Flush Wall Installation
FINISHED WALL
3! OF
FRONT TRIM OR NON- COMBUSTIBLE MA TERIAL (INSTALLA TION IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
Figure 12
Combustible Surround Installation
Attention:Coldclimateinstallationrecommendation:
When installing this unit against a
Vent Runs (Figures 14, 15, 16, 17 and 18)
In planning the installation for the fireplace, it is necessary to install certain components before the appliance is completely positioned and installed. These include the direct vent system, gas piping for the appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1.A flat, hard combustible (burnable) surface.
2.A raised wooden platform.
3.Four (4) corner supports. (Example: Four (4) concrete masonry blocks.) These supports must be positioned so they contact all four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL
TERMINATION
2 X 4 HEADER
STAND OFF
MANTELSHELF
COMBUSTIBLE SURROUND
FINISHED WALL
3! OF
JOINT BETWEEN FINISHED WALL AND UNIT SEALED WITH 300° F 149° C SEALANT MATERIAL (SEALANT IS OPTIONAL)
DVP42, 48
49 ½”(126 mm)
TO BOTTOM
OF UNIT
VENT CAP/
THIMBLE
/
THIMBLE
Figure 14
Figure 13
Page 12 |