*(+\EULG:DWHU+HDWHU:DUUDQW\

$OOZDUUDQW\VHUYLFHSURYLGHGE\RXU$XWKRUL]HG6HUYLFHU1HWZRUN 7RVFKHGXOHVHUYLFHFDOO*(+(:+  3OHDVH

KDYHVHULDOQXPEHUDQGPRGHOQXPEHUDYDLODEOH ZKHQFDOOLQJIRU VHUYLFH

6WDSOH\RXUUHFHLSWKHUH

3URRIRIWKHRULJLQDOSXUFKDVH

GDWHLVQHHGHGWRREWDLQ

VHUYLFHXQGHUWKHZDUUDQW\

 

)RU7KH3HULRG2I

:H:LOO5HSODFH

 

2QH<HDU

$Q\SDUWRIWKH+\EULG:DWHU+HDWHUZKLFKIDLOVGXHWRDGHIHFWLQPDWHULDOVRUZRUNPDQVKLS

 

)URPWKHGDWHRIWKH

'XULQJWKLVlimited one-year warranty,*(ZLOODOVRSURYLGHfree of charge,DOOODERUDQGUHODWHG

 

RULJLQDOSXUFKDVH

VHUYLFHWRUHSODFHWKHGHIHFWLYHSDUW

 

 

 

 

Second through

Any partRIWKH+\EULG:DWHU+HDWHUZKLFKIDLOVGXHWRDGHIHFWLQPDWHULDOVRUZRUNPDQVKLS

 

7HQWK<HDU

'XULQJWKLVlimited ten-year parts warranty,ODERUDQGUHODWHGVHUYLFHWRUHSODFHWKH

 

)URPWKHGDWHRIWKH

GHIHFWLYHSDUWDUHQRWLQFOXGHG

 

RULJLQDOSXUFKDVH

 

:KDW,V1RW&RYHUHG

„Service trips to your home to teach you how to use the product.

„Improper installation, delivery or maintenance.

„Failure of the product if it is abused, misused, altered, used commercially or used for other than the intended purpose.

„Use of this product where water is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system.

„Replacement of house fuses or resetting of circuit breakers.

„Damage to the product caused by accident, lightning, fire, flood or acts of God.

„Incidental or consequential damage caused by possible defects with this appliance, its installation or repair.

„Product not accessible to provide required service in a safe manner. Attic installation must have flooring and accessible stairs.

„If product removed from original installation location.

„Damages, malfunctions or failure caused by the use of repair service not approved by GE.

„Damages, malfunctions or failure caused by the use of unapproved parts or components.

„Damages, malfunctions or failure caused by operating the heat pump water heater with the anode rod removed.

„Consumo y reemplazo de la varilla del ánodo.

„Damages, malfunctions or failure resulting from operating the heat pump with an empty or partially empty tank.

„Damages, malfunctions or failure caused by subjecting the tank to pressure greater than those shown on the rating label.

„Damages, malfunctions or failure caused by operating the heat pump water heater with electrical voltage outside the voltage range listed on the rating label.

„Water heater failure due to the water heater being operated in a corrosive atmosphere.

(;&/86,212),03/,(':$55$17,(6³<RXUVROHDQGH[FOXVLYHUHPHG\LVSURGXFWUHSDLUDVSURYLGHGLQ

tKLV/LPLWHG:DUUDQW\$Q\LPSOLHGZDUUDQWLHVLQFOXGLQJWKHLPSOLHGZDUUDQWLHVRIPHUFKDQWDELOLW\RU fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

7KLVZDUUDQW\LVH[WHQGHGWRWKHRULJLQDOSXUFKDVHUDQGDQ\VXFFHHGLQJRZQHUIRUSURGXFWVSXUFKDVHGIRUKRPH XVHZLWKLQWKH86$,IWKHSURGXFWLVORFDWHGLQDQDUHDZKHUHVHUYLFHE\D*($XWKRUL]HG6HUYLFHULVQRWDYDLODEOH \RXPD\EHUHVSRQVLEOHIRUDWULSFKDUJHRU\RXPD\EHUHTXLUHGWREULQJWKHSURGXFWWRDQ$XWKRUL]HG*(6HUYLFH ORFDWLRQIRUVHUYLFH,Q$ODVNDWKHZDUUDQW\H[FOXGHVWKHFRVWRIVKLSSLQJRUVHUYLFHFDOOVWR\RXUKRPH

