Mitsubishi Electronics PUHY-HP-THMU-A installation manual Outdoor model P144 ~ P192

Page 8

[Outdoor model : P144 ~ P192]

unit 1

unit 2

 

A

 

A

A1

A2

 

 

 

A

 

E

B

 

 

B

a

C

C

b

C

D

c

C

d

C

e

C

unit 1

unit 2

A

A

A1

A2

A

 

 

F

 

B

 

 

 

 

E

 

 

 

 

a

b c

d

e D

C

C

C

C

C

 

 

GB

A Outdoor unit

B 1st branch

C Indoor unit

D Cap

E Outdoor Twinning Kit

F Header

* The total length of A1 and A2 is less than 10 m [32 ft].

A

(Unit: mm [in])

Outdoor model

Unit combination

 

A

 

A1

 

A2

 

unit 1

unit 2

Liquid pipe

Gas pipe

Liquid pipe

Gas pipe

Liquid pipe

Gas pipe

P72

-

-

ø12.7 [1/2] Brazed

ø19.05 [3/4] Brazed

-

-

-

-

 

 

 

 

 

 

 

 

 

P96

-

-

ø12.7 [1/2] Brazed

ø22.2 [7/8] Brazed

-

-

-

-

P144

P72

P72

ø15.88 [5/8] Brazed

ø28.58 [1-1/8] Brazed

ø9.52 [3/8] Flare

ø19.05 [3/4] Brazed

ø9.52 [3/8] Flare

ø19.05 [3/4] Brazed

P192

P96

P96

ø15.88 [5/8] Brazed

ø28.58 [1-1/8] Brazed

ø9.52 [3/8] Flare

ø22.2 [7/8] Brazed

ø9.52 [3/8] Flare

ø22.2 [7/8] Brazed

 

B, C, D

 

 

 

(Unit: mm [in])

 

 

 

 

 

 

 

Total capacity of indoor units

 

Liquid pipe

 

Gas pipe

 

~ 54

 

 

ø9.52 [3/8]

 

ø15.88 [5/8]

 

55 ~ 72

 

 

ø9.52 [3/8]

 

ø19.05 [3/4]

 

73 ~ 108

 

 

ø9.52 [3/8]

 

ø22.2 [7/8]

 

109 ~ 144

 

 

ø12.7 [1/2]

 

ø28.58 [1-1/8]

 

145 ~ 234

 

 

ø15.88 [5/8]

 

ø28.58 [1-1/8]

 

 

 

 

 

 

a, b, c, d, e

 

 

 

(Unit: mm [in])

 

 

 

 

 

 

 

 

Model number

 

Liquid pipe

 

Gas pipe

 

06, 08, 12, 15, 18

 

ø6.35 [1/4]

ø12.7 [1/2]

 

24, 27, 30, 36, 48, 54

 

ø9.52 [3/8]

ø15.88 [5/8]

 

72

 

ø9.52 [3/8]

ø19.05 [3/4]

 

96

 

ø9.52 [3/8]

ø22.2 [7/8]

 

 

 

 

 

 

 

Precautions for outdoor unit combinations

Refer to [Fig. 9.2.2] for the positioning of twinning pipes.

[Fig. 9.2.2]

Downstream unit model total

 

 

 

Joint

 

 

~ 72

 

 

 

CMY-Y102S-G2

 

 

73 ~ 144

 

 

 

CMY-Y102L-G2

 

 

145 ~ 234

 

 

 

 

CMY-Y202-G2

 

 

The 1st branch of P144 ~ P234

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-Branch header

 

8-Branch header

 

10-Branch header

(Downstream indoor

 

(Downstream indoor

 

(Downstream indoor

<

 

<

144)

 

unit model total

<

234)

unit model total = 72)

 

unit model total =

 

=

CMY-Y104-G

 

CMY-Y108-G

 

 

CMY-Y1010-G

 

 

 

 

 

 

Outdoor model

 

 

Outdoor Twinning Kit

 

 

P144 ~ P192

 

 

CMY-Y100VBK2

 

 

 

 

 

 

 

 

 

 

 

<A> Make sure the pipes from the twinning pipe to the outdoor unit are sloped downwards (towards the twinning pipes).

A C C

FB F

<B> When the piping on the outdoor unit side (from the twinning pipe) exceeds 2 m [6 ft], ensure a trap (gas pipe only) within 2 m [6 ft]. Make sure the height of the trap is 200 mm [7-7/8 in] or more.

If there is no trap, oil can accumulate inside the pipe, causing a shortage of oil and may damage the compressor.

(Unit: m [ft])

F

C

2[6]

D

E

F

C

8

Image 8
Contents Outdoor Unit Contents Safety precautionsBefore installation Before installation relocation electri- cal workAbout the product Before starting the test runSpecifications Space required for unit installation and operationCombination of outdoor unit Parts included listBe very careful when carrying/moving the product Transporting the unitInstallation of unit Refrigerant piping installationInstallation Outlet Inlet Inlet InletRefrigerant piping system Precautions for outdoor unit combinations Outdoor model P144 ~ P192Additional refrigerant charge Calculation of additional refrigerant chargeAppropriate tightening torque Cap N·m /kg·cm Shaft N·m /kg·cm Size of hexagonalWrench mm Ø9.52 3/8 22/220 Ø12.7 1/2 20/200Airtight test, evacuation, and refrigerant charging Airtight testOnly use refrigerant R410A EvacuationTemperature Resistance Thermal insulation of refrigerant pipingOutdoor Water-proof hemp cloth + Zinc plate + Oily paint Refrigerant ChargingWiring transmission cables Wiring examples Examples of transmission cable wiringUnnecessary address setting Necessary main/sub setting GroundSequence with the IC Main Automatically identified. *1Thickness of wire for main power supply, on/off capacities Wiring of main power supply and equipment capacitySchematic Drawing of Wiring Example Test run/Typical unit operation Rating plate informationPrécautions de sécurité Avant installation et travaux électriquesContenu Avant linstallation Avant linstallation déménagement travaux électriquesPropos du produit Avant de commencer lessaiEspace requis pour installer et utiliser lunité Combinaison dunités extérieuresSpécifications Liste des pièces inclusesFaites très attention en portant/déménageant le produit En cas dinstallation collective FigTransport de lunité Installation de lunité Installation de la tuyauterie du frigorigèneInstallation Mise en gardeModèle extérieur P72 P96 Système de tuyauterie du frigorigèneNutilisez jamais la tuyauterie du frigorigène existante Modèle extérieur P144 P192 Précautions pour les combinaisons dunités extérieuresCharge supplémentaire de frigorigène Calcul de la charge supplémentaire de frigorigèneCouple de serrage approprié Utilisez uniquement le frigorigène R410A Test dherméticité, évacuation et chargement de frigorigèneTest dherméticité Chargement du frigorigène Isolation thermique de la tuyauterieDu frigorigène Raccordement des câbles de transmission 1 Télécommande M-NET Exemples de câblageÉlévateur du niveau des signaux de transmission ~208-230V L1, L2, L3 Terre ~208-230V L, N Schéma du câblage exemple FigInformations de la plaque signalétique Essai de fonctionnement/Fonctionnement type dune unitéPage Page WT05234X02