOPyGXOR VREUHHOSURGXFWRPurga del Tanque Cuidado y limpiezaDrenaje del Calentador de Agua Inspección Periódica XQDYHSRUDxR Varilla del Ánodo Cuidado y limpieza del calentador de aguaLimpieza del Filtro Limpieza de la Tubería de Drenaje de CondensaciónIlustración a To service the Anode Rod752 $1,//2/ %25 $%/6 $5,//$/È122Para instalaciones en construcciones nuevas Requisitos DE ElectricidadUbicación Para reemplazos en viviendas existentesDrenaje de condensación Piezas no Estándares NecesariasThermal Expansion Despejes requeridosIURQWDOGHOFDOHQWDGRU ZDWW %78+  Válvula DE AlivioVHLQGLFDHQODSODFDGHFDOL¿FDFLyQ PDQWHQLPLHQWRGHODXQLGDGHQIRUPDSRVWHULRUDFHSWDEOHV Conexiones EléctricasEl cableado de circuito derivado debería incluir ODXQLGDGREVHUYDGRPiVDUULEDDXWRULDGRV Guía DE Tamaños Para Circuitos DerivadosVXSHULRUHVRWUDVHUDVGHODXQLGDG SURSLHGDGTiempo Acciones Hewh Comentarios Transcurrido Lista DE Control DE LA InstalaciónQUÉ Esperar Para UN Comienzo Normal EN EL Modo Híbrido Problema Causas Posibles Qué Hacer Solución de Problemas…68RU6HUYLFHSOHDVHFDOO*++  Códigos de falla Problema Causas Posibles Qué Hacer2QHHDU +\EULGDWHU+HDWHUDUUDQW\GEAppliances.com Soporte al consumidor&DQDGDFDOO Consumer Support