REAR VENT CONVERSION
VERTICAL VENTING
Note: It is recommended that the flue cover plate tab be pulled outward prior to removal.
This will ensure that the plate is not accidentally dropped inside the rear air chamber.
FLUE COVER PLATE
(See note above)
INLET VENT COVER PLATE
Note: Discard insulation
&retainer when venting off top of fireplace.
Note: Discard insulation
&retainer when using vertical venting off
INLET VENT COLLAR
FLUE OUTLET
COLLAR
HORIZONTAL VENTING
INLET VENT
COVER PLATE
FLUE COVER PLATE
FLUE INSULATION
INSULATION
RETAINER
INLET VENT COLLAR
Converting flue take-off to rear venting
When switching out the flue and inlet vent collars to run horizontally off the rear vent, the following steps must be taken.
1.Remove the inlet vent collar (8 screws) and flue collar (4 screws) from the top of the fireplace, and set to the side.
2.Remove the inlet cover plate and flue cover plate located on the back of the fireplace. These will be used to close the top flue and inlet openings.
3.Insert the insulation retainer bracket and insulation into the top flue pipe before reinstalling the flue cover plate over the
top flue with 4 screws.
4.Reinstall the inlet cover plate over the top inlet opening with 4 screws. See illustration above..
5.Install the flue collar assembly to the rear flue with 4 screws.
6.Install the inlet vent collar to the rear of the fireplace with 8 screws.
7.This completes the conversion for a rear vent application.
Note: for top vented installations, the insulation and retainer are to be removed from the flue pipe and discarded.
VENT SYSTEMS
The following vent systems are acceptable for use with the DVP series fireplaces:
Simpson Duravent® GS 5" - 8"
American Metal Products 5" - 8" Selkirk
Empire Flexvent Kit(s) (Magnaflex) 5" - 8"
Page 9 |