Empire Comfort Systems DVP48FP7, DVP48FP3, DVP48FP9, DVP42FP9 Intermittent Pilot Troubleshooting

Page 39

INTERMITTENT PILOT TROUBLESHOOTING (continued)

S8600H TROUBLESHOOTING GUIDE

START

Turn gas supply off Turn thermostat to call for heat.

Power to module. (24VAC nominal)

Yes

Spark across ignitor/sensor gap.

Yes

Turn gas supply on.

Pilot burner lights?

Yes

Note: Before troubleshooting, familiarize yourself with the startup and checkout procedure.

Check line voltage power, low voltage transformer limit control,

No

thermostat and wiring.

 

 

 

 

 

 

 

 

 

 

 

 

Pull ignition lead and

 

 

 

 

 

check spark at ignition

No

Replace module.

No

 

 

 

stud.

 

 

 

 

 

 

 

 

 

 

Spark okay?

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

Check ignition cable, ground wiring, ceramic insulator, and gap, and correct.

Check boot of the ignition cable for signs of melting or buckling. Take protective action to shield cable and boot from excessive temperatures.

Check that all manual gas valves are open. Supply tubing

No

And pressures are good, and pilot burner orifice is not blocked.

 

Check electrical connections between module and pilot

 

 

Operator on gas control.

 

 

Check for 24 VAC across PV - MV/PV terminals on module.

 

 

If voltage is okay, replace gas control. If not, replace module.

Spark stops when pilot is lit?

No

Note: If S8600H goes into lockout, reset system.

Yes

Main burner lights?

Yes

System runs until call for heat ends?

Yes

Call for heat ends.

System shuts off?

Check continuity of ignition cable and ground wire.

Check that pilot flame covers electrode.

Adjust pilot flame current. Minimum signal should read 1.0 microamp.

If problem persists, replace module.

 

 

 

Check for 24 VAC across MV-MV/PV terminals. If no voltage,

 

No

replace module.

 

 

 

Check electrical connections between module and gas control.

 

 

 

 

 

 

If okay, replace gas control.

 

 

 

 

 

 

 

 

 

 

 

Note: If S8600H goes into lockout, reset system.

 

 

 

 

No

 

Check continuity of ignition cable and ground wire. Note: If

 

 

 

 

 

 

ground is poor or erratic, shutdowns may occur occasionally

 

 

 

 

 

 

even though operation is normal at the time of checkout.

 

 

 

If checks are okay, replace module.

 

 

 

 

 

 

 

 

 

 

 

Check for proper thermostat operation.

 

No

 

Remove MV lead at module: If valve closes, recheck

 

 

 

 

 

 

thermostat and wiring. If not, replace gas control.

 

 

 

 

 

 

 

Troubleshooting ends.

Repeat procedure until troublefree operation is obtained.

17375-6-0705

Page 39

Image 39
Contents Installation Instructions Table of Contents Important Safety Information LP-GAS Warning Odor Safety Information for Users of LP GASIntroduction Fireplace Dimensions SpecificationsClearances Figure Mantel Chart FigureClearances Locating FireplaceInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Rear Vent Conversion Vent SystemsConverting flue take-off to rear venting Installation Framing and FinishingVent Pipe Clearance Flush Mount Mantel Installation Figure Framing FigureFinishing Figures 12 VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationCombustible Surround Installation Vent Runs Figures 14, 15, 16, 17Model VERTICAL, 90 Elbow toExample a Venting Graph Dimensions in FeetVenting Fireplace TOP To Use the Vent Graph FigureVenting Fireplace TOP Below Grade InstallationFireplace Hard Elbow Dimensions Series DVP42FP Examples TOP Vent RUN Theunit Caps Venting Fireplace RearExamples Rear Vent RUN Vertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Vent Components FigureInstalling Support Brackets Figure Installing Firestops Figures 38, 39, 40Framing and Finishing See Horizontal Termination Page 24 and Vertical Termination Horizontal TerminationDVVK-5F Flex Vent Instructions Determining Minimum Vent Height Above the Roof General MaintenanceInstalling the Vent System in a Chase Vertical TerminationVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Placement 3 LOG SET Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions For Your Safety Read Before LightingGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationElectrical Connection Figure Intermittent Pilot Operating InstructionsWhat to do if YOU Smell GAS For Your Safety Read Before LightingTrial for Ignition S8600H Intermittent Ignition Module SpecificationsCheckout OperationMain Burner Operation Safety LockoutARC Length Action Ignition System Checks Check ignition cable. Make sureIntermittent Pilot Troubleshooting Thermopiles Transmitter SignalFunctions Receiver Shutdown of BurnerRF Transmitter Functions Wiring Diagram with Blower RF Standing Pilot Lighting Instructions Please Note Maintenance and ServiceParts View Parts List Blower Wheels Blower MotorVolt AC Optional Brick Liner Installation Instructions Junction BOX Wiring Installation InstructionsFBB4 AccessoriesService Notes HOW to Order Repair Parts Service Notes