CLEARANCES
Clearance to Combustibles
Back | 0" (0 mm) |
Side | 0" (0 mm) |
Floor | 0" (0 mm) |
Top | 0" (0 mm) |
Top Framing Edge | 3" (76 mm) |
SEE MANTLE CHART FOR | |
MAXIMUM MANTLE DEPTH |
Mantel Chart (Figure 3)
SEE MANTLE CHART FOR MINIMUM HEIGHT OF MANTLE ABOVE UNIT
FINISHED WALL (COMBUSTIBLE)
TOP FRAMING
LEDGE
GLASS FRONT
2" x 4" HEADER
STAND OFF 3" (76 mm) HEIGHT ABOVE TOP OF FIREPLACE
3"
NAILING
FLANGES
Figure 3
Clearances (Figure 4)
Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is 6".
(914mm)
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. The flow of heat can ignite combustibles.
Figure 4
LOCATING FIREPLACE
Note: Island (C) and Room Divider
(D)installation is possible as long as the horizontal portion of the vent system (H) does not exceed 20 feet with a minimum vertical run of 8 feet. See details in Venting Section.
When you install your Direct Vent Fireplace in (D) Room divider or
(E)Flat on wall corner positions, a minimum of 6 inches clearance must be maintained from the perpendicular wall and the front edge of the appliance.
CORNER | CABINET |
INSTALLATION | INSTALLATION |
ISLAND | FLUSH WALL |
INSTALLATION | INSTALLATION |
ANGLED CORNER |
|
INSTALLATION | ROOM DIVIDER |
| INSTALLATION |
Figure 5
Page 7 |