6RPHVWDWHVGRQRWDOORZWKHH[FOXVLRQRUOLPLWDWLRQRILQFLGHQWDORUFRQVHTXHQWLDOGDPDJHV7KLVZDUUDQW\ JLYHV\RXVSHFLILFOHJDOULJKWVDQG\RXPD\DOVRKDYHRWKHUULJKWVZKLFKYDU\IURPVWDWHWRVWDWH7RNQRZ ZKDW\RXUOHJDOULJKWVDUHFRQVXOW\RXUORFDORUVWDWHFRQVXPHUDIIDLUVRIILFHRU\RXUVWDWH·V$WWRUQH\*HQHUDO

)RUSURGXFWSXUFKDVHGRXWVLGHRIWKH86FRQWDFW\RXUGHDOHUIRU:DUUDQW\DQG6HUYLFHLQIRUPDWLRQ

:DUUDQWRUIRU3URGXFWV3XUFKDVHGLQWKH8QLWHG6WDWHV*HQHUDO(OHFWULF&RPSDQ\/RXLVYLOOH.<

70

Image 70
Contents Operating Instructions Important Safety InformationGEAppliances.com 49-50292-1 08-13 GETXDOL¿HGVHUYLFHWHFKQLFLDQRUWKHORFDOHOHFWULFXWLOLW\ Time/Temperature Relationship in ScaldsTemperature Time to Produce a Serious Burn IXUWKHULQIRUPDWLRQGHIHFWVRURWKHUUHSURGXFWLYHKDUP GEAppliances.comTo reset the temperature-limiting control Safety PrecautionsSafety Controls 7XUQRIIWKHSRZHUWRWKHZDWHUKHDWHUControl Features About the control panel. Turning on the water heater. SURYLGHHYHQJUHDWHUHQHUJ\VDYLQJVTo Adjust the Temperature About the water temperature settingTime/Temperature Relationship in Scalds Operational Modes.  Hybrid ModeTo access any of these modes High Demand/BoostModes Frequently Asked Questions.Filter Operation‡´+LJKµ UHSUHVHQWVLQFUHDVHGHQHUJ\FRVWUDWH Appliance Communication Module where installed. KHQWKH LQWKHLQVWUXFWLRQVWKDWFRPHZLWKWKHPRGXOHRoutine Preventive Maintenance Care and cleaningDraining the Water Heater Clearing the Condensation Drain Tube Care and cleaning of the water heaterCleaning the Filter Exterior Surfaces7RVHUYLFHWKH$QRGH5RG Anode Rod Maintenance and Service7RROVQHHGHG OOXVWUDWLRQ$FRQVLGHUDWLRQWKHIROORZLQJ $87,21Risk of Property Damage$75+$756,=,1*,1250$7,215$ %25,167$//,1* 5HVLGHQWDODWHU+HDWHU6LLQJ*XLGH5HTXLUHGFOHDUDQFHV DWFK3DQ,QVWDOODWLRQ ,IUHTXLUHG Condensate drain pump not GLVFRQQHFWHGIRUVHUYLFLQJLIQHFHVVDU\73,&$/,167$//$7,21 Eliminate potential water damageZDWHUKHDWHU LQGLFDWHVDIXOOZDWHUKHDWHUSURYLGHGIRUILHOGZLULQJFRQQHFWLRQV 240V Junction box cover L1 Black7KHPDQXIDFWXUHU·VZDUUDQW\GRHVQRWFRYHUDQ\ XQDXWKRULHGGHYLFHVFRQQHFWLRQV WKHHWHULRURIWKHLQVXODWLRQEODQNHW DQNORFDWLRQ ++$FWLRQV&RQGHQVDWHOLQHVDUHLQSODFH Troubleshooting… Troubleshooting… For Service, please call 1.888.4GE.HEWHFault codes Rqglwlrq $FWLRQWhat Is Not Covered GE Hybrid Water Heater WarrantyFor The Period Of We Will Replace Consignes d’utilisation Instructions d’InstallationImportantes consignes Entretien et nettoyageTempérature Relation température/temps pour les brûluresTemps pour produire une brûlure grave Pour Installations Dans L’ÉTAT DE Californie Mise EN Garde La cause de la Commandes de sécuritéPour réinitialiser la commande de limitation de température Précautions de sécuritéAu sujet des commandes panneau Commandes Fonctions0LVHHQPDUFKHGXFKDXȺHHDX Relation température/temps pour les brûlures Au sujet du réglage de la température de l’eauPour régler la température de l’eau Demande élevée/Demande optimale Mode HybrideModes opérationnels VacancesFiltre Foire aux questionsFonctionnement Module de communication de l’appareil si installé ACMSoupape de sécurité température et pression Entretien et nettoyageEntretien préventif Inspection périodique une fois