HOW TO CORRECT PROBLEMS IN THE MACHINE

PROBLEM

CAUSE

ACTION

The machine does not remove all

The squeegee is up

Lower the squeegee.

the water from the floor.

 

 

The vacuum tank is full.

Drain the tank.

 

 

 

 

 

The screen filter is dirty.

Clean the screen filter.

 

 

 

 

There is an obstruction or damage in the

Remove the obstruction or repair the

 

squeegee, squeegee hose or standpipe.

damage.

 

The vacuum motor is not running.

Check for tripped breaker. Have an

 

 

authorized service person make repairs.

 

The squeegee hose is disconnected.

Connect the hose.

 

 

 

 

The squeegee blade is damaged, worn, or

Turn or replace the squeegee blade.

 

incorrectly installed.

Correctly install the squeegee blade.

 

The squeegee pressure is not correctly

Adjust the pressure of the squeegee.

 

adjusted.

 

 

The gaskets on the cover of the recovery

Replace the gaskets.

 

tank are damaged.

 

The batteries do not give the normal

The battery terminals are dirty or damaged.

Clean the terminals and connectors.

running time.

 

Replace the damaged cables. Charge the

 

 

batteries.

 

The electrolyte level is too low.

Add distilled water to each cell and charge

 

 

the batteries.

 

The batteries are not fully charged.

Charge the batteries for a full 16 hour

 

 

charge.

 

The charger is damaged.

Have an authorized service person repair

 

 

the charger.

 

The battery is defective.

Check voltage of each cell while

 

 

discharging.

 

The batteries are disconnected.

Connect the batteries.

 

 

 

The cleaning is not even.

The scrub brushes or pads are worn.

Replace the scrub brushes or pads.

 

 

 

 

There is damage to the brush assembly,

Have an authorized service person make

 

casters or the solution valve.

the needed repairs.

 

The brush motors are not running.

Check for tripped breaker, reset. Check for

 

 

loose connections.

 

The solution level is low.

Fill the solution tank.

 

 

NOTE: If the motors continue to stop

 

 

consult an authorized service person.

The machine does not run.

The machine loses power.

Reset the circuit breaker.

 

 

Check wire connection to traverse motor.

 

 

Replace the fuses.

 

 

Check the batteries connections.

 

 

Check parking brake overide lever

 

 

position (if installed)

 

 

NOTE: If the motors continue to stop,

 

 

consult an authorized service person.

-28- FORM NO. 70935A

Nilfisk ALTO Operator's Manual - SCRUBTEC 770 / 784 / 795

Image 28
Contents Operators Manual Read this ManualTable of Contents Operator Safety Instructions Operator Safety Instructions Introduction Machine SpecificationsSpecifications ModelProcedures for Transporting How To Put The Machine In a Van Or TruckSymbols Used on Scrubtec 770, 784 Symbols Used on71017A use Increase Brush Pressure Switch See Figure #1, Item D Charge / Battery Meter Solo See Figure #1, Item H1D a Machine Control Panel 770L, 784L & 795L K J H Display Screens for Scrubtec 770L, 784L, 795L Machine Controls & Features Figure #4HOW to Prepare the Machine for OPERA- Tion How To Install The BatteriesHOW to Prepare the Machine for Operation Battery MaintenanceHow To Charge The Batteries Figure #How To Remove The Brushes Or Pad Drivers Figure #9Reprogramming One Touch Figure #11How To Operate the Squeegee S Class models only How to Fill The Solution TankHow To Traverse Machine How to Clean a FloorThese Maintenance Procedures Must Be Done Every Day How to Clean a Very Dirty FloorDo These Procedures When You Begin Your Work Period Do These Procedures When You End Your Work Figure #21Figure #24 Figure #25Maintenance For The Squeegee How To Adjust The SqueegeeAdjusting Squeegee Pressure Adjusting Squeegee TiltAdjusting Squeegee Blades How to Clean the Solution LineHOW to Correct Problems in the Machine Scrubtec 770L / 784L / 795L WB Common Error Codes Form no a Nilfisk Alto Operators Manual Scrubtec 770 / 784 Section 31 30 29 Ref. No Qty Description Nilfisk Alto Scrubtec 770 / 784 Recovery Tank Assembly 12/09 Scrubtec 770 / 784 Form no a Nilfisk Alto Operators Manual Scrubtec 770 / 784 Electrical Panel Assembly / Solo Speed Controller 12/09 Form no a Nilfisk Alto Operators Manual Scrubtec 770 / 784 Scrubtec 770 S / 784 S / 795 S Form no a Nilfisk Alto Operators Manual Scrubtec 770 / 784 Electrical Panel Assembly Parts List 2/07 18A 920208 Nut, 1/4-20 962968 Screw, 10-24 x 1/2 40749A Form no a Nilfisk Alto Operators Manual Scrubtec 770 / 784 Scr 6-32 x Form no a Nilfisk Alto Operators Manual Scrubtec 770 / 784 Ref. No Qty Description Nilfisk Alto Scrubtec 770 Squeegee Assembly 12/09 Scrubtec 770 Scrubtec Squeegee Assembly 12/09 Ref. No Qty Description Nilfisk Alto Scrubtec 770 / 784 Traverse System Assembly 2/05 Ref. No Qty Description Nilfisk Alto Operators Manual Scrubtec 770 / 784 Nilfisk Alto Operators Manual Scrubtec 770 / 784 Nilfisk Alto Scrubtec 770 / 784 Brush Motor #45036A 2/05 Nilfisk Alto Operators Manual Scrubtec 770 / 784 Permanent Magnet Motor MFG. in USA PN 59116A Parking Brake Spare PartsBrushes PAD DriversNilfisk Alto Operators Manual Scrubtec 770 / 784 Form no a Nilfisk Alto Operators Manual Scrubtec 770 / 784 Electrical Schematic 9/05 Page Page Year of Affixing the CE marking Nilfisk Alto Limited U.S. Warranty Always use genuine Nilfisk Alto Parts for repair