2. CONNECTION TO ELECTRICITY SUPPLY
WARNING: This appliance must be earthed, do not earth this appliance to the gas supply piping.
This appliance must be connected to a
i)Replaced totally by a longer cable at least 0.75mm² nominal cross sectional area (24/0.2).
ii)Extended by using a B.E.A.B. approved
DO NOT EXTEND THE CABLE USING PLASTIC OR CERAMIC CONNECTION TERMINAL BLOCKS AND/OR INSULATION TAPE.
If the supply cable is replaced it is recommended that the ends of the new cable all be cut to the same length 60mm, any excess wire being stored inside the mains terminal see Fig.5.
Should the supplied cable be required to be threaded through small apertures in the cabinets it can be removed from the mains inlet terminal block see Fig.5.
If the supplied plug is cut off dispose of it safely as it will be a shock hazard if inserted into a 13 amp socket elsewhere in the house.
To fit a 3 pin 13 amp plug to the end of the appliance cable (Fig.6). Connect the wires as follows:
BROWN to the live terminal. | GREEN AND YELLOW | |
BLUE to the neutral terminal. | ||
| ||
GREEN and YELLOW to the earth terminal. |
|
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is GREEN and YELLOW must be connected to the terminal in the plug which is marked with
FIG.5
3 AMP
the letter 'E' or by the earth symbol or coloured GREEN or GREEN and YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is marked with the letter 'N' or coloured black.
BLUE
BROWN
FIG.6
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter 'L' or coloured RED.
FIT A 3 AMP FUSE TO THE PLUG FUSE HOLDER
42