par anTige d’anode Débouchage du tuyau de vidange de la condensationSurfaces Extérierures Laver à la main avec de l’eau tiède seulementOutils requis Entretien et réparation de la tige d’anodePour réparer la tige d’anode Point de réglage de la température EmplacementEmplacement Suite ‡/HFKDXȺHHDXK\EULGH*HR6SULQJŒSHXWUHPSODFHUXQDégagements nécessaires Pièces NON Standard RequisesExpansion Thermique Tuyau de vidange du condensatTuyau DE Vidange DU Condensat Water Supply ConnectionsSoupape DE Securite %WXK Le câblage du circuit de dérivation doit inclure Remplissage DU CHAUFFE-EAURaccordements Électriques FKDXȺHHDXSOHLQ000 FKDXȺDQWV‡1HFRXYUHSDVOHVSDQQHDXG·DFFqVDXpOpPHQWV 000 500 10,000 11,000 12,000Temps écoulé Actions Hewh Remarques Liste DE Vérification D’INSTALLATIONEmplacement du réservoir Tuyaux pour les condensats sont en placeProblème Causes Possibles Solution Pour obtenir un service, appelez le 1.888.4GE.HEWH Dépannage…¿OWUHHVWVDOH Condition Action6XUFKDXȺHWURSIDLEOH Certains modèlesUn An Pour la période d’ Nous remplaceronsCe qui n’est pas compris De la Deuxième àSoutien au consommateur Service de réparations Prolongation de garantieConsejos para Solucionar Instrucciones de InstalaciónInformación Importante de 67-69Nota Los hogares donde haya niños pequeños, personas Relación de Tiempo/ Temperatura en QuemadurasGHUHGXFLUHOULHVJRGHOHVLRQHVSRUTXHPDGXUDV ¡PRECAUCIÓN Para reiniciar el control de límite de temperatura Precauciones de SeguridadControles de Seguridad 3UHVLRQHHOERWyQURMRGH5,1,&,2Acerca de los controles Controles FuncionesEncendido del calentador de agua LOXPLQDGRPara Ajustar la Temperatura Relación de Tiempo/ Temperatura en QuemadurasAlta Demanda/ Incremento Modos de FuncionamientoModo Híbrido Modo Eléctrico/ Estándar Ventilador apagadoModos Preguntas FrecuentesFiltro Funcionamiento ¢3RUTXpKD\XQ¿OWUR FRQGLFLRQHVORSHUPLWDQVREUHHOSURGXFWR SDQWDOODVHYLVXDOLDUiHQFXHQWUDQHQODVLQVWUXFFLRQHVLQFOXLGDVFRQHOPyGXOR $KRUURGHQHUJtD Inspección Periódica XQDYHSRUDxR Cuidado y limpiezaDrenaje del Calentador de Agua Purga del TanqueLimpieza de la Tubería de Drenaje de Condensación Cuidado y limpieza del calentador de aguaLimpieza del Filtro Varilla del Ánodo$%/6 $5,//$/È122 To service the Anode Rod752 $1,//2/ %25 Ilustración aPara reemplazos en viviendas existentes Requisitos DE ElectricidadUbicación Para instalaciones en construcciones nuevasDespejes requeridos Piezas no Estándares NecesariasThermal Expansion Drenaje de condensaciónPDQWHQLPLHQWRGHODXQLGDGHQIRUPDSRVWHULRU Válvula DE AlivioVHLQGLFDHQODSODFDGHFDOL¿FDFLyQ IURQWDOGHOFDOHQWDGRU ZDWW %78+ ODXQLGDGREVHUYDGRPiVDUULED Conexiones EléctricasEl cableado de circuito derivado debería incluir DFHSWDEOHVSURSLHGDG Guía DE Tamaños Para Circuitos DerivadosVXSHULRUHVRWUDVHUDVGHODXQLGDG DXWRULDGRVQUÉ Esperar Para UN Comienzo Normal EN EL Modo Híbrido Lista DE Control DE LA InstalaciónTiempo Acciones Hewh Comentarios Transcurrido Solución de Problemas… Problema Causas Posibles Qué Hacer68RU6HUYLFHSOHDVHFDOO*++  Problema Causas Posibles Qué Hacer Códigos de falla+\EULGDWHU+HDWHUDUUDQW\ 2QHHDUSoporte al consumidor GEAppliances.comConsumer Support &DQDGDFDOO