Empire Comfort Systems DVP42FP7, DVP48FP3, DVP48FP9, DVP42FP9, DVP48FP7 Blower Motor, Blower Wheels

Page 47

FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION

Attention: Install blower assembly before connecting gas inlet supply line

Note: Junction box on right side of fireplace must be pre-wired at time of fireplace installation for use with blower assembly. It is recommended that an ON/OFF wall switch be installed that will activate the power supply to the furnace by a qualified electrician.

1.If installed, turn OFF gas supply to fireplace.

2.If applicable, turn OFF electric supply to fireplace.

3.Lower bottom louver on fireplace.

4.Refer to page 48, "Junction Box Wiring Installation Instructions" to complete wiring of junction box.

Attention: If installed, do not damage gas inlet supply line when blower assembly is inserted into fireplace. If necessary, remove gas inlet supply line.

Wiring

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Blower Motor

The blower motor does not have oiling holes. Do not attempt to oil the blower motor.

Blower Wheels

The blower wheels will collect lint and could require periodic cleaning. If the air output decreases or the noise level increases, it indicates a dirty blower wheel. Remove fan and clean blower wheels.

Warning: Unplugging of blower accessory will not stop the heater from cycling. To turn off gas to the heater (millivolt model): push in gas control knob slightly and turn clockwise to "OFF." Do not force. To turn off gas on direct ignition model, turn gas line valve to "OFF."

5.Insert blower assembly into interior, bottom of fireplace. Position blower assembly behind gas valve, align notch on back of blower assembly with center screw on fireplace back and push blower assembly against fireplace back. The magnets on the back and bottom of blower assembly will sufficiently hold blower assembly in place.

6.Position speed control box to the right of gas valve. Attach speed control box to bottom of fireplace. The magnets on bottom of speed control box will sufficiently hold speed control box in place.

7.With base (flush face) of fan control switch facing upward, insert base of fan control switch under the mounting tabs on valve bracket. The base (flush face) of fan control switch must be in contact with bottom of firebox.

8.Insert power cord plug into junction box.

9.Close bottom louver on fireplace.

10.Installation of FBB4 optional variable speed blower assembly is completed.

SEE NOTE*

 

JUNCTION BOX

FAN KIT

SPEED CONTROL

 

VALVE BRACKET

 

FAN SWITCH

 

 

SWITCH HOLDER

(TOP OF VALVE BRACKET)

*Note: Refer to Junction Box wiring instructions on page 34 and 48 for proper operation.

17375-6-0705

Page 47

Image 47
Contents Installation Instructions Table of Contents Important Safety Information LP-GAS Warning Odor Safety Information for Users of LP GASIntroduction Fireplace Dimensions SpecificationsClearances Figure Mantel Chart FigureClearances Locating FireplaceChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Converting flue take-off to rear venting Rear Vent ConversionVent Systems Vent Pipe Clearance InstallationFraming and Finishing Finishing Figures 12 Flush Mount Mantel Installation FigureFraming Figure VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationCombustible Surround Installation Vent Runs Figures 14, 15, 16, 17Model VERTICAL, 90 Elbow toExample a Venting Graph Dimensions in FeetVenting Fireplace TOP To Use the Vent Graph FigureVenting Fireplace TOP Below Grade InstallationFireplace Hard Elbow Dimensions Series DVP42FP Examples TOP Vent RUN Theunit Caps Venting Fireplace RearExamples Rear Vent RUN Information on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Vent System Identification Installing Vent Components FigureFraming and Finishing Installing Support Brackets FigureInstalling Firestops Figures 38, 39, 40 See Horizontal Termination Page 24 and Vertical Termination Horizontal TerminationDVVK-5F Flex Vent Instructions Determining Minimum Vent Height Above the Roof General MaintenanceInstalling the Vent System in a Chase Vertical TerminationVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Placement 3 LOG SET Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions For Your Safety Read Before LightingGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationElectrical Connection Figure Intermittent Pilot Operating InstructionsWhat to do if YOU Smell GAS For Your Safety Read Before LightingTrial for Ignition S8600H Intermittent Ignition Module SpecificationsCheckout OperationMain Burner Operation Safety LockoutARC Length Action Ignition System Checks Check ignition cable. Make sureIntermittent Pilot Troubleshooting Thermopiles Transmitter SignalFunctions Receiver Shutdown of BurnerRF Transmitter Functions Wiring Diagram with Blower RF Standing Pilot Lighting Instructions Please Note Maintenance and ServiceParts View Parts List Blower Wheels Blower MotorVolt AC Optional Brick Liner Installation Instructions Junction BOX Wiring Installation InstructionsFBB4 AccessoriesService Notes HOW to Order Repair Parts Service Notes