Empire Comfort Systems DVP42FP7, DVP48FP3, DVP48FP9, DVP42FP9, DVP48FP7 RF Transmitter Functions

Page 41

RF TRANSMITTER FUNCTIONS

FIRST USE OF TRANSMITTER

Status

 

Action

Begin communication between transmitter and receiver/valve.

 

Move LOCAL/REMOTE Switch to LOCAL position for at least

 

 

two seconds; then move switch to the REMOTE position.

Transmit unique code.

 

Press Fan or Flame key within 30 seconds.

 

 

 

Confirm recognition between transmitter and receiver/valve.

 

Observe LED turns on for one second.

 

 

 

Chose Remote or Local operation.

 

Move LOCAL/REMOTE switch to LOCAL or leave in REMOTE.

 

 

 

Operation in the Remote Position

AUTO Mode

With the control in the AUTO mode, the flame in the main burner will turn on, off, or change height based on the heat needed to maintain the set temperature.

Status

 

Action

Set to AUTO.

 

Press MODE button until mode is AUTO.

 

 

 

Change set temperature.

 

Press UP or DOWN key to change set temperature.

 

 

 

Flame.

 

Automatically changes.

 

 

 

Fan.

 

Automatically changes.

To Set Delay Timer.

 

Press TIME key followed by either an UP or DOWN arrow key.

 

 

 

CAUTION

Properly Damage Hazard.

Excessive heat can cause property damage.

In AUTO mode, the main burner will cycle indefinitely to maintain the set temperature. Keep the transmitter in a heated living space to make sure that the main burner is not on continuously.

On Mode

When the control is in the ON mode, the flame and fan levels and the delay timer are changed with the UP and DOWN arrow keys.

Status

 

Action

Set to ON.

 

Press MODE button until mode is ON.

 

 

 

Flame.

 

Press FLAME button and press UP or DOWN arrow key to change

 

 

flame height.

Fan.

 

Press FAN button and press UP or DOWN arrow key to change fan

 

 

speed.

Delay Time.

 

Press DELAY TIMER button and press UP or DOWN key to

 

 

change timer.

OFF Mode

 

Press MODE until mode is OFF.

The flame in the main burner will turn off and the room

 

 

temperature will be displayed in the remote window.

 

 

Operation in the LOCAL Mode.

NOTE: Remote/Local switch on the receiver/valve must be in the LOCAL position.

FAN

 

In LOCAL mode, to turn flame on/off, rotate manual knob from

Flame height and fan speed both go to the highest position.

 

ON to PILOT position.

Other Functions:

 

 

Change between Fahrenheit and Celsius temperature units.

 

Press UP and DOWN arrow keys at the same time and hold for at

 

 

least three seconds.

Fan Override during AUTO Mode.

 

Press FAN button, and press UP or DOWN arrow key to change

 

 

the fan speed.

 

 

 

Disable thermostat function in the AUTO Mode

 

Press the TIME, DOWN and FLAME arrow keys at the same time

 

 

and hold for at least three seconds.

 

 

 

17375-6-0705

Page 41

Image 41
Contents Installation Instructions Table of Contents Important Safety Information LP-GAS Warning Odor Safety Information for Users of LP GASIntroduction Fireplace Dimensions SpecificationsClearances Mantel Chart FigureLocating Fireplace Clearances FigureChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Converting flue take-off to rear venting Rear Vent ConversionVent Systems Vent Pipe Clearance InstallationFraming and Finishing Finishing Figures 12 Flush Mount Mantel Installation FigureFraming Figure Combustible Surround Installation Flush Wall InstallationVent Runs Figures 14, 15, 16, 17 VERTICAL, 90 Elbow with Horizontal TerminationModel VERTICAL, 90 Elbow toVenting Fireplace TOP Venting Graph Dimensions in FeetTo Use the Vent Graph Figure Example aVenting Fireplace TOP Below Grade InstallationFireplace Hard Elbow Dimensions Series DVP42FP Examples TOP Vent RUN Theunit Caps Venting Fireplace RearExamples Rear Vent RUN Information on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Vent System Identification Installing Vent Components FigureFraming and Finishing Installing Support Brackets FigureInstalling Firestops Figures 38, 39, 40 See Horizontal Termination Page 24 and Vertical Termination Horizontal TerminationDVVK-5F Flex Vent Instructions Installing the Vent System in a Chase General MaintenanceVertical Termination Determining Minimum Vent Height Above the RoofVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Placement 3 LOG SET Millivolt System Operating InstructionsInitial Lighting Pilot Flame FigureTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions For Your Safety Read Before LightingFrequent pilot outage problem Standing Pilot TroubleshootingPilot and main burner extinguish while in operation Glass sootsElectrical Connection Figure Intermittent Pilot Operating InstructionsWhat to do if YOU Smell GAS For Your Safety Read Before LightingCheckout S8600H Intermittent Ignition Module SpecificationsOperation Trial for IgnitionMain Burner Operation Safety Lockout ARC Length Action Ignition System Checks Check ignition cable. Make sureIntermittent Pilot Troubleshooting Functions Transmitter SignalReceiver Shutdown of Burner ThermopilesRF Transmitter Functions Wiring Diagram with Blower RF Standing Pilot Lighting Instructions Please Note Maintenance and ServiceParts View Parts List Blower Wheels Blower MotorVolt AC Optional Brick Liner Installation Instructions Junction BOX Wiring Installation InstructionsFBB4 AccessoriesService Notes HOW to Order Repair Parts Service Notes