FRAMING AND FINISHING (continued)
Figure 39 | Figure 41 | |
See Horizontal Termination Page 24 and Vertical Termination | ||
| ||
| Page |
Figure 40
HORIZONTAL TERMINATION
NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior position on the building.
WARNING: Termination cap must be positioned so that arrow is pointing up.
Attach the termination cap with the four wood screws provided. Before attachment of the termination, run a bead of silicone sealant rated above 250°F on its outside edge too, so as to make a seal to the exterior wall.
NOTE: Wood screws can and should be replaced with appropriate fasteners for use on stucco, brick, concrete or other types of siding.
CAUTION: If exterior walls are finished with vinyl siding, (or materials that could become discolored or warp) it is necessary to install the vinyl siding standoff
Vinyl siding standoff |
|
termination and the exterior wall. (See Figure 42) This horizontal |
|
vent termination bolts onto the flat portion of the vinyl siding |
|
standoff, so an air space will exist between the wall and the |
|
termination cap. | Figure 42 |
|
Page 24